HomeMy WebLinkAboutA512 - JULIET BALCONY DETAILS3'-6"1 1/2" BALCONY CENTERED ON OPENING 7'-5" 1 1/2" 1 1/2" SQUARE HORIZONTAL RAIL 1 1/2" SQUARE HORIZONTAL RAIL 3/4" SQUARE INTERMEDIATE PICKET 1 1/2" SQUARE VERTICAL POST ROUGH OPENING 6'-3 1/2" FINISH FLOOR 3"JULIET BALCONY RAILING SYSTEM STEEL CHANNEL MOUNTED TO FACE OF SIDING BELOW RAILING FACE OF FINISH -BRICK OR SIDING/ TRIM REF. ELEVATIONS 3"7 1/2" 7 1/2" 7 1/2" 7 1/2" 5 1/2" 5 1/2" 5/4x12 FIBER CEMENT TRIM T-PLATES FINISH FLOOR PREPRIMED STEEL JULIET BALCONY SYSTEM CONTINUOUS SEALANT AROUND PLATE AT TRIM GALVANIZED STEEL T-SHAPE ANCHORING PLATE TO MOUNT JULIET BALCONY RAILING FOR SECURE CONNECTION TO MEET ALL LOADING REQUIREMENTS, ANCHOR PLATE TO STUDS. VERIFY WITH STRUCTURAL SELF-HEALING FLASHING OVER AIR/ MOISTURE BARRIER INSTALLED PRIOR TO DOOR TRIM PER DETAILS AND BENEATH ANCHOR PLATES 5/4X12 FIBER CEMENT TRIM WEATHER BARRIER SELF-ADHERED MEMBRANE BEHIND FIBER CEMENT TRIM WEATHER BARRIER PREPRIMED STEEL JULIET BALCONY RAILING SYSTEM SCHEDULED IN-SWING DOOR FINISH FLOOR 3"42" MIN. TO TOP OF RAIL4 1/2"3'-0" 3/4" 4" 25 A615 Sim 42" MIN. TO THE TOP OF RAIL PREPRIMED STEEL JULIET BALCONY RAILING SYSTEM SCHEDULED IN-SWING DOOR FINISH FLOOR 4 1/2"3'-0" 3/4" 4" 3" 27 A615 Sim8"3" BRICK VENEER GALVANIZED STEEL T-SHAPE ANCHORING PLATE TO MOUNT JULIET RAILING FOR SECURE CONNECTION TO MEET ALL LOADING REQUIREMENTS, INSTALL LOADING BRICK, ANCHOR PLATE TO STUDS. REF. STRUCTURAL BALCONY RAILING SYSTEM ANCHORING PLATE AT INSIDE FACE OF RAILING POSTS TO CONCEAL ANCHORING PLATE PENETRATION 1/2" SEALANT JOINT AND BACKER ROD CONTINUOUS AROUND PLATE PENETRATION SELF-ADHERED FLASHING OVER GALVANIZED ALUM. SADDLE FLASHING AT PLATE PENETRATIONS PRE-FINISHED STEEL JULIET RAILING SYSTEM 1X2 FIBER CEMENT TRIM CAULK PREPRIMED STEEL JULIET BALCONY RAILING SYSTEM 1/2" SEALANT JOINT AND BACKER ROD CONTINUOUS AROUND PLATE PENETRATION FINISH FLOOR GALVANIZED STEEL T-SHAPE ANCHORING PLATE TO MOUNT JULIET RAILING FOR SECURE CONNECTION TO MEET ALL LOADING REQUIREMENTS, INSTALL LOADING BRICK, ANCHOR PLATE TO STUDS. VERIFY WITH STRUCTURAL. SELF-ADHERED FLASHING OVER GALVANIZED ALUM. SADDLE FLASHING AT PLATE PENETRATIONS 25 A512 Sim 50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Seal Issued / RevisedDate # Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site.9/3/2021 2:45:38 PM C:\Revit Projects\18066-Corner Carmel-CENTRAL-19_smatsumotoBZ9SZ.rvt LRK Project Number: 01.18066.00 A512 JULIET BALCONY DETAILS The Corner Carmel, IN VWB SWMThe Corner Carmel, IN •01.18066.001685 E. 116th Street, Carmel, IN SCALE: 1" = 1'-0" 19 PLAN/ ELEVATION DETAIL -JULIET BALCONY RAILING SCALE: 1 1/2" = 1'-0" 15 JULIET SECTION AT WALL -SIDING SCALE: 1 1/2" = 1'-0" 17 JULIET SECTION AT DOOR -SIDING SCALE: 1 1/2" = 1'-0" 29 JULIET SECTION AT DOOR -BRICK SCALE: 3" = 1'-0" 25 PLAN DETAIL AT JULIET BALCONY ANCHOR SCALE: 1 1/2" = 1'-0" 27 JULIET SECTION AT ANCHOR -BRICK 06.16.21 Permit Set B 08.20.21 IFC Set C 09.01.21 IFC Set 11/15/21