Loading...
HomeMy WebLinkAboutEP113b - PARTIAL L03 ELECTRICAL PLANS - BLDG AS S S S SFFT 1 ELEC. A344 MECH. A345 TELECOMM. A346 HPA3A UH-1 HPA3A- 6 HPA3A- 7HPA3A- 7 HPA3A- 7HPA3A- 7HPA3A- 7FCU-4HPA3A-8,10HPA3A-956 7 8 9 10 1213 A1 11 14 M.9 B-AB B-A2 B-A1 A1f A339 ELEV.A1 ? STAIR A1 A348 STORAGE A343 B1r A338 CORRIDOR A342 B1k A336 S1 alt2 A336 A1d A337 S1 A335 A1d A333 A1 alt2 A332 A1d A331 B1e A330 B1d alt1 A328 A1d A329 A1c A327 S2 A326 Space B296 Space B297 HPA3A-17 2 2 / E404 3 / E413 8 / E403 2 / E412 1 / E4091 / E401 5 / E401 8 / E403 3 / E403 8 / E403 8 / E403 7 / E403 2 / E411 1 / E411 1 / E402 50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Issued / RevisedDate # Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site. KBSO Project Number: 20070 1344 South Rangeline Road Suite 202 Carmel, IN 46032 317.344.8044 9/3/2021 6:20:49 PM C:\Users\jbogenschutz\Documents\20070 The Corner MEP v19_jbogenschutz.rvt LRK Project Number: 01.18066.00 EP113b PARTIAL L03 ELECTRICAL PLANS -BLDG A The Corner Carmel, IN Checker Author 116th Street & Rangeline Carmel, INThe Corner Carmel, IN •01.18066.001/8" = 1'-0" PARTIAL BLDG A L03 SE ELECTRICAL PLAN 1 GENERAL NOTES A REFER TO SHEET E-000 FOR GENERAL ELECTRICAL NOTES, SYMBOLS AND ABBREVIATIONS. B REFER TO E-600 SERIES SHEETS FOR LOAD CENTER CIRCUIT SCHEDULES FOR EACH DWELLNG UNIT TYPE. C ALL RECEPTACLES SHOWN LOCATED ON BUILDING EXTERIOR OR ROOF SHOULD BE PROVIDED WITH IN-USE WEATHERPROOF ENCLOSURE. D ROOF TOP CONDENSING UNITS SERVING RESIDENT UNITS FED FROM ASSOCIATED APARTMENT LOAD CENTER. SEE ENLARGED UNIT PLANS IN E-400 SERIES DRAWINGS FOR CIRCUIT INFORMATION. E CONDUCTOR SIZES LISTED ARE ACCURATE FOR CIRCUITS UP TO 100' IN LENGTH. FOR CIRCUIT LENGTHS GREATHER THAN 100', UPSIZE CONDUCTORS AS NECESSARY TO LIMIT VOLTAGE DROP TO 3% OR LESS FROM PANEL. F CONTRACTOR TO PROVIDE (2) 3/4" MICRODUCTS AND (1) 3/8" SMOOTHBORE INNER DUCT WITH PULL STRINGS AND BUSHINGS FROM IDF TERMINAL BOARD TO EACH APARTMENT UNIT HOME NETWORK ENCLOSURE. G ALL TV LOCATIONS SHOWN TO RECEIVE (2) RJ45 JACKS WITH CAT 6 CABLING ROUTED FROM NEAREST IDF CLOSET UNLESS NOTED OTHERWISE. H PROVIDE FIRE STOP FOR ALL COMMUNICATION RACEWAYS THAT PENETRATE FIRE WALLS. I ALL COMMUNICATION CABLE TO BE INSTALLED AND TESTED ACCORDING TO BICSI STANDARDS. REPLACE ANY CABLING THAT DOES NOT PASS TESTING PRIOR TO FINAL TERMINATIONS. J ALL FIRE STROBES TO BE 75cd UNLESS NOTED OTHERWISE. K PROVIDE FLOW AND TAMPER SWITCHES FOR ALL FIRE RISERS AND STAND PIPES. COORDINATE LOCATIONS WITH FIRE SUPRESSION SYSTEM DESIGNER. SHEET KEYNOTES 1 PROVIDE NON-FUSED DISCONNECT AND 208V, 1PH, 30A CIRCUIT FOR FAN COIL UNIT. USE (2) #10 AND (1) #10 GND. 2 PROVIDE BATTERY POWERED EMERGENCY INVERTER FOR EGRESS LIGHTING. USE MYERS EMERGENCY POWER SYSTEMS ILLUMINATOR LV-2-R-1-B20. 1 06.16.21 Permit Set 2 08.20.21 IFC Set 3 09.01.21 IFC Set 11/15/21