Loading...
HomeMy WebLinkAboutE602a - ELECTRICAL SCHEDULES50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Issued / RevisedDate # Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site. KBSO Project Number: 20070 1344 South Rangeline Road Suite 202 Carmel, IN 46032 317.344.8044 9/3/2021 6:12:28 PM C:\Users\jbogenschutz\Documents\20070 The Corner MEP v19_jbogenschutz.rvt LRK Project Number: 01.18066.00 E602a ELECTRICAL SCHEDULES The Corner Carmel, IN Checker Author 116th Street & Rangeline Carmel, INThe Corner Carmel, IN •01.18066.00DEMAND FACTORS AND DIVERSITIES CALCULATED ACCORDING TO NEC 220.82 Notes: Total Est. Demand: 104 A Total Conn.: 177 A Total Est. Demand: 21633 VA HVAC - DWELLING UNIT -... 5824 VA 0.01% 1 VA Total Conn. Load: 36836 VA HVAC 5200 VA 100.00% 5200 VA Load Classification Connected Load Demand Factor Estimated... Panel Totals Total Amps: 189 A 162 A Total Load: 20040 VA 16796 VA 23 BALCONY LIGHTING 20 A 1 184... 24 21 WASHER 20 A 1 1500... 900... 1 20 A KITCHEN-RECEPT 22 19 4000... 180... 1 20 A KITCHEN-RECEPT 20 17 RANGE 50 A 2 4000... 1500... 1 20 A MICROWAVE 18 15 2600... 2912... 16 13 FCU-1 30 A 2 2600... 2912... 2 35 A CU-1 14 11 1500... 2250... 12 9 DRYER 30 A 2 1500... 2250... 2 30 A EWH-1 10 7 BEDROOM-RECEPT 20 A 1 900... 1260... 1 20 A LIVING ROOM/HALLWAY-RECEPT 8 5 DISHWASHER 20 A 1 1500... 180... 1 20 A KITCHEN-RECEPT 6 3 BATHROOM LIGHTING 20 A 1 210... 800... 1 20 A DISPOSAL 4 1 LIGHTING 20 A 1 198... 1000... 1 20 A REFRIGERATOR 2 CKT Circuit Description Trip Poles A B Poles Trip Circuit Description CKT Enclosure: NEMA 1 MCB Rating: 200 A Mounting: RECESSED Wires: 3 Mains Rating: 125 A Supply From: METER Phases: 1 Mains Type: MCB Location: MULTIPLE Volts: 120/208 Single A.I.C. Rating: 22 KA Branch Panel:S1 DEMAND FACTORS AND DIVERSITIES CALCULATED ACCORDING TO NEC 220.82 Notes: Total Est. Demand: 102 A Total Conn.: 172 A Total Est. Demand: 21133 VA HVAC - DWELLING UNIT -... 5824 VA 0.01% 1 VA Total Conn. Load: 35856 VA HVAC 5200 VA 100.00% 5200 VA Load Classification Connected Load Demand Factor Estimated... Panel Totals Total Amps: 173 A 172 A Total Load: 18004 VA 17852 VA 23 DISPOSAL 20 A 1 180... 24 21 BALCONY LIGHTING 20 A 1 184... 1500... 1 20 A MICROWAVE 22 19 4000... 180... 1 20 A KITCHEN-RECEPT 20 17 RANGE 50 A 2 4000... 180... 1 20 A DATA 18 15 2600... 2912... 16 13 FCU-1 30 A 2 2600... 2912... 2 35 A CU-1 14 11 1500... 2250... 12 9 DRYER 30 A 2 1500... 2250... 2 30 A EWH-1 10 7 BEDROOM-RECEPT 20 A 1 900... 1440... 1 20 A LIVING ROOM/HALLWAY-RECEPT 8 5 DISHWASHER 20 A 1 1500... 180... 1 20 A KITCHEN-RECEPT 6 3 DATA 20 A 1 180... 210... 1 20 A BATHROOM LIGHTING 4 1 LIGHTING 20 A 1 198... 1000... 