Loading...
HomeMy WebLinkAboutID-7.01A40" MAX. TO REFL. SURFACE2'-8"MIRROR FAUCET 3/4" SHEATHING MILLWORK PANEL 8" MIN.9" MIN.11" MIN.6" MAX. 2'-0"5"2'-3" MIN TILE ON APPROVED SUBSTRATE CONT. BEAD OF SEALANT TO MATCH COUNTERTOP TILE ON APPROVED SUBSTRATE 75" TV - COORDINATE WITH A.V. CONSULTANT FOR DIMENSIONS 2X BLOCKING FOR TV MOUNTING HARDWARE TYP. PAINTED WD TRIM PAINTED GYP BOARD REMOVABLE SINK COVER TO MATCH CABINET 8" MIN.9" MIN.11" MIN. 1X WOOD BLOCKING TYP. FIN FLR BASE AS SCHEDULED PAINTED GYP BOARD 1 1/2"2'-10" MAX 1/4" 2'-0" MAX 2'-3" MIN 6" MAX TILE ON APPROVED SUBSTRATE3"3" 3'-6 3/4"1'-10 7/8" WD TRIM BEYOND STONE COUNTERTOP WITH EASED EDGE 3/4" PLYWOOD SUBSTRATE 3 1/2"TO CENTER OF TV2 1/4" 2 1/4"FINISHED CAB BEYOND6'-6"PAINTED GYP 1X WOOD BLOCKING ADJ SHELVES 2'-0" 3" 3/4" PLYWOOD UNDERLAY CONT. BEAD OF SEALANT TO MATCH COUNTERTOP STONE COUNTERTOP WITH EASED EDGE 1X WOOD BLOCKING TYP. KICK TO MATCH MILLWORK 1/4" CLOSURE PANEL FIN FLR 4" 1 1/2"2'-6" ADJ SHELVING 1'-10" 3'-0" PAINTED GYP BD CEILING HT REF. CEILING PLAN 1'-0" CONT. BEAD OF SEALANT TO MATCH COUNTERTOP STONE COUNTERTOP WITH EASED EDGE FIN FLR 2'-0"PLYWOOD SUBSTRATE 1 1/2"WOOD BLOCKING TYP. CONCEALED BRACKETS FOR SUPPORT AS REQUIRED BASE AS SCHEDULED 27" MINPAINTED GYP BD 2'-6"FINISHED CABINET BEYOND PAINTED GYP 1X WOOD BLOCKING ADJ SHELVES 3'-0"CEILING HT REF. CEILING PLAN 1'-0"1'-10" BASE AS SCHEDULED WALLCOVERING NOTE: PRIOR TO FRAMING AND INSTALLATION OF POWER, CONTRACTOR SHALL VERIFY ACTUAL TELEVISION AND TV MOUNT MANUFACTURE. LOCATE TV POWER BELOW MOUNT AND CONCEAL CABLES BEHIND TELEVISION TV - COORDINATE WITH A.V. CONSULTANT FOR DIMENSIONS 2X BLOCKING FOR TV MOUNTING HARDWARE TYP. PAINTED WD TRIM PAINTED GYP BOARD 3"3" 3'-7"PAINTED WD TRIM BEYOND 3'-8 1/2" 5'-6"FIN FLR 3 1/2"TO CENTER OF TV2 1/4"2 1/4" 01SECTION DETAIL CLUB1" = 1'-0" 02 SECTION DETAIL CLUB1" = 1'-0" 03 SECTION DETAIL LEASING1" = 1'-0" 04 MILLWORK SECTION WORK ROOM1" = 1'-0" 05 MILLWORK SECTION WORK ROOM1" = 1'-0" 06SECTION DETAIL RESTROOM1" = 1'-0"2'-10"PAINTED GYP BD TILE ON APPROVED SUBSTRATE FIN FLR WALLCOVERING TILE ON WATERPROOF SUBSTRATE TILE ON WATERPROOF SUBSTRATE SCHLUTER JOLLY EDGE PROFILE IN SATIN NICKEL SIZED AS APPROPRIATE AT NICHE PERIMETER TILE ON WATERPROOF SUBSTRATE 2'-11 1/2" 1'-1 1/2"4 3/8" 4" FINISH FLOOR 07SECTION DETAIL RESTROOM1" = 1'-0"TO CENTER OF TVFIN FLR FIREPLACE - REF MFR INSTALLATION AND SAFETY REQUIREMENTS TILE ON APPROVED SUBSTRATE FRAMING AS REQUIRED 5'-6"PAINTED PLYWOOD TILE ON APPROVED SUBSTRATE 75" TV - COORDINATE WITH A.V. CONSULTANT FOR DIMENSIONS 2X BLOCKING FOR TV MOUNTING HARDWARE TYP. NOTE: PRIOR TO FRAMING AND INSTALLATION OF POWER, CONTRACTOR SHALL VERIFY ACTUAL TELEVISION AND TV MOUNT MANUFACTURE. LOCATE