Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
EP113a - PARTIAL L03 ELECTRICAL PLANS - BLDG A
SSS S F FS TSS SS FFT HPA3B UH-1 HPA3B-11 HPA3B-12,14HPA3B-13HPA3B-13 HPA3B-13 HPA3B-13 HPA3B-13 HPA3B-13 A1 A2f alt 1 B314 S1a A317 A2g A312 A1b A315 A1d A313 B1e alt 1 A310 A1d A311 S1 alt 3 A308 S1 A309 Space B320 Space B321 TELECOMM. P103 A1 alt 3 A306 A1d A307 A2b A305 B1f alt1 A304 S1 alt1 A303 B3 alt1 A302 A1e A301 Space B330 Space B331 Space B332 Space B333 STAIR A2 A350 Space B335 CORRIDOR A340 4HPA3B-262 / E401 3 / E407 6 / E403 4 / E407 8 / E403 3 / E411 8 / E403 1 / E401 6 / E401 8 / E403 4 / E403 4 / E406 4 / E411 4 / E401 1 / E404 1 / E414 1 2 UH-1 HPA3A-11HPA3A-12 HPA3A-11 HPA3B-8,10 HPA3B- 9 HPA3B- 9 HPA3B- 9 K AA AD AG AH 45 A1 A2 A3 AF AC AB M.9 A3 alt1 A325 S2 A326 Space B298 STAIR A3 A349 A1d A323 B4 alt1 A324 A2n A322 A2m A320 B4 alt1 A318 A1d A321 Space B306 Space B307 Space B308 S2 A316 A2f alt 1 B314 S1a A317 Space B312 A3 alt1 A325 FCU-4 4 1 / E406 1 / E406 1 / E409 1 / E402 2 / E414 8 / E403 8 / E403 2 / E414 1 / E409 1 / E402 2 / E401 3 / E407 50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Issued / RevisedDate # Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site. KBSO Project Number: 20070 1344 South Rangeline Road Suite 202 Carmel, IN 46032 317.344.8044 9/3/2021 6:20:33 PM C:\Users\jbogenschutz\Documents\20070 The Corner MEP v19_jbogenschutz.rvt LRK Project Number: 01.18066.00 EP113a PARTIAL L03 ELECTRICAL PLANS -BLDG A The Corner Carmel, IN Checker Author 116th Street & Rangeline Carmel, INThe Corner Carmel, IN •01.18066.001/8" = 1'-0" PARTIAL BLDG A L03 NW ELECTRICAL PLAN1 1/8" = 1'-0" PARTIAL BLDG A L03 NE ELECTRICAL PLAN2 GENERAL NOTES A REFER TO SHEET E-000 FOR GENERAL ELECTRICAL NOTES, SYMBOLS AND ABBREVIATIONS. B REFER TO E-600 SERIES SHEETS FOR LOAD CENTER CIRCUIT SCHEDULES FOR EACH DWELLNG UNIT TYPE. C ALL RECEPTACLES SHOWN LOCATED ON BUILDING EXTERIOR OR ROOF SHOULD BE PROVIDED WITH IN-USE WEATHERPROOF ENCLOSURE. D ROOF TOP CONDENSING UNITS SERVING RESIDENT UNITS FED FROM ASSOCIATED APARTMENT LOAD CENTER. SEE ENLARGED UNIT PLANS IN E-400 SERIES DRAWINGS FOR CIRCUIT INFORMATION. E CONDUCTOR SIZES LISTED ARE ACCURATE FOR CIRCUITS UP TO 100' IN LENGTH. FOR CIRCUIT LENGTHS GREATHER THAN 100', UPSIZE CONDUCTORS AS NECESSARY TO LIMIT VOLTAGE DROP TO 3% OR LESS FROM PANEL. F CONTRACTOR TO PROVIDE (2) 3/4" MICRODUCTS AND (1) 3/8" SMOOTHBORE INNER DUCT WITH PULL STRINGS AND BUSHINGS FROM IDF TERMINAL BOARD TO EACH APARTMENT UNIT HOME NETWORK ENCLOSURE. G ALL TV LOCATIONS SHOWN TO RECEIVE (2) RJ45 JACKS WITH CAT 6 CABLING ROUTED FROM NEAREST IDF CLOSET UNLESS NOTED OTHERWISE. H PROVIDE FIRE STOP FOR ALL COMMUNICATION RACEWAYS THAT PENETRATE FIRE WALLS. I ALL COMMUNICATION CABLE TO BE INSTALLED AND TESTED ACCORDING TO BICSI STANDARDS. REPLACE ANY CABLING THAT DOES NOT PASS TESTING PRIOR TO FINAL TERMINATIONS. J ALL FIRE STROBES TO BE 75cd UNLESS NOTED OTHERWISE. K PROVIDE FLOW AND TAMPER SWITCHES FOR ALL FIRE RISERS AND STAND PIPES. COORDINATE LOCATIONS WITH FIRE SUPRESSION SYSTEM DESIGNER. SHEET KEYNOTES 1 PROVIDE NON-FUSED DISCONNECT AND 208V, 1PH, 30A CIRCUIT FOR FAN COIL UNIT. USE (2) #10 AND (1) #10 GND. 2 PROVIDE 120V, 20A DEDICATED CIRCUIT FOR ELECTRIC UNIT HEATER. 3 PROVIDE NON-FUSED DISCONNECT AND 208V, 1PH, 30A CIRCUIT FOR FAN COIL UNIT. USE (2) #8 AND (1) #10 GND. 4 PROVIDE BATTERY POWERED EMERGENCY INVERTER FOR EGRESS LIGHTING. USE MYERS EMERGENCY POWER SYSTEMS ILLUMINATOR LV-2-R-1-B20. 2 3 1 06.16.21 Permit Set 2 08.20.21 IFC Set 3 09.01.21 IFC Set 11/15/21