Loading...
HomeMy WebLinkAboutEP115b - PARTIAL L05 ELECTRICAL PLANS - BLDG AS S S S SFFT S S S 1 STORAGE A543 ELEC. A544 MECH. A545 TELECOMM. A546 HPA5AUH-1 FCU-4 HPA5A-1,3 HPA5A- 2 HPA5A-4 HPA5A-4 2 HPA5A-10 HPA5A- 4 HPA5A-4 HPA5A-4 56 7 8 9 10 1213 A1 11 14 M.9 A1f A539 ELEV.A1 P108 STAIR A1 A548 CORRIDOR A542 B1r A538 B1k A536 A1d A537 S1 A535 S1 alt2 A534 A1 alt2 A532 A1d A533 A1d A531 B1e A530 B1d alt1 A528 A1d A529 A1c A527 Space P123 Space P124 HPA5A-17 HPA5A-18 3 4 HPA5A-5 2 / E404 3 / E413 8 / E403 2 / E412 1 / E401 5 / E401 8 / E403 3 / E403 8 / E403 8 / E403 7 / E403 2 / E411 1 / E411 1 / E402 1 / E409 50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Issued / RevisedDate # Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site. KBSO Project Number: 20070 1344 South Rangeline Road Suite 202 Carmel, IN 46032 317.344.8044 9/3/2021 6:21:58 PM C:\Users\jbogenschutz\Documents\20070 The Corner MEP v19_jbogenschutz.rvt LRK Project Number: 01.18066.00 EP115b PARTIAL L05 ELECTRICAL PLANS -BLDG A The Corner Carmel, IN Checker Author 116th Street & Rangeline Carmel, INThe Corner Carmel, IN •01.18066.001/8" = 1'-0" PARTIAL BLDG A L05 SE ELECTRICAL PLAN 1 SHEET KEYNOTES 1 PROVIDE NON-FUSED DISCONNECT AND 208V, 1PH, 30A CIRCUIT FOR FAN COIL UNIT. USE (2) #10 AND (1) #10 GND. 2 PROVIDE 120V, 20A DEDICATED CIRCUIT FOR ELECTRIC UNIT HEATER. 3 PROVIDE 208V, 3PH CIRCUIT TO ELEVATOR POWER UNIT ACCORDING TO ONE-DIAGRAM. PROVIDE 120V CIRCUIT AND TOGGLE DISCONNECT FOR ELEVATOR CAB POWER. PROVIDE 120V CIRCUIT AND TOGGLE DISCONNECT FOR ELEVATOR CONTROLLER. 4 PROVIDE BATTERY POWERED EMERGENCY INVERTER FOR EGRESS LIGHTING. USE MYERS EMERGENCY POWER SYSTEMS ILLUMINATOR LV-2-R-1-B20. GENERAL NOTES A REFER TO SHEET E-000 FOR GENERAL ELECTRICAL NOTES, SYMBOLS AND ABBREVIATIONS. B REFER TO E-600 SERIES SHEETS FOR LOAD CENTER CIRCUIT SCHEDULES FOR EACH DWELLNG UNIT TYPE. C ALL RECEPTACLES SHOWN LOCATED ON BUILDING EXTERIOR OR ROOF SHOULD BE PROVIDED WITH IN-USE WEATHERPROOF ENCLOSURE. D ROOF TOP CONDENSING UNITS SERVING RESIDENT UNITS FED FROM ASSOCIATED APARTMENT LOAD CENTER. SEE ENLARGED UNIT PLANS IN E-400 SERIES DRAWINGS FOR CIRCUIT INFORMATION. E CONDUCTOR SIZES LISTED ARE ACCURATE FOR CIRCUITS UP TO 100' IN LENGTH. FOR CIRCUIT LENGTHS GREATHER THAN 100', UPSIZE CONDUCTORS AS NECESSARY TO LIMIT VOLTAGE DROP TO 3% OR LESS FROM PANEL. F CONTRACTOR TO PROVIDE (2) 3/4" MICRODUCTS AND (1) 3/8" SMOOTHBORE INNER DUCT WITH PULL STRINGS AND BUSHINGS FROM IDF TERMINAL BOARD TO EACH APARTMENT UNIT HOME NETWORK ENCLOSURE. G ALL TV LOCATIONS SHOWN TO RECEIVE (2) RJ45 JACKS WITH CAT 6 CABLING ROUTED FROM NEAREST IDF CLOSET UNLESS NOTED OTHERWISE. H PROVIDE FIRE STOP FOR ALL COMMUNICATION RACEWAYS THAT PENETRATE FIRE WALLS. I ALL COMMUNICATION CABLE TO BE INSTALLED AND TESTED ACCORDING TO BICSI STANDARDS. REPLACE ANY CABLING THAT DOES NOT PASS TESTING PRIOR TO FINAL TERMINATIONS. J ALL FIRE STROBES TO BE 75cd UNLESS NOTED OTHERWISE. K PROVIDE FLOW AND TAMPER SWITCHES FOR ALL FIRE RISERS AND STAND PIPES. COORDINATE LOCATIONS WITH FIRE SUPRESSION SYSTEM DESIGNER. 1 06.16.21 Permit Set 2 08.20.21 IFC Set 3 09.01.21 IFC Set 11/15/21