Loading...
HomeMy WebLinkAboutEP111b - PARTIAL L01 ELECTRICAL PLANS - BLDG AJ J J J J J J S J J FFFFJ SF FS SS S SSF F S S S T T J CR ESCR ESESCR CES CRCR CR ES C CESCRCC CC WAP WAP S S S S SS S S S S S S S S S S S S J SS WAP J J SSDC S S S S S ESJ JFAAVITREOUSCHINABATHROOMSINKVOX K-5373 VITREOUSCHINABATHROOM SINKVOX K-5373 CRCR NACT J TS FS TS FS TS FS S FACP S HA1BEP111b 4 Space 3 ELEV A1 141 ELEC. A108 PUMP ROOM A106 1 6 7 EP111b 2 10 10 +60" 11 11 11 11 11 1 2 3 WP WP EP111b 3 +24" +24" +60" 13 22 10 10 +60"+60" RESTROOM G108 RESTROOM G109 CORR. G110 SPORTS SIMULATOR G112 FITNESS G113 LEASING G114 ELEC/TCOM G115 WORK ROOM G116 OFFICE G117 10 EWH-2 14 15 6 6 EF-1 UH-4 16 EP111b 5 56 7 8 9 10 1213 L M N A1 11 14 M.8M.9 B-AB B-A2 B-A1 17 1819 20 USB21 WP EF-1 23 UH-6 UH-6 HA1B -2 HA1B -3 HA1B-4HA1B-5 2 2 2 2 2 HA1B- 6HA1B- 8HA1B-7 HA1B-9 HA1B-10HA1B-10HA1B-11HA1B-11HA1B-11 HA1B-10 HA1B -12 HA1B-13 HA1B -14 HA1B -15 HA1B-16,18 HA1B-17HA1B -19 HA1B-17HA1B-20 HA1B-21 HA1B-21 EF-1 HA1B-22 HA1B -23 HA1B-24HA1B-25HA1B-26HA1B-27HA1B-28HA1B-2924 24 24 24 24 24 HA1B -30 HA1A- 3 7 7 HA1A- 4 UH-1 HA1B-31 HA1B-33 2 2 USB USB USB USB HA1A-12 HA1A-13 28 HA1B-32 WP HA1B- 1 HA1B- 1 3 HA1B 3 GEB 4 5 ACCESS LADDER TO MECHANICAL PLATFORM ABOVE WORK ROOM 10 HA1B-34 HA1B-35 HA1B-36HA1B-37HA1B-38HA1B-39 PUMP ROOM A106 8 UH-2 HA1A-9,11 FIRE PUMP CNTRL PANEL JOCKEY PUMP CNTRL PANEL 25 26 27 2 HA1AMDPA LCP 12 GEB 8 L HA1A- 5 HA1A- 7 UH-2 HA1A-6,8 8 8 L LOCATED ABOVE WORKROOM FCU-7 FCU-6 FCU-6 9 9 9 HA1B-40 HA1B-43,45 HA1B-42,44 HA1B-46,48 50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Issued / RevisedDate # Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site. KBSO Project Number: 20070 1344 South Rangeline Road Suite 202 Carmel, IN 46032 317.344.8044 9/3/2021 6:19:21 PM C:\Users\jbogenschutz\Documents\20070 The Corner MEP v19_jbogenschutz.rvt LRK Project Number: 01.18066.00 EP111b PARTIAL L01 ELECTRICAL PLANS -BLDG A The Corner Carmel, IN Checker Author 116th Street & Rangeline Carmel, INThe Corner Carmel, IN •01.18066.001/8" = 1'-0" PARTIAL BLDG A L01 SE ELECTRICAL PLAN 1 1/4" = 1'-0" ENLARGED AMENITY ELEC/TCOM ROOM4 GENERAL NOTES A REFER TO SHEET E-000 FOR GENERAL ELECTRICAL NOTES, SYMBOLS AND ABBREVIATIONS. B REFER TO E-600 SERIES SHEETS FOR LOAD CENTER CIRCUIT SCHEDULES FOR EACH DWELLNG UNIT TYPE. C ALL RECEPTACLES SHOWN LOCATED ON BUILDING EXTERIOR OR ROOF SHOULD BE PROVIDED WITH IN-USE WEATHERPROOF ENCLOSURE. D ROOF TOP CONDENSING UNITS SERVING RESIDENT UNITS FED FROM ASSOCIATED APARTMENT LOAD CENTER. SEE ENLARGED UNIT PLANS IN E-400 SERIES DRAWINGS FOR CIRCUIT INFORMATION. E CONDUCTOR SIZES LISTED ARE ACCURATE FOR CIRCUITS UP TO 100' IN LENGTH. FOR CIRCUIT LENGTHS GREATHER THAN 100', UPSIZE CONDUCTORS AS NECESSARY TO LIMIT VOLTAGE DROP TO 3% OR LESS FROM PANEL. F CONTRACTOR TO PROVIDE (2) 3/4" MICRODUCTS AND (1) 3/8" SMOOTHBORE INNER DUCT WITH PULL STRINGS AND BUSHINGS FROM IDF TERMINAL BOARD TO EACH APARTMENT UNIT HOME NETWORK ENCLOSURE. G ALL TV LOCATIONS SHOWN TO RECEIVE (2) RJ45 JACKS WITH CAT 6 CABLING ROUTED FROM NEAREST IDF CLOSET UNLESS NOTED OTHERWISE. H PROVIDE FIRE STOP FOR ALL COMMUNICATION RACEWAYS THAT PENETRATE FIRE WALLS. I ALL COMMUNICATION CABLE TO BE INSTALLED AND TESTED ACCORDING TO BICSI STANDARDS. REPLACE ANY CABLING THAT DOES NOT PASS TESTING PRIOR TO FINAL TERMINATIONS. J ALL FIRE STROBES TO BE 75cd UNLESS NOTED OTHERWISE. K PROVIDE FLOW AND TAMPER SWITCHES FOR ALL FIRE RISERS AND STAND PIPES. COORDINATE LOCATIONS WITH FIRE SUPRESSION SYSTEM DESIGNER. SHEET KEYNOTES 1 PROVIDE UNDERGROUND CONDUIT ACCORDING TO ONE-LINE DIAGRAM. COORDINATE FINAL ROUTING WITH SERVICE CONDUITS SHOWN ON SITE PLAN SHEET ES101. 