Loading...
HomeMy WebLinkAboutE603a - ELECTRICAL SCHEDULES50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Issued / RevisedDate # Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site. KBSO Project Number: 20070 1344 South Rangeline Road Suite 202 Carmel, IN 46032 317.344.8044 9/3/2021 6:12:34 PM C:\Users\jbogenschutz\Documents\20070 The Corner MEP v19_jbogenschutz.rvt LRK Project Number: 01.18066.00 E603a ELECTRICAL SCHEDULES The Corner Carmel, IN Checker Author 116th Street & Rangeline Carmel, INThe Corner Carmel, IN •01.18066.00DEMAND FACTORS AND DIVERSITIES CALCULATED ACCORDING TO NEC 220.82 Notes: Total Est. Demand: 115 A Total Conn.: 172 A Total Est. Demand: 23835 VA HVAC - DWELLING UNIT -... 2496 VA 0.01% 0 VA Total Conn. Load: 35852 VA HVAC 7488 VA 100.00% 7488 VA Load Classification Connected Load Demand Factor Estimated... Panel Totals Total Amps: 168 A 176 A Total Load: 17460 VA 18392 VA 23 1248... 24 21 2250... 1248... 2 20 A CU-2 22 19 EWH-1 30 A 2 2250... 1500... 20 17 WASHER 20 A 1 1500... 1500... 2 30 A DRYER 18 15 DISHWASHER 20 A 1 1500... 1000... 1 20 A REFRIGERATOR 16 13 DISPOSAL 20 A 1 800... 4000... 14 11 MICROWAVE 20 A 1 1500... 4000... 2 50 A RANGE 12 9 KITCHEN-RECEPT 20 A 1 540... 540... 1 20 A KITCHEN-RECEPT 10 7 1440... 1 20 A LIVING ROOM/HALLWAY-RECEPT 8 5 DATA 20 A 1 180... 3744... 6 3 BATHROOM LIGHTING 20 A 1 210... 3744... 2 40 A FCU-2 4 1 DWELLING UNIT 20 A 1 258... 900... 1 20 A BEDROOM-RECEPT 2 CKT Circuit Description Trip Poles A B Poles Trip Circuit Description CKT Enclosure: NEMA 1 MCB Rating: 200 A Mounting: RECESSED Wires: 3 Mains Rating: 200 A Supply From: METER Phases: 1 Mains Type: MCB Location: MULTIPLE Volts: 120/208 Single A.I.C. Rating: 22kA Branch Panel:A4 DEMAND FACTORS AND DIVERSITIES CALCULATED ACCORDING TO NEC 220.82 Notes: Total Est. Demand: 122 A Total Conn.: 186 A Total Est. Demand: 25281 VA HVAC - DWELLING UNIT -... 3744 VA 0.01% 0 VA Total Conn. Load: 38661 VA HVAC 7696 VA 100.00% 7696 VA Load Classification Connected Load Demand Factor Estimated... Panel Totals Total Amps: 191 A 179 A Total Load: 20060 VA 18601 VA 23 BATHROOM LIGHTING 20 A 1 210... 360... 1 20 A RECEPT - KITCHEN 24 21 1500... 1 20 A MICROWAVE 22 19 3848... 4000... 20 17 FCU-3 40 A 2 3848... 4000... 2 50 A RANGE 18 15 1872... 2250... 16 13 CU-3 25 A 2 1872... 2250... 2 30 A EWH-2 14 11 LIVING ROOM/HALLWAY-RECEPT 20 A 1 1260... 1500... 12 9 KITCHEN-RECEPT 20 A 1 900... 1500... 2 30 A DRYER 10 7 REFRIGERATOR 20 A 1 1000... 1080... 1 20 A BEDROOM-RECEPT 8 5 WASHER 20 A 1 1500... 210... 1 20 A BATHROOM LIGHTING 6 3 LIGHTING 20 A 1 321... 900... 1 20 A BEDROOM-RECEPT 4 1 DATA 20 A 1 180... 