HomeMy WebLinkAboutCorner Building A CDRELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm.
This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans.
Use Internet Browser to View this report, other browsers are not compatible to view this report
Page 1/2
CONSTRUCTION DESIGN RELEASE
State Form 41191 (R9/5-98)
Report Printed on:September 17, 2021
Project number Release date
423560 08/25/21
Construction type Occupancy classification
Scope of release
I-A, V-A, SPK A-2, A-3, B, R-2
Type of release
Project name
Street address
City County
ARCH ELEC MECH
PLUM STR
Standard
The Corner - Bldg A
1685 E 116 St
CARMEL HAMILTON
To: Owner / Architect / Engineer
LRK, Inc
Victor W Buchholz AR11800012
50 South B.B. King Blvd
Suite 600
Memphis TN 38103
Note :(A1A & A1B): In accordance with the affidavit sworn under penalties of perjury in the application for construction design release the plans
and specifications filed in conjunction with this project shall comply with all of the applicable rules and laws of Fire Prevention and Building Safety
Commission. Providing false information constitutes an act of perjury, which is a Class D felony punishable by a prison term and a fine up to $10,000.
The plans, specifications and application submitted for the above referenced project have been reviewed for compliance with the applicable rules of
the Fire Prevention and Building Safety Commission. The project is released for construction subject to, but not necessarily limited to, the conditions
listed below. THIS IS NOT A BUILDING PERMIT. All required local permits and licenses must be obtained prior to beginning construction work. All
construction work must be in full compliance with all applicable State rules. Any changes in the released plans and/or specifications must be filed with
and released by this Office before any work is altered. This release may be suspended or revoked if it is determined to be issued in error, in violation
of any rules of the Commission or if it is based on incorrect or insufficient information. This release shall expire by limitation, and become null and
void, if the work authorized is not commenced within one (1) year from the above date.
CONDITIONS:
14B
4G0603AE
4G05A
4G05
4G0603AE1
4G0618AK
4G0607AT
This project has been reviewed under the 2014 Indiana Building Code.
Detailed plans and specifications of the fire suppression system shall be filed with the required
application and appropriate fees in accordance with 675 IAC 12-6-3(a), 675 IAC 12-6-7(g)(17), and
675 IAC 13-1-8. (N.F.P.A. 13) NOTE: Applicable to First Floor (Podium)
The Fire Prevention and Building Safety Commission has granted one or more variances which
apply to this project. 21-04-41 (510.2, Cond. 7; 1007.2.1; 716.5; 714.4.1.2; 3004.1 - 2014
IBC;and 2-27 (a) - ISPC)
All conditions set forth by the Indiana Fire Prevention and Building Safety Commission on variance
submissions shall be considered part of the release documents and do not apply to future additions
or alterations of this structure in accordance with 675 IAC l2-5.
Detailed plans and specifications of the fire suppression system shall be filed with the required
application and appropriate fees in accordance with 675 IAC 12-6-3(a), 675 IAC 12-6-7(g)(17), and
675 IAC 13-1-25. (N.F.P.A. 13R) NOTE: Applicable in R-2; above Podium.
NOTE: This review includes Building A, only.
NOTE: This project release is for the building shell only, where finish of one or more tenant spaces
has not been shown on plans. Tenant space finish shall be filed as a new project in accordance
with 67 IAC 12-6-6 before commencing work.
"Alternates" to plans are not part of this release and will only be considered as part of this project if
submitted as addenda in accordance with 675 IAC 12-6-l8. Such design changes shall not include
increases in project height and / or area.
Plans for public swimming pools shall be submitted with the appropriate Swimming Pool Application
(signed by the owner and design professional), fees, and details in accordance with 675 IAC 12-6-
7(g)(19) and (20), GAR.
Indiana Department of Homeland Security
DIVISION OF FIRE & BUILDING SAFETY
PLAN REVIEW DIVISION
402 W. Washington St., Room E245
Indianapolis, IN 46204
Fax & e-mail:
SUPPORT HOOSIER SAFETY
Available At Your Local Licence Branch
In accordance with Section 19 of the General Administrative Rules (675 IAC 12-6-19) a complete set of plans and specifications that conform
exactly to the design that was released by the office of the state building commissioner shall be maintained on the construction jobsite as well as a
copy of the design release.
9015212760, vbuchholz@lrk.com
ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm.
This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans.
Use Internet Browser to View this report, other browsers are not compatible to view this report
Page 2/2
14B1100HC
14B12092
14M0306
9E11026A
AREL
The current code for handicapped accessibility in use in the State of Indiana is Chapter 11 of the
Indiana Building Code (675 IAC 13-2.6) and ICC standard A117.1, 2009 edition (675 IAC 13-2.6).
A 20-inch by 40-inch attic access opening shall be provided in accordance with Section 1209.2, IBC
(675 IAC 13-2.6).
Access and service space for equipment and appliances shall be in accordance with Section 306,
IMC (675 IAC 18-1.6).
Access and working space shall be provided and maintained about all electric equipment in
accordance with Section 110.26, IEC (675 IAC 17-1.8).
NOTE: Canopy (Pool Deck Structure) shall comply with Section 3105.3, IBC; wood of Type IV size.
NOTE: Exterior landings as required by Section 1008.1.6, IBC, for exit discharge doorways in
buildings required to have two or more exits shall be illuminated at all times the building space
served by the means of egress is occupied and shall in the event of power supply failure have an
emergency electrical system that shall automatically illuminate the exterior landings in accordance
with Sections 1006.1 & 1006.3, IBC.
Pursuant to 675 IAC 12-6-21, the issuance of a design release does not relieve the owner from
required compliance with all applicable rules of the commission, even if noncompliant conditions
appear in the plans and specifications that have been filed with the division. The owner is
responsible for correcting any and all areas of noncompliance even if they are discovered
subsequent to the issuing of this design release.
This order is effective upon service. If you would like to request informal review of this order, please complete the informal review form located at
https://www.in.gov/dhs/4149.htm. Following receipt of this form, the Department may modify or reverse the order, however, a request for an informal
review does not extend the deadline for filing a petition for review with the Fire Prevention and Building Safety Commission (Commission).
Additionally, if you have any questions regarding this order, you may contact that Department at (317) 232-2222.
If you desire a formal administrative review of this order by the Commission, you must comply with the requirements of Indiana Code § 4-21.5-3-7
and file a written petition for review within 15 days of the date this order was served, however, this period is extended to 18 days if service is made by
mail. Your petition for review must state facts demonstrating that you are: (1) a person to whom the order is specifically directed; (2) aggrieved or
adversely affected by the order; or (3) entitled to review under any law. You may submit your petition by the following methods:
U.S. MAIL OR PERSONAL SERVICE ONLINE
Fire Prevention and Building Safety Commission By completing the form at
c/o Legal Counsel https://www.in.gov/dhs/4148.htm
302 W. Washington Street, Rm. E208
Indianapolis, IN 46204
For additional information about the administrative review process and applicable templates that may be used for filings, visit the following link
https://www.in.gov/dhs/appeals.htm.
Code review official
Address (name,title of local official,street,city,state and ZIP code
LARRY DAVIS
JIM BLANCHARD
ONE CIVIC SQUARE
CARMEL,IN 46032
DEPT OF COMMUNITY SERVICE
Fax & e-mail: 3175712499, jblanchard@carmel.in.gov
Indiana State Building Commissioner ldavis2@dhs.in.gov