EP114a - PARTIAL L04 ELECTRICAL PLANS - BLDG A
F F SS SS S S TFFSS SS S T 3HPA5B-6 HPA5B- 6HPA5B-6HPA5B-6 HPA5B- 6HPA5B- 6 HPA5B-7HPA5B-8,10 A1 A2f A414 S1a A417 A1b A415 A2g A412 Space A392 TELECOMM. P104 A1d A413 B1e alt1 A410 A1d A411 S1 A409 S1 alt3 A408 A1 alt3 A406 A1d A407 A2b A405 B1f A404 S1 alt.1 A403 B3 A402 STAIR A2 P106 Space A408 Space A409 Space A410 A1e A401 Space A412 ELEV. A2 ? Space A414 FCU-5 2 / E401 3 / E407 6 / E403 4 / E407 8 / E403 3 / E411 8 / E403 1 / E401 6 / E401 8 / E403 4 / E403 4 / E406 4 / E411 4 / E401 1 / E404 1 / E414 1 HPA5A-11 HPA5A-11 HPA5B- 1 HPA5B-3,5 HPA5B-1 HPA5B-1K AA AD AG AH 45 A1 A2 A3 AF AC AB M.9 A3 A425 A1d A423 Space A375 Space A376 S2 A426 B4 A424 A2n A422 A2m A420 Space A381 A1d A421 A3 A419 B4 A418 Space A385 S2 A416 A2f A414 S1a A417 TELECOMM. P104 Space A394 Space A395 FCU-4 1 / E402 2 / E414 1 / E406 1 / E4061 / E409 8 / E403 8 / E403 2 / E414 1 / E409 1 / E402 2 / E401 3 / E407 50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Issued / RevisedDate # Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site. KBSO Project Number: 20070 1344 South Rangeline Road Suite 202 Carmel, IN 46032 317.344.8044 9/3/2021 6:21:07 PM C:\Users\jbogenschutz\Documents\20070 The Corner MEP v19_jbogenschutz.rvt LRK Project Number: 01.18066.00 EP114a PARTIAL L04 ELECTRICAL PLANS -BLDG A The Corner Carmel, IN Checker Author 116th Street & Rangeline Carmel, INThe Corner Carmel, IN •01.18066.001/8" = 1'-0" PARTIAL BLDG A L04 NW ELECTRICAL PLAN 1 1/8" = 1'-0" PARTIAL BLDG A L04 NE ELECTRICAL PLAN2 SHEET KEYNOTES 1 PROVIDE NON-FUSED DISCONNECT AND 208V, 1PH, 30A CIRCUIT FOR FAN COIL UNIT. USE (2) #10 AND (1) #10 GND. 2 PROVIDE 120V, 20A DEDICATED CIRCUIT FOR ELECTRIC UNIT HEATER. 3 PROVIDE NON-FUSED DISCONNECT AND 208V, 1PH, 30A CIRCUIT FOR FAN COIL UNIT. USE (2) #8 AND (1) #10 GND. GENERAL NOTES A REFER TO SHEET E-000 FOR GENERAL ELECTRICAL NOTES, SYMBOLS AND ABBREVIATIONS. B REFER TO E-600 SERIES SHEETS FOR LOAD CENTER CIRCUIT SCHEDULES FOR EACH DWELLNG UNIT TYPE. C ALL RECEPTACLES SHOWN LOCATED ON BUILDING EXTERIOR OR ROOF SHOULD BE PROVIDED WITH IN-USE WEATHERPROOF ENCLOSURE. D ROOF TOP CONDENSING UNITS SERVING RESIDENT UNITS FED FROM ASSOCIATED APARTMENT LOAD CENTER. SEE ENLARGED UNIT PLANS IN E-400 SERIES DRAWINGS FOR CIRCUIT INFORMATION. E CONDUCTOR SIZES LISTED ARE ACCURATE FOR CIRCUITS UP TO 100' IN LENGTH. FOR CIRCUIT LENGTHS GREATHER THAN 100', UPSIZE CONDUCTORS AS NECESSARY TO LIMIT VOLTAGE DROP TO 3% OR LESS FROM PANEL. F CONTRACTOR TO PROVIDE (2) 3/4" MICRODUCTS AND (1) 3/8" SMOOTHBORE INNER DUCT WITH PULL STRINGS AND BUSHINGS FROM IDF TERMINAL BOARD TO EACH APARTMENT UNIT HOME NETWORK ENCLOSURE. G ALL TV LOCATIONS SHOWN TO RECEIVE (2) RJ45 JACKS WITH CAT 6 CABLING ROUTED FROM NEAREST IDF CLOSET UNLESS NOTED OTHERWISE. H PROVIDE FIRE STOP FOR ALL COMMUNICATION RACEWAYS THAT PENETRATE FIRE WALLS. I ALL COMMUNICATION CABLE TO BE INSTALLED AND TESTED ACCORDING TO BICSI STANDARDS. REPLACE ANY CABLING THAT DOES NOT PASS TESTING PRIOR TO FINAL TERMINATIONS. J ALL FIRE STROBES TO BE 75cd UNLESS NOTED OTHERWISE. K PROVIDE FLOW AND TAMPER SWITCHES FOR ALL FIRE RISERS AND STAND PIPES. COORDINATE LOCATIONS WITH FIRE SUPRESSION SYSTEM DESIGNER. 1 06.16.21 Permit Set 2 08.20.21 IFC Set 3 09.01.21 IFC Set 11/15/21