800... 1 20 A DISPOSAL 2 CKT Circuit Description Trip Poles A B Poles Trip Circuit Description CKT Enclosure: NEMA 1 MCB Rating: 200 A Mounting: RECESSED Wires: 3 Mains Rating: 200 A Supply From: METER Phases: 1 Mains Type: MCB Location: MULTIPLE Volts: 120/208 Single A.I.C. Rating: 22Ka Branch Panel:B5 1 08.20.21 IFC Set 2 09.01.21 IFC Set DEMAND FACTORS AND DIVERSITIES CALCULATED ACCORDING TO NEC 220.82 Notes: Total Est. Demand: 115 A Total Conn.: 172 A Total Est. Demand: 23831 VA HVAC - DWELLING UNIT -... 2496 VA 0.01% 0 VA Total Conn. Load: 35840 VA HVAC 7488 VA 100.00% 7488 VA Load Classification Connected Load Demand Factor Estimated... Panel Totals Total Amps: 186 A 153 A Total Load: 19928 VA 15912 VA 23 24 21 4000... 540... 1 20 A KITCHEN-RECEPT 22 19 RANGE 50 A 2 4000... 900... 1 20 A KITCHEN-RECEPT 20 17 REFRIGERATOR 20 A 1 1000... 1500... 1 20 A MICROWAVE 18 15 2250... 3744... 16 13 EWH-1 30 A 2 2250... 3744... 2 40 A FCU-2 14 11 1248... 800... 1 20 A DISPOSAL 12 9 CU-2 20 A 2 1248... 1500... 1 20 A DISHWASHER 10 7 1500... 1080... 1 20 A LIVING ROOM-RECPT 8 5 DRYER 30 A 2 1500... 1500... 1 20 A WASHER 6 3 RESTROOM-RECPT & LGTG 20 A 1 210... 180... 1 20 A DEMARC 4 1 BEDROOM-RECEPT 20 A 1 900... 246... 1 20 A LIGHTING 2 CKT Circuit Description Trip Poles A B Poles Trip Circuit Description CKT Enclosure: NEMA 1 MCB Rating: 200 A Mounting: RECESSED Wires: 3 Mains Rating: 125 A Supply From: METER Phases: 1 Mains Type: MCB Location: MULTIPLE Volts: 120/208 Single A.I.C. Rating: 22 KA Branch Panel:A5 DEMAND FACTORS AND DIVERSITIES CALCULATED ACCORDING TO NEC 220.82 Notes: Total Est. Demand: 85 A Total Conn.: 132 A Total Est. Demand: 17777 VA Total Conn. Load: 27465 VA HVAC - DWELLING UNIT -... 5824 VA 0.01% 1 VA Load Classification Connected Load Demand Factor Estimated... Panel Totals Total Amps: 134 A 130 A Total Load: 13982 VA 13483 VA 23 24 21 2912... 22 19 LIGHTING 20 A 1 111... 2912... 2 35 A CU-1 20 17 RECEPT-KITCHEN 20 A 1 180... 900... 1 20 A RECEPT-LIVING ROOM 18 15 1750... 180... 1 20 A RECEPT-KITCHEN 16 13 RANGE 50 A 2 1750... 1500... 1 20 A WASHER 14 11 DISPOSAL 20 A 1 180... 1500... 1 20 A DISHWASHER 12 9 DATA 20 A 1 180... 1000... 1 20 A REFRIGERATOR 10 7 WASHER 20 A 1 1500... 2000... 8 5 RESTROOM-RECPT & LIGHTING 20 A 1 210... 2000... 2 30 A DRYER 6 3 750... 2600... 4 1 EWH-1 30 A 2 750... 2600... 2 30 A FCU-1 2 CKT Circuit Description Trip Poles A B Poles Trip Circuit Description CKT Enclosure: NEMA 1 MCB Rating: 200 A Mounting: RECESSED Wires: 3 Mains Rating: 125 A Supply From: METER Phases: 1 Mains Type: MCB Location: MULTIPLE Volts: 120/208 Single A.I.C. Rating: 22kA Branch Panel:S3 11/15/21