Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
G111 - CODE SUMMARY - PODIUM BUILDING
VITREO US CHINABATHRO O M SINKVO XK-5373 VITREO US CHINABATHRO O M SINKVO XK-5373 UP VITREO US CHINABATHRO O M SINKVO XK-5373 VITREO US CHINABATHRO O M SINKVO XK-5373 CODE SUMMARY - PODIUM BUILDING OCCUPANT LOAD - 299 REQ'D # OF EXITS - 2 EXITS PROVIDED - 4 PODIUM BUILDING USE GROUP: ASSEMBLY A-2 15 SF/OCCUP. (NET) AREA: 4,474 SF OCCUPANT LOAD - 1380 REQ'D # OF EXITS - 4 EXITS PROVIDED - 18 PODIUM BUILDING USE GROUP: ASSEMBLY A-2 15 SF/OCCUP. AREA: 20,694 SF 1 G111 25 G111 Sim PODIUM BUILDING CONSTRUCTION TYPE: I-A NO. OF STORIES: 1 RETAIL / RESTAURANT SHELL SPACE SPRINKLER TYPE: NFPA 13 EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXITEXITEXITEXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT BLDG A L 05 +871' -10 1/16" BLDG A TRUSS BEARING +880' -11 3/16" BLDG A L 02 +839' -10 7/16" BLDG A L 03 +850' -6 5/16" BLDG A L 04 +861' -2 3/16" L M N UNIT CORRIDORUNIT UNIT CORRIDORUNIT UNIT CORRIDORUNIT UNIT CORRIDORUNIT RETAIL SHELL 1/2 HOUR RATED CORRIDOR WALL 1 HOUR RATED ROOF/CEILING 1 HOUR RATED FLOOR/CEILING 3 HOUR RATED FLOOR/CEILING BLDG A L 01.1 +818' -1 13/16"21'-8 3/4"PODIUM BUILDINGBUILDING A(SEE SHEET G112)TYPE VA CONSTRUCTIONTYPE IA CONSTRUCTION OCCUPANT LOAD - 107 REQ'D # OF EXITS - 2 EXITS PROVIDED - 5 LEASING / AMENITY USE GROUP: MIXED USE 45.58 SF/OCCUP. AREA: 4,876 SF USE GROUP B LEASING OFFICE, LOBBY 100 GROSS SF / OCCUPANT AREA : 1,399 SF OCCUPANT LOAD : 14 USE GROUP A-3 CLUB RM., SPORTS SIMULATOR 15 NET SF / OCCUPANT AREA : 1,074 SF OCCUPANT LOAD : 72 USE GROUP A-3 EXERCISE ROOM 50 GROSS SF / OCCUPANT AREA : 1,030 SF OCCUPANT LOAD : 21 EXIT EXIT EXIT EXIT TRAVEL DISTANCE 52'-6" TRAVEL DISTANCE 99'-3" EXIT EXIT MIXED USE OCCUPANCY, CONSTRUCTION TYPE I-A CHAPTER 5 -GENERAL BUILDING HEIGHT AND AREAS: SPECIAL PROVISION (510) HORIZONTAL BUILDING SEPARATION ALLOWANCE -3-HOURS HORIZONTAL SEPARATION, SINGLE STORY FOR TYPE I-A CONSTRUCTION WITH 2-HOUR SEPARATION FOR VERTICAL CIRCULATION PENETRATIONS CHAPTER 6 -TYPE OF CONSTRUCTION: TYPE OF CONSTRUCTION (SECTION 602): PODIUM BUILDING: TYPE I-A FIRE RESISTANCE REQUIREMENTS FOR BUILDING ELEMENTS (TABLE 601) PODIUM BUILDING STRUCTURAL FRAME:3 HR BEARING WALLS: EXTERIOR / INTERIOR:3 HR / 3 HR NON-BEARING WALLS EXTERIOR / INTERIOR:1 HR / 0 HR FLOOR CONSTRUCTION:2 HR ROOF CONSTRUCTION:1.5 HR FIRE RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE (TABLE 602) FOR GROUP R, THE BUILDING EXTERIOR IS OPEN ON 1 SIDE BY A PUBLIC RIGHT OF WAY, AND ON THE 3 SIDES BY A MINIMUM 20’SEPARATION. 