EL113b - PARTIAL L03 LIGHTING PLANS - BLDG A
MM M M 56 7 8 9 10 1213 A1 11 14 M.9 B-AB H24 H24 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4H5 H5 H5 H5 H5 H5 H5 H5 H5 H5 H5 H5 H5 X1 X2 X1 X1 HA1B -52 H24 H24 H24 H24 S2 A326 ELEC. A344 MECH. A345 TELECOMM. A346 A1f A339 ELEV.A1 ? STAIR A1 A348 STORAGE A343 B1r A338 CORRIDOR A342 B1k A336 S1 alt2 A336 A1d A337 S1 A335 A1d A333 A1 alt2 A332 A1d A331 B1e A330 B1d alt1 A328 A1d A329 A1c A327 S2 A326 Space B296 Space B297 E HPA3A -14 HPA3A -15 HPA3A -15 HPA3A -14 HPA3A -15 E HPA3A -15 HPA3A -14 E HPA3A -15 HPA3A -14 HPA3A -15 E HPA3A -14 2 / E404 3 / E413 8 / E403 2 / E412 1 / E401 5 / E401 8 / E403 3 / E403 8 / E403 8 / E403 7 / E403 2 / E411 1 / E411 1 / E402 H4 E E 50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Issued / RevisedDate # Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site. KBSO Project Number: 20070 1344 South Rangeline Road Suite 202 Carmel, IN 46032 317.344.8044 9/3/2021 6:14:11 PM C:\Users\jbogenschutz\Documents\20070 The Corner MEP v19_jbogenschutz.rvt LRK Project Number: 01.18066.00 EL113b PARTIAL L03 LIGHTING PLANS -BLDG A The Corner Carmel, IN Checker Author 116th Street & Rangeline Carmel, INThe Corner Carmel, IN •01.18066.001/8" = 1'-0" PARTIAL BLDG A L03 SE LIGHTING PLAN 1 1 06.16.21 Permit Set 2 07.15.21 Addendum A 3 08.20.21 IFC Set 4 09.01.21 IFC Set GENERAL NOTES A WIRE EVERY THIRD HALLWAY FIXTURE, FIXTURES AT EGRESS DOORS AND FIXTURES AT HALLWAY INTERSECTIONS TO BE ALWAYS ON (NO OCCUPANCY SENSOR CONTROL). B GROUP OCCUPANCY SENSORS TO CONTROL UNBROKEN SECTIONS OF HALLWAY. C WALL SCONCES MOUNTED PERPENDICULAR TO FLOOR WITH FIXTURE CENTER AT 6'-0" AFF. D FIXTURES TAGGED WITH 'E' ARE FED FROM LIGHTING INVERTER FOR EMERGENCY EGRESS. E OCCUPANCY SENSOR LOCATIONS SHOWN ARE NOT EXACT. CENTER SENSORS WITHIN HALLWAY AND SPACE AT APPROXIMATELY 30'-0" ON CENTER OR ACCORDING TO MANNUFACTURERS RECOMENDATION. MOUNT TO BOTTOM OF DUCT SUPPORTS. COORDINATE WITH MECHANICAL. F MOUNT EXIT SIGNS AT 7'6". WALL MOUNT WHERE POSSIBLE. PENDENT MOUNT ELSEWHERE. G MOUNT PENDANT FIXTURE IN ELEVATOR LOBBY SO BOTTOM OF FIXTURE IS 7'-8" AFF. 11/15/21