1 20 A REFRIGERATOR 2 CKT Circuit Description Trip Poles A B Poles Trip Circuit Description CKT Enclosure: NEMA 1 MCB Rating: 200 A Mounting: RECESSED Wires: 3 Mains Rating: 125 A Supply From: METER Phases: 1 Mains Type: MCB Location: MULTIPLE Volts: 120/208 Single A.I.C. Rating: 22 KA Branch Panel:S2 DEMAND FACTORS AND DIVERSITIES CALCULATED ACCORDING TO NEC 220.82 Notes: Total Est. Demand: 114 A Total Conn.: 170 A Total Est. Demand: 23616 VA HVAC - DWELLING UNIT -... 2496 VA 0.01% 0 VA Total Conn. Load: 35304 VA HVAC 7488 VA 100.00% 7488 VA Load Classification Connected Load Demand Factor Estimated... Panel Totals Total Amps: 180 A 156 A Total Load: 19066 VA 16238 VA 23 24 21 LIGHTING 20 A 1 184... 1248... 22 19 3744... 1248... 2 20 A CU-2 20 17 FCU-2 40 A 2 3744... 2250... 18 15 4000... 2250... 2 30 A EWH-1 16 13 RANGE 50 A 2 4000... 1500... 1 20 A MICROWAVE 14 11 KITCHEN-RECEPT 20 A 1 540... 1000... 1 20 A REFRIGERATOR 12 9 DISHWASHER 20 A 1 1500... 800... 1 20 A DISPOSAL 10 7 WASHER 20 A 1 1500... 1500... 8 5 DATA 20 A 1 180... 1500... 2 30 A DRYER 6 3 BATHROOM LIGHTING 20 A 1 210... 246... 1 20 A LIGHTING 4 1 BEDROOM-RECEPT 20 A 1 900... 1260... 1 20 A LIVING ROOM/HALLWAY-RECEPT 2 CKT Circuit Description Trip Poles A B Poles Trip Circuit Description CKT Enclosure: NEMA 1 MCB Rating: 200 A Mounting: RECESSED Wires: 3 Mains Rating: 125 A Supply From: METER Phases: 1 Mains Type: MCB Location: MULTIPLE Volts: 120/208 Single A.I.C. Rating: 22 KA Branch Panel:A1 DEMAND FACTORS AND DIVERSITIES CALCULATED ACCORDING TO NEC 220.82 Notes: Total Est. Demand: 115 A Total Conn.: 172 A Total Est. Demand: 23837 VA HVAC - DWELLING UNIT -... 2496 VA 0.01% 0 VA Total Conn. Load: 35856 VA HVAC 7488 VA 100.00% 7488 VA Load Classification Connected Load Demand Factor Estimated... Panel Totals Total Amps: 184 A 157 A Total Load: 19564 VA 16292 VA 23 24 21 MICROWAVE 20 A 1 1500... 184... 1 20 A BALCONY LIGHTING 22 19 4000... 900... 1 20 A LIVING ROOM/HALLWAY-RECEPT 20 17 RANGE 50 A 2 4000... 900... 1 20 A BEDROOM-RECEPT 18 15 2250... 3744... 16 13 EWH-1 20 A 2 2250... 3744... 2 40 A FCU-2 14 11 1248... 1500... 12 9 CU-2 20 A 2 1248... 1500... 2 30 A DRYER 10 7 REFRIGERATOR 20 A 1 1000... 540... 1 20 A KITCHEN-RECEPT 8 5 DISPOSAL 20 A 1 800... 1500... 1 20 A WASHER 6 3 BATHROOM LIGHTING 20 A 1 210... 900... 1 20 A KITCHEN-RECEPT 4 1 DATA 20 A 1 180... 258... 1 20 A LIGHTING 2 CKT Circuit Description Trip Poles A B Poles Trip Circuit Description CKT Enclosure: NEMA 1 MCB Rating: 200 A Mounting: RECESSED Wires: 3 Mains Rating: 125 A Supply From: METER Phases: 1 Mains Type: MCB Location: MULTIPLE Volts: 120/208 Single A.I.C. Rating: 22 KA Branch Panel:A2 DEMAND FACTORS AND DIVERSITIES CALCULATED ACCORDING TO NEC 220.82 Notes: Total Est. Demand: 128 A Total Conn.: 201 A Total Est. Demand: 26560 VA HVAC - DWELLING UNIT -... 3744 VA 0.01% 0 VA Total Conn. Load: 41858 VA HVAC 7696 VA 100.00% 7696 VA Load Classification Connected Load Demand Factor Estimated... Panel Totals Total Amps: 207 A 194 A Total Load: 21681 VA 20177 VA 23 4000... 900... 