Loading...
HomeMy WebLinkAboutEP112a - PARTIAL L02 ELECTRICAL PLANS - BLDG ATF F SS SS S TFFSSS S 3 FCU-5HPA3B-1,3HPA3B- 2 HPA3B- 2 HPA3B- 2 HPA3B- 2 HPA3B- 2HPA3B- 2HPA3B- 7B C D E F G A1 3 2 1 A 1.21.1 F.9 STAIR A2 A250 Room 13 A2f A214 S1a A217 A1b A215 CORRIDOR A240 A2g A212 A1d A213 B1e alt 1 A210 A1d A211 S1 A209 S1 alt 3 A208 A1 alt 3 A206 A1d A207 A2b A205 B1f A204 B3 A202 A1e A201 S1 alt 1 A203 ELEC. P102 Space B264 Space B265 Space B266 Space B267 Space B269 Space P103 2 / E401 3 / E407 6 / E403 4 / E407 8 / E403 3 / E411 8 / E403 1 / E401 6 / E401 8 / E403 4 / E403 4 / E406 4 / E411 4 / E401 1 / E414 1 / E404 FCU-4 1 HPA3B- 2 HPA3B-5 HPA3B- 5 HPA3B-5 HPA3A- 1HPA3A- 1 H J K AA AD AG AH 45 L M N A1 A2 A3 3 2 1 AF AC AB M.8M.9 1.1 A3 A219 Space B127 Space B129 S2 A226 B4 A224 A3 A225 CORRIDOR A241 A2n A222 A1d A223 STAIR A3 23 A1d A221 A2m A220 B4 A218 S2 A216 A2f A214 S1a A217 ELEC. P102 Space B270 Space B271 Space B272 Space B273 Space P104 1 / E402 1 / E409 2 / E414 8 / E403 8 / E403 2 / E414 1 / E409 1 / E402 2 / E401 3 / E407 1 / E406 1 / E406 50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Issued / RevisedDate # Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site. KBSO Project Number: 20070 1344 South Rangeline Road Suite 202 Carmel, IN 46032 317.344.8044 9/3/2021 6:19:57 PM C:\Users\jbogenschutz\Documents\20070 The Corner MEP v19_jbogenschutz.rvt LRK Project Number: 01.18066.00 EP112a PARTIAL L02 ELECTRICAL PLANS -BLDG A The Corner Carmel, IN Checker Author 116th Street & Rangeline Carmel, INThe Corner Carmel, IN •01.18066.001/8" = 1'-0" PARTIAL BLDG A L02 NW ELECTRICAL PLAN 1 1/8" = 1'-0" PARTIAL BLDG A L02 NE ELECTRICAL PLAN2 SHEET KEYNOTES 1 PROVIDE NON-FUSED DISCONNECT AND 208V, 1PH, 30A CIRCUIT FOR FAN COIL UNIT. USE (2) #10 AND (1) #10 GND. 2 PROVIDE 120V, 20A DEDICATED CIRCUIT FOR ELECTRIC UNIT HEATER. 3 PROVIDE NON-FUSED DISCONNECT AND 208V, 1PH, 30A CIRCUIT FOR FAN COIL UNIT. USE (2) #8 AND (1) #10 GND. GENERAL NOTES A REFER TO SHEET E-000 FOR GENERAL ELECTRICAL NOTES, SYMBOLS AND ABBREVIATIONS. B REFER TO E-600 SERIES SHEETS FOR LOAD CENTER CIRCUIT SCHEDULES FOR EACH DWELLNG UNIT TYPE. C ALL RECEPTACLES SHOWN LOCATED ON BUILDING EXTERIOR OR ROOF SHOULD BE PROVIDED WITH IN-USE WEATHERPROOF ENCLOSURE. D ROOF TOP CONDENSING UNITS SERVING RESIDENT UNITS FED FROM ASSOCIATED APARTMENT LOAD CENTER. SEE ENLARGED UNIT PLANS IN E-400 SERIES DRAWINGS FOR CIRCUIT INFORMATION. E CONDUCTOR SIZES LISTED ARE ACCURATE FOR CIRCUITS UP TO 100' IN LENGTH. FOR CIRCUIT LENGTHS GREATHER THAN 100', UPSIZE CONDUCTORS AS NECESSARY TO LIMIT VOLTAGE DROP TO 3% OR LESS FROM PANEL. F CONTRACTOR TO PROVIDE (2) 3/4" MICRODUCTS AND (1) 3/8" SMOOTHBORE INNER DUCT WITH PULL STRINGS AND BUSHINGS FROM IDF TERMINAL BOARD TO EACH APARTMENT UNIT HOME NETWORK ENCLOSURE. G ALL TV LOCATIONS SHOWN TO RECEIVE (2) RJ45 JACKS WITH CAT 6 CABLING ROUTED FROM NEAREST IDF CLOSET UNLESS NOTED OTHERWISE. H PROVIDE FIRE STOP FOR ALL COMMUNICATION RACEWAYS THAT PENETRATE FIRE WALLS. I ALL COMMUNICATION CABLE TO BE INSTALLED AND TESTED ACCORDING TO BICSI STANDARDS. REPLACE ANY CABLING THAT DOES NOT PASS TESTING PRIOR TO FINAL TERMINATIONS. J ALL FIRE STROBES TO BE 75cd UNLESS NOTED OTHERWISE. K PROVIDE FLOW AND TAMPER SWITCHES FOR ALL FIRE RISERS AND STAND PIPES. COORDINATE LOCATIONS WITH FIRE SUPRESSION SYSTEM DESIGNER. 1 06.16.21 Permit Set 2 08.20.21 IFC Set 3 09.01.21 IFC Set 11/15/21