TV POWER BELOW MOUNT AND CONCEAL CABLES BEHIND TELEVISION TILE ON APPROVED SUBSTRATE TILE ON APPROVED SUBSTRATE TILE ON APPROVED SUBSTRATE PAINTED PLYWOOD PAINTED PLYWOOD SCHLUTER SCHLUTER SCHLUTER SCHLUTER 8" 1'-8" VERIFY RE FIREPLACE MFR 1'-5" EQ 3'-6" EQ4"4" 3'-2" 8" 9" ID-7.01A/10 ID-7.01A/11 08SECTION DETAIL FITNESS1" = 1'-0" ID-7.01A/12 4" 3'-6" 4" 3'-6" 4"4" 7'-8" 2" 8" 2" 3'-2" 4"ID-7.01A/0909SECTION DETAIL FITNESS1" = 1'-0" MIRROR MIRROR PAINTED PLYWOOD 2" 8" 2"MIRROR J-CHANNEL SIZED AS APPROPRIATE PAINTED 1/2" PLY 1x PAINTED APPLIED GRILL ON 1x BACKER 1x PAINTED APPLIED GRILL ON 1x BACKER J-CHANNEL SIZED AS APPROPRIATE MIRROR 4"MIRROR J-CHANNEL SIZED AS APPROPRIATE 1x PAINTED APPLIED GRILL ON 1x BACKER 10SECTION DETAIL FITNESS 3" = 1'-0" 11SECTION DETAIL FITNESS3" = 1'-0" FIN FLR 12SECTION DETAIL FITNESS3" = 1'-0"4"1x PAINTED APPLIED GRILL ON 1x BACKER J-CHANNEL SIZED AS APPROPRIATE MIRROR THIN BRICK 2"1x PLYWOOD BACKER FOR MIRROR 3/4"3/4" 1/4" PAINTED HARDWOOD EDGE ID-7.01A SECTIONS & DETAILS BUILDING A 1" = 1'-0" CLIENT / DEVELOPER: PROJECT CONTACTS: PROJECT NAME: ISSUE LOG: SHEET NUMBER: DRAWING NAME: THE INTERIOR DESIGN PLANS AND SPECIFICATIONS ISSUED FOR THIS PROJECT HAVE BEEN PREPARED BY SJL DESIGN GROUP (SJL) FROM DATA PROVIDED BY THE REPRESENTATIVE OF THE CLIENT. THE COMPLETENESS AND ACCURACY OF THIS DATA HAS BEEN RELIED UPON BY SJL. INTERIOR AND PRODUCT DESIGNS ARE SUBJECT TO MODIFICATIONS OR CHANGES DUE TO FIELD VERIFICATIONS, EXISTING OR OTHER CONDITIONS AND BUILDING CODE REQUIREMENTS. THE DEVELOPER/CLIENT SHALL BE RESPONSIBLE FOR OBTAINING ALL REQUIRED PERMITS FOR THE PROJECT AND FOR COMPLIANCE WITH ALL LOCAL, STATE AND FEDERAL CODES. IN THE EVENT THE PLANS AND/OR SPECIFICATIONS ARE REQUIRED TO BE SEALED BY A LICENSED PROFESSIONAL, IT IS THE RESPONSIBILITY OF THE DEVELOPER/CLIENT TO RETAIN A LICENSED PROFESSIONAL TO SIGN AND SEAL THE PLANS. SJL SHALL NOT BE RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS TO THE PLANS AND SPECIFICATIONS UNLESS EXPRESSLY APPROVED BY SJL IN WRITING.THE CORNER116TH STREET & RANGELINECARMEL, INDIANA 46032PROJECT NUMBER: 118-1198 BUCKINGHAM COMPANIES 30 SOUTH MERIDIAN STREET, SUITE 1100 INDIANAPOLIS, INDIANA 46204 T: 317.974.1234 PROJECT ISSUE / DATE: IFC SET - BUILDING A SEPTEMBER 01, 2021 SCALE: ISSUE DATES: LRK 50 SOUTH B.B. KING BLVD. SUITE 600 MEMPHIS, TN 38103 T: 901.521.1440 ARCHITECT: STACY MILLER (PRINCIPAL) ANNA KARCHER (PROJECT MANAGER) KEY PLAN: 9 2 1 N . R I V E R F R O N T B L V D. S U I T E 1 0 0 D A L L A S , T E X A S 7 5 2 0 7 T: 2 1 4 . 4 4 3 . 9 0 9 0 F: 2 1 4 . 9 7 5 . 1 0 4 4 NOT FOR CONSTRUCTION - ©2021 SJL DESIGN GROUP PERMIT SET 06.16.2021 IFC SET - BUILDING B 08.20.2021B C IFC SET - BUILDING A 09.01.2021 11/15/21