1 20 A BEDROOM-RECEPT 24 21 RANGE 50 A 2 4000... 22 19 2250... 3848... 20 17 EWH-2 30 A 2 2250... 3848... 2 40 A FCU-3 18 15 1872... 2000... 16 13 CU-3 25 A 2 1872... 2000... 2 20 A DRYER 14 11 REFRIGERATOR 20 A 1 1000... 720... 1 20 A KITCHEN-RECEPT 12 9 BEDROOM-RECEPT 20 A 1 900... 1500... 1 20 A DISHWASHER 10 7 MICROWAVE 20 A 1 1500... 800... 1 20 A DISPOSAL 8 5 KITCHEN-RECEPT 20 A 1 900... 4000... 1 20 A WASHER 6 3 BATHROOM LIGHTING 20 A 1 210... 357... 1 20 A LIGHTING 4 1 DATA 20 A 1 180... 231... 1 20 A BATHROOM LIGHTING 2 CKT Circuit Description Trip Poles A B Poles Trip Circuit Description CKT Enclosure: NEMA 1 MCB Rating: 200 A Mounting: RECESSED Wires: 3 Mains Rating: 125 A Supply From: METER Phases: 1 Mains Type: MCB Location: MULTIPLE Volts: 120/208 Single A.I.C. Rating: 22 KA Branch Panel:B1 DEMAND FACTORS AND DIVERSITIES CALCULATED ACCORDING TO NEC 220.82 Notes: Total Est. Demand: 120 A Total Conn.: 191 A Total Est. Demand: 25025 VA HVAC - DWELLING UNIT -... 3744 VA 0.01% 0 VA Total Conn. Load: 39761 VA HVAC 7696 VA 100.00% 7696 VA Load Classification Connected Load Demand Factor Estimated... Panel Totals Total Amps: 198 A 182 A Total Load: 20880 VA 18881 VA 23 REFRIGERATOR 20 A 1 1500... 1872... 24 21 1500... 1872... 2 25 A CU-3 22 19 DRYER 20 A 2 1500... 720... 1 20 A KITCHEN-RECEPT 20 17 2250... 3848... 18 15 EWH-2 30 A 2 2250... 3848... 2 20 A FCU-3 16 13 4000... 1500... 1 20 A DISHWASHER 14 11 RANGE 50 A 2 4000... 800... 1 20 A DISPOSAL 12 9 KITCHEN-RECEPT 20 A 1 540... 1500... 1 20 A MICROWAVE 10 7 LIGHTING 20 A 1 381... 210... 1 20 A BATHROOM LIGHTING 8 5 BEDROOM-RECEPT 20 A 1 1260... 1500... 1 20 A WASHER 6 3 LIVING ROOM/HALLWAY-RECEPT 20 A 1 1080... 720... 1 20 A OFFICE-RECEPT 4 1 BATHROOM LIGHTING 20 A 1 210... 900... 1 20 A BEDROOM-RECEPT 2 CKT Circuit Description Trip Poles A B Poles Trip Circuit Description CKT Enclosure: NEMA 1 MCB Rating: 200 A Mounting: RECESSED Wires: 3 Mains Rating: 125 A Supply From: METER Phases: 1 Mains Type: MCB Location: MULTIPLE Volts: 120/208 Single A.I.C. Rating: 22 KA Branch Panel:B4 DEMAND FACTORS AND DIVERSITIES CALCULATED ACCORDING TO NEC 220.82 Notes: Total Est. Demand: 119 A Total Conn.: 189 A Total Est. Demand: 24855 VA HVAC - DWELLING UNIT -... 3744 VA 0.01% 0 VA Total Conn. Load: 39337 VA HVAC 7696 VA 100.00% 7696 VA Load Classification Connected Load Demand Factor Estimated... Panel Totals Total Amps: 199 A 175 A Total Load: 21100 VA 18237 VA 23 KITCHEN-RECEPT 20 A 1 720... 4000... 24 21 WASHER 20 A 1 4000... 4000... 2 50 A RANGE 22 19 1500... 800... 1 20 A DISPOSAL 20 17 DRYER 30 A 2 1500... 1872... 18 15 DATA 20 A 1 180... 1872... 2 25 A CU-3 16 13 LIVING ROOM/HALLWAY-RECEPT 20 A 1 1080... 900... 1 20 A BEDROOM-RECEPT 14 11 2250... 3848... 12 9 EWH-2 30 A 2 2250... 3848... 2 40 A FCU-3 10 7 MICROWAVE 20 A 1 1500... 357... 1 20 A LIGHTING 8 5 KITCHEN-RECEPT 20 A 1 360... 180... 