5’≤X ≤10’:1 HR 10’≤X ≤30’:1 HR PROJECT DESCRIPTION: MIXED USE NON-SEPARATED OCCUPANCY, SPRINKLERED BUILDING PROJECT NAME AND ADDRESS:OWNER ADDRESS: THE CORNER BUCKINGHAM COMPANIES 116TH STREET AND RANGELINE ROAD 941 NORTH MERIDIAN STREET CARMEL, INDIANA INDIANAPOLIS, INDIANA 46204 CODE REFERENCE: CODE REVIEW JURISDICTION: STATE OF INDIANA, DEPARTMENT OF HOMELAND SECURITY, DIVISION OF FIRE & BUILDING SAFETY CITY OF CARMEL BUILDING AND CODE SERVICES ZONING ORDINANCE:CITY OF CARMEL UNIFIED DEVELOPMENT ORDINANCE (AMENDED FEBRUARY 26, 2018) BUILDING CODE:2014 INDIANA BUILDING CODE WITH LOCAL AMENDMENTS (IBC, 2012 EDITION) ENERGY CODE:2010 INDIANA ENERGY CONSERVATION CODE WITH LOCAL AMENDMENTS (ASHRAE 90.1, 2007 EDITION) ELECTRICAL CODE:2009 INDIANA ELECTRICAL CODE WITH LOCAL AMENDMENTS (NFPA 70-2008) MECHANICAL CODE:2014 INDIANA MECHANICAL CODE WITH LOCAL AMENDMENTS (IMC, 2012 EDITION) PLUMBING CODE:2012 INDIANA PLUMBING CODE WITH LOCAL AMENDMENTS (IPC, 2006 EDITION) FUEL GAS CODE:2014 INDIANA FUEL GAS CODE WITH LOCAL AMENDMENTS (IFGC, 2012 EDITION) ELEVATOR SAFETY CODE:AUTOMATED PEOPLE MOVER-PART I, PART 2, AND PART 3 -ANSI/ASCE/T & DI 21-08 AS AMENDED ZONING: ZONING DISTRICTS:C-1 DISTRICT PERMITTED USES:GENERAL RETAIL AND MULTIPLE FAMILY DWELLING PERMITTED BY RIGHT FIRE ZONE:NO FLOOD ZONES: PARKING: CHAPTER 3 -USE AND OCCUPANCY CLASSIFICATION: OCCUPANCY TYPE: RETAIL SHELL: A-2 (IBC, SECTION 303.3) LEASING / AMENITY:A-3 (IBC, SECTION 303.4) B (IBC, SECTION 304) CHAPTER 7 -FIRE RESISTANCE RATED CONSTRUCTION: MAXIMUM AREA OF EXTERIOR WALL OPENINGS (TABLE 705.8) IN BUILDINGS THAT HAVE A SEPARATION DISTANCE 20’≤X < 25’, ALLOWABLE AREA OF THE OPENINGS IS UNLIMITED. CONCEALED SPACES FIREBLOCKING:REQUIRED IN COMBUSTIBLE CONSTRUCTION TO MEET REQUIREMENTS OF SECTION 718.2 DRAFTSTOPPING:NOT REQUIRED IN FLOORS OR ATTIC PER SECTION 718.3.2, EXCEPTION 1 AND SECTION 718.4.2, EXCEPTION 2, RESPECTIVELY. CHAPTER 9 -FIRE PROTECTION SYSTEMS: AUTOMATIC SPRINKLER SYSTEM (903): NFPA 13 SYSTEM PROVIDED STANDPIPE SYSTEM (905.3.1): REQUIRED PORTABLE FIRE EXTINGUISHERS (906):LOCATED AS SHOWN IN LIFE SAFETY PLAN FIRE ALARM AND DETECTION SYSTEMS (907):REQUIRED AND INSTALLED IN ACCORDANCE WITH IBC AND NFPA 72. MANUAL FIRE ALARM BOX NOT REQUIRED WITH AUTOMATIC SPRINKLER SYSTEM. EMERGENCY ALARM SYSTEMS (908):NOT REQUIRED SMOKE CONTROL SYSTEMS (909):NOT REQUIRED SMOKE AND HEAT VENTS (910):NOT REQUIRED FIRE COMMAND CENTER (911):NOT REQUIRED CHAPTER 10 -MEANS OF EGRESS: CEILING HEIGHT (1003.2):7 FEET 6 INCHES MINIMUM PROTRUDING OBJECTS: UNLIMTED PROJECTION FOR OBJECTS MOUNTED ABOVE 80 INCHES AT ANY WALKING SURFACE (1003.3.1)LOCATED BETWEEN 27 AND 80 INCHES (1003.3.3) -ELEMENTS CANNOT PROJECT OVER A WALKING SURFACE MORE THAN 4 INCHES.HANDRAILS CAN PROJECT UP TO 4-1/2 INCHES FROM THE WALL. A BARRIER SHALL BE PROVIDED WHERE THE VERTICAL CLEARANCE IS LESS THAN 80 INCHES HIGH. THE LEADING EDGE OF SUCH A BARRIER SHALL BE LOCATED 27 INCHES MAXIMUM ABOVE THE FLOOR. FLOOR SURFACE:WALKING SURFACES SHALL BE SLIP RESISTANT UNDER FORESEEABLE CONDITIONS. THE WALKING (1003.4)SURFACE OF EACH ELEMENT IN THE MEANS OF EGRESS SHALL BE UNIFORMLY SLIP RESISTANT ALONG THE NATURAL PATH OF TRAVEL. ELEVATION CHANGE:CHANGE IN LEVEL IN THE MEANS OF EGRESS SHALL BE EITHER BY A RAMP OR A STAIR. THE PRESENCE (1003.5)AND LOCATION OF RAMPED WALKWAYS SHALL BE READILY APPARENT. WHERE A CHANGE IN LEVEL FOR MEANS OF EGRESS NOT EXCEEDING 21 INCHES IS ACHIEVED BY A STAIR, THE MINIMUM TREAD DEPTH OF SUCH STAIR SHALL BE 13 INCHES AND THE PRESENCE AND LOCATION OF EACH STEP SHALL BE READILY APPARENT. MEANS OF EGRESS THE PATH OF EGRESS TRAVEL ALONG A MEANS OF EGRESS SHALL NOT BE INTERRUPTED BY ANY BUILDING CONTINUITY:ELEMENT OTHER THAN A MEANS OF EGRESS COMPONENT.OBSTRUCTIONS SHALL NOT BE (1003.6)PLACED IN THE REQUIRED WIDTH OF A MEANS OF EGRESS EXCEPT PROJECTIONS PERMITTED BY THIS CHAPTER. THE REQUIRED CAPACITY OF A MEANS OF EGRESS SYSTEM SHALL NOT BE DIMINISHED ALONG THE PATH OF EGRESS TRAVEL. EXIT DOORWAY OVERALL DIAGONAL LENGTH OF SPACE WITH USE GROUP A-3 = 58'-1" ARRANGEMENT MINIMUM SEPARATION DISTANCE = 19'-4" (1015.2.1 WITH EXCEPTION #2)ACTUAL SEPARATION DISTANCE = 45-4" ALLOWABLE AREA INCREASE - FRONTAGE ALLOWABLE AREA - BASE ACTUAL HEIGHT ALLOWABLE HEIGHT TYPE OF CONSTRUCTION ALLOWABLE AREA - TOTAL ACTUAL AREA PER FLOOR (MAX.) MAXIMUM ALLOWABLE BUILDING AREA (506.2.3) ACTUAL BUILDING AREA PODIUM BUILDING TYPE I-A UNLIMITED 21'-9" (MAX.) / 1 ST. UNLIMITED - UNLIMITED 30,046 GSF UNLIMITED 30,046 GSF ALLOWABLE HEIGHT INCREASES - TOTAL ALLOWABLE HEIGHT UNLIMITED 50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Seal Issued / RevisedDate# Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site.9/3/2021 2:47:28 PM C:\Revit Projects\18066-Corner Carmel-CENTRAL-19_smatsumotoBZ9SZ.rvtLRK Project Number: 01.18066.00 G111 CODE SUMMARY -PODIUM BUILDING VWB RCHThe Corner Carmel, IN • 01.18066.00 The Corner - Building A 1685 E. 116th Street, Carmel, IN SCALE: 1" = 20'-0" 28 GROUND FLOOR LIFE SAFETY PLAN - PODIUM BUILDING SCALE: 1" = 10'-0" 1 LIFE SAFETY SECTION - PODIUM BUILDING SCALE: 1/8" = 1'-0" 25 GROUND FLOOR LIFE SAFETY PLAN - LEASING / AMENITY 06.16.21 Permit Set C 09.01.21 IFC Set