Loading...
HomeMy WebLinkAboutEL114b - PARTIAL L04 LIGHTING PLANS - BLDG AMM M M 56 7 8 9 10 1213 A1 11 14 M.9 H24 H24 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4H5 H5 H5 H5 H5 H5 H5 H5 H5 H5 H5 H5 H5 X1 X2 X1 X1 H24 H24 H24 H24 A1f A439 B1r A438 MECH. A445 TELECOMM. A446 ELEV.A1 A354 STAIR A1 A448 CORRIDOR A442 ELEC. A444 STORAGE A443 B1k A436 A1d A437 S1 A435 A1d A433 S1 alt2 A434 A1alt2 A432 B1e A430 A1d A431 A1d A429 B1d A428 Space A369 Space A370 A1c A427 HA1B -52 HPA5A -20 E E HPA5A -20 HPA5A -13 HPA5A -20 HPA5A -13 HPA5A -20 HPA5A -13 E HPA5A -20 HPA5A -13 HPA5A -20 HPA5A -13 HPA5A -13 HPA5A -20 2 / E404 3 / E413 8 / E403 2 / E412 1 / E401 5 / E401 8 / E403 3 / E403 8 / E403 8 / E403 7 / E403 2 / E411 1 / E411 1 / E402 1 / E409 50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Issued / RevisedDate # Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site. KBSO Project Number: 20070 1344 South Rangeline Road Suite 202 Carmel, IN 46032 317.344.8044 9/3/2021 6:14:44 PM C:\Users\jbogenschutz\Documents\20070 The Corner MEP v19_jbogenschutz.rvt LRK Project Number: 01.18066.00 EL114b PARTIAL L04 LIGHTING PLANS -BLDG A The Corner Carmel, IN Checker Author 116th Street & Rangeline Carmel, INThe Corner Carmel, IN •01.18066.001/8" = 1'-0" PARTIAL BLDG A L04 SE LIGHTING PLAN 1 1 06.16.21 Permit Set 2 07.15.21 Addendum A 3 08.20.21 IFC Set 4 09.01.21 IFC Set GENERAL NOTES A WIRE EVERY THIRD HALLWAY FIXTURE, FIXTURES AT EGRESS DOORS AND FIXTURES AT HALLWAY INTERSECTIONS TO BE ALWAYS ON (NO OCCUPANCY SENSOR CONTROL). B GROUP OCCUPANCY SENSORS TO CONTROL UNBROKEN SECTIONS OF HALLWAY. C WALL SCONCES MOUNTED PERPENDICULAR TO FLOOR WITH FIXTURE CENTER AT 6'-0" AFF. D FIXTURES TAGGED WITH 'E' ARE FED FROM LIGHTING INVERTER FOR EMERGENCY EGRESS. E OCCUPANCY SENSOR LOCATIONS SHOWN ARE NOT EXACT. CENTER SENSORS WITHIN HALLWAY AND SPACE AT APPROXIMATELY 30'-0" ON CENTER OR ACCORDING TO MANNUFACTURERS RECOMENDATION. MOUNT TO BOTTOM OF DUCT SUPPORTS. COORDINATE WITH MECHANICAL. F MOUNT EXIT SIGNS AT 7'6". WALL MOUNT WHERE POSSIBLE. PENDENT MOUNT ELSEWHERE. G MOUNT PENDANT FIXTURE IN ELEVATOR LOBBY SO BOTTOM OF FIXTURE IS 7'-8" AFF. 11/15/21