1 20 A DISHWASHER 6 3 FRACTIONAL HP MOTOR 20 A 1 210... 1000... 1 20 A REFRIGERATOR 4 1 BEDROOM-RECEPT 20 A 1 900... 210... 1 20 A BATHROOM LIGHTING 2 CKT Circuit Description Trip Poles A B Poles Trip Circuit Description CKT Enclosure: NEMA 1 MCB Rating: 200 A Mounting: RECESSED Wires: 3 Mains Rating: 125 A Supply From: METER Phases: 1 Mains Type: MCB Location: MULTIPLE Volts: 120/208 Single A.I.C. Rating: 22 KA Branch Panel:B2 DEMAND FACTORS AND DIVERSITIES CALCULATED ACCORDING TO NEC 220.82 Notes: Total Est. Demand: 118 A Total Conn.: 186 A Total Est. Demand: 24599 VA HVAC - DWELLING UNIT -... 3744 VA 0.01% 0 VA Total Conn. Load: 38697 VA HVAC 7696 VA 100.00% 7696 VA Load Classification Connected Load Demand Factor Estimated... Panel Totals Total Amps: 187 A 185 A Total Load: 19435 VA 19262 VA 23 BEDROOM-RECEPT 20 A 1 1080... 24 21 MICROWAVE 20 A 1 1500... 1000... 1 20 A REFRIGERATOR 22 19 DISPOSAL 20 A 1 800... 222... 1 20 A BATHROOM LIGHTING 20 17 DISHWASHER 20 A 1 1500... 1080... 1 20 A BEDROOM-RECEPT 18 15 2250... 3848... 16 13 EWH-2 30 A 2 2250... 3848... 2 20 A FCU-3 14 11 1500... 1872... 12 9 DRYER 30 A 2 1500... 1872... 2 25 A CU-3 10 7 4000... 1260... 1 20 A LIVING ROOM/HALLWAY-RECEPT 8 5 RANGE 50 A 2 4000... 180... 1 20 A DATA 6 3 BATHROOM LIGHTING 20 A 1 210... 720... 1 20 A KITCHEN-RECEPT 4 1 BEDROOM-RECEPT 20 A 1 345... 360... 1 20 A BEDROOM-RECEPT 2 CKT Circuit Description Trip Poles A B Poles Trip Circuit Description CKT Enclosure: NEMA 1 MCB Rating: 200 A Mounting: RECESSED Wires: 3 Mains Rating: 125 A Supply From: METER Phases: 1 Mains Type: MCB Location: MULTIPLE Volts: 120/208 Single A.I.C. Rating: 22 KA Branch Panel:B3 DEMAND FACTORS AND DIVERSITIES CALCULATED ACCORDING TO NEC 220.82 Notes: Total Est. Demand: 114 A Total Conn.: 172 A Total Est. Demand: 23775 VA HVAC - DWELLING UNIT -... 2496 VA 0.01% 0 VA Total Conn. Load: 35700 VA HVAC 7488 VA 100.00% 7488 VA Load Classification Connected Load Demand Factor Estimated... Panel Totals Total Amps: 171 A 172 A Total Load: 17752 VA 17948 VA 23 24 21 BATHROOM LIGHTING 20 A 1 210... 22 19 KITCHEN-RECEPT 20 A 1 540... 1000... 1 20 A REFRIGERATOR 20 17 DISHWASHER 20 A 1 1500... 1500... 1 20 A WASHER 18 15 3744... 4000... 16 13 FCU-2 40 A 2 3744... 4000... 2 50 A RANGE 14 11 1500... 2250... 12 9 DRYER 30 A 2 1500... 2250... 2 30 A EWH-1 10 7 BEDROOM-RECEPT 20 A 1 900... 1248... 8 5 KITCHEN-RECEPT 20 A 1 180... 1248... 2 20 A CU-2 6 3 LIGHTING 20 A 1 466... 800... 1 20 A DISPOSAL 4 1 DATA 20 A 1 180... 1440... 1 20 A LIVING ROOM/HALLWAY-RECEPT 2 CKT Circuit Description Trip Poles A B Poles Trip Circuit Description CKT Enclosure: NEMA 1 MCB Rating: 200 A Mounting: RECESSED Wires: 3 Mains Rating: 125 A Supply From: METER Phases: 1 Mains Type: MCB Location: MULTIPLE Volts: 120/208 Single A.I.C. Rating: 22 KA Branch Panel:A3 1 06.16.21 Permit Set 2 08.20.21 IFC Set 3 09.01.21 IFC Set 11/15/21