2 PROVIDE FIRE ALARM CONTROL PANEL WITH HARDWIRED AND CELLULAR DIALER. PROVIDE 120V, 20A DEDICATE POWER CIRCUIT. PROVIDE EITHER POTS OR IP CONNECTION AS DETERMINED BY OWNER FOR PRIMARY COMMUNICATION. 3 PROVIDE DEDICATED 120V, 20A CIRCUIT FOR FIRE ALARM NAC PANEL 4 PROVIDE 4'x8'x3/4" FIRE RATED PLYWOOD BACKING ON TWO WALLS. 5 PROVIDE GROUNDING ELECTRODE BUS FOR TELECOM EQUIPMENT 6 PROVIDE 120V HARD WIRED CONNECTION RESTROOM EXHAUST FAN. WIRE TO LIGHTING CIRCUIT. ENSURE LIGHTING CONTROL DEVICE IS RATED FOR FAN OPERATION. 7 PROVIDE 120V, 20A DEDICATED CIRCUIT FOR ELECTRIC UNIT HEATER. 8 PROVIDE 208V, 20A DEDICATED CIRCUIT FOR ELECTRIC UNIT HEATER. 9 PROVIDE NON-FUSED DISCONNECT AND 208V, 1PH, 50A CIRCUIT FOR FAN COIL UNIT. USE (2) #8 AND (1) #10 GND. 10 PROVIDE 120V CONNECTION TO SECURE DOOR POWER SUPPLY. 11 INSTALL GFCI RECEPTACLE WITH IN-USE WEATHERPROOF ENCLOSURE. WIRE RECEPTACLE TO JUNCTION BOX LOCATED ON INSIDE WALL NEAR PODIUM STRUCTURE. LEAVE 12" OF WIRE COILED INSIDE J-BOX FOR FUTURE CONNECTION TO RETAIL TENANT PANEL. 12 PROVIDE LIGHTING CONTROL PANEL FOR SITE LIGHTING. 13 UNDER COUNTER RECEPTACLE FOR DISHWASHER. 14 TV RECEPTACLE MOUNTED ABOVE SINK 15 PROVIDE EQUIPMENT DISCONNECT AND 208V, 1PH CIRCUIT FOR ELECTRIC WATER HEATER. USE (2) #10AWG AND #10 GND. 16 PROVIDE ROUGH IN AND 120V, 20A POWER CIRCUIT FOR SPORTS SIMULATOR. COORDINATE WITH VENDOR FOR FINAL POWER REQUIREMENTS. 17 PROVIDE ROUGH-IN FOR GUEST ENTRY. 18 PROVIDE ROUGH IN FOR VOLUME CONTROL 46" AFF. COORDINATE WITH VOLUME CONTROL INSTALLER FOR EXACT LOCATION. 19 PROVIDE ROUGH IN FOR TOUCH SCREEN KIOSK. COORDINATE WITH KIOSK INSTALLER FOR EXACT LOCATION. TOP OF SCREEN MUST NOT EXCEED 48" AFF. 20 DATA HOME-RUN TO SPORTS SIMULATOR PC LOCATION. 21 CEILING MOUNTED DUPLEX RECEPTACLE AND 2x DATA FOR PROJECTOR. COORDINATE WITH PROJECTOR INSTALLER FOR EXACT LOCATION. 22 UNDER COUNTER RECEPTACLE TIED TO TOGGLE WALL SWITCH FOR DISPOSAL 23 PROVIDE 120V HARD WIRED CONNECTION TO GAS FIREPLACE IGNITION. COORDINATE EXACT LOCATION WITH FIREPLACE INSTALLER PRIOR TO ROUGH-IN 24 PROVIDE FLOOR BOX WITH DEDICATED DUPLEX RECEPTACLE, (1) COAX AND (2) CAT6 DROPS. 25 PROVIDE ELECTRIC FEED TO FIRE PUMP CONTROL PANEL ACCORDING TO ONE-LINE DIAGRAM ON SHEET E903. PROVIDE FINAL CONNECTION FROM CONTROL PANEL TO PUMP MOTOR. 26 PROVIDE ELECTRIC FEED TO FIRE JOCKEY PUMP CONTROL PANEL ACCORDING TO ONE-LINE DIAGRAM ON SHEET E903. PROVIDE FINAL CONNECTION FROM CONTROL PANEL TO PUMP MOTOR. 27 PROVIDE ELECTRIC FEED TO PACKAGED DOMESTIC BOOSTER SYSTEM ACCORDING TO ONE-LINE DIAGRAM ON SHEET E903. 28 UNDER COUNTER RECEPTACLE FOR ICE MAKER 1/4" = 1'-0" ENLARGED WATER ROOM2 1/4" = 1'-0" ENLARGED ELECTRICAL ROOM 3 1/4" = 1'-0" MECHANICAL PLATFORM5 1 06.16.21 Permit Set 2 08.20.21 IFC Set 3 09.01.21 IFC Set 11/15/21