Loading...
HomeMy WebLinkAboutEL115a - PARTIAL L05 LIGHTING PLANS - BLDG AM M M M M M M M M H24 H24 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4H4 H4 H4 H5 H5 H5 H5 H5 H5 H5 H5 H5 H5 H5 H5 H5 H5 X1 X1 X1 X1 ELEC. P105 A1b A515 A2g A512 A1d A513 CORRIDOR A540 B1e alt1 A510 A1d A511 Space P150 S1 alt3 A508 S1 A509 A1 alt3 A506 A1d A507 A2b A505 B1f alt1 A504 S1 alt.1 A503 B3 alt1 A502 Space P159 Space P160 Space P161 A1e A501 STAIR A2 A550 Space P164 Space P165 HA1A -1 E HPA5B -19 HPA5B -16 E HPA5B -19 E HPA5B -19 HPA5B -16 HPA5B -16 HPA5B -19 HPA5B -16 HPA5B -19HPA5B -16 E HPA5B -19 E HPA5B -19 HPA5B -16 H24HPA5B -166 / E403 4 / E407 8 / E403 3 / E411 8 / E403 1 / E401 6 / E401 8 / E403 4 / E403 4 / E406 4 / E411 4 / E401 1 / E404 1 / E414 K AA AD AG AH 4 A1 A2 A3 AF AC AB M.9 H24 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H5 H5 H5 H5 H5 H5 H5 H5H5 X1 X1 X1 H24 H4 H5 H5 HA1A -2 S2 A526 B4 alt1 A524 STAIR A3 A549 A1d A523 A1d A521 A2n A522 Space P131 A3 alt1 A525 Space P133 A2m 520 B4 alt1 A518 Space P136 S2 A516 A2f alt1 A514S1a A517 Space P141 Space P142 A3 alt1 A525 S2 A526 A3 alt1 A525 H5 H4E HPA5A -19 HPA5A -19 E HPA5B -16 EHPA5B -19 HPA5B -16 HPA5B -19 E HPA5B -16 E HPA5B -19 HPA5A -14 HPA5A -14 1 / E402 2 / E414 1 / E406 1 / E406 1 / E409 8 / E403 2 / E414 1 / E409 2 / E414 8 / E403 1 / E402 2 / E401 3 / E407 50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Issued / RevisedDate # Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site. KBSO Project Number: 20070 1344 South Rangeline Road Suite 202 Carmel, IN 46032 317.344.8044 9/3/2021 6:14:58 PM C:\Users\jbogenschutz\Documents\20070 The Corner MEP v19_jbogenschutz.rvt LRK Project Number: 01.18066.00 EL115a PARTIAL L05 LIGHTING PLANS -BLDG A The Corner Carmel, IN Checker Author 116th Street & Rangeline Carmel, INThe Corner Carmel, IN •01.18066.001/8" = 1'-0" PARTIAL BLDG A L05 NW LIGHTING PLAN 1 1/8" = 1'-0" PARTIAL BLDG A L05 NE LIGHTING PLAN 2 1 06.16.21 Permit Set 2 07.15.21 Addendum A 3 08.20.21 IFC Set 4 09.01.21 IFC Set GENERAL NOTES A WIRE EVERY THIRD HALLWAY FIXTURE, FIXTURES AT EGRESS DOORS AND FIXTURES AT HALLWAY INTERSECTIONS TO BE ALWAYS ON (NO OCCUPANCY SENSOR CONTROL). B GROUP OCCUPANCY SENSORS TO CONTROL UNBROKEN SECTIONS OF HALLWAY. C WALL SCONCES MOUNTED PERPENDICULAR TO FLOOR WITH FIXTURE CENTER AT 6'-0" AFF. D FIXTURES TAGGED WITH 'E' ARE FED FROM LIGHTING INVERTER FOR EMERGENCY EGRESS. E OCCUPANCY SENSOR LOCATIONS SHOWN ARE NOT EXACT. CENTER SENSORS WITHIN HALLWAY AND SPACE AT APPROXIMATELY 30'-0" ON CENTER OR ACCORDING TO MANNUFACTURERS RECOMENDATION. MOUNT TO BOTTOM OF DUCT SUPPORTS. COORDINATE WITH MECHANICAL. F MOUNT EXIT SIGNS AT 7'6". WALL MOUNT WHERE POSSIBLE. PENDENT MOUNT ELSEWHERE. G MOUNT PENDANT FIXTURE IN ELEVATOR LOBBY SO BOTTOM OF FIXTURE IS 7'-8" AFF. 11/15/21