Loading...
HomeMy WebLinkAboutL505 Site Details - 1391-L505Client: The Corner Carmel, IN Seal LRK Project Number: 00.18066.00 Project Name: 116th Street & Rangeline Carmel, IN Drawing Name: Drawn By: Checked By: © 2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not sacle drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site. Issues and Revisions Date Issued / Revised 06.16.21 Permit Set ɑ LM APP 5825 Lawton Loop East Drive | Indianapolis, IN 46216 317-485-6900 | www.context-design.com L505 FIRE HEARTH DETAILS 1 FIRE HEARTH Scale: 3/4" = 1'-0" 8'-0" 6" Min. TYPICAL SIDE ELEVATION Outdoor Flat Screen TV, Final Size TBD By Owner. Refer to Specification for Basis of Design TV. Provide internal electrical connection. Superior Double Sided Outdoor Gas Fireplace Insert w/ SS Face Trim. Provide power and gas connection Porcelain Tile Veneer. Adhere to Face of Structure. Refer to Specification 04 43 00 1'-6" 1'-6 1/4" 11'-0" GENERAL FRAMING NOTES: 1. Vertical studs and the header for fire place insert must be metal. Steel preferred. 2. All remaining framing material may be wood. Combustible materials can be laid against the side and back standoffs and the stove base. 3. Ensure access to gas and electrical for all power and gas connections during framing, fire place installation, and finishing. 4. Fire place insert is not required to be completely enclosed in a chase. Maintain clearances from vent to combustible materials, as required. Outlet with Weatherproof Cover, Both Sides of Hearth TYPICAL FRONT ELEVATION Finish Grade Concrete Emergency Shutoff Timer Switch Ignition Switch 2x4 Metal Frame Studs Per Manufacturer's Requirements Empire Boulevard Ventless Gas Fireplace Insert w/ SS Face Trim - 60" Coordinate Gas & Electric Connection With MEP 2x4 Studs Approximate TV Screen Location for Reference Notes: 1. Basis of design stud material to be metal. 2. Coordinate final framing plan w/ manufacturer requirements. Adhere to minimum clearances & non-combustible areas per manufacturer. 3. Contractor shall provide shop drawings of framing plan for final approval prior to construction. FIRE HEARTH - FRAMING PLAN Scale: 3/4" = 1'-0" 1'-3 1/4" 7'-9" Concrete Mounting Curb Framing Stud Durock Cement Board Veneer Mortar Tile Veneer Tile Grout PLAN VIEW (2) Outdoor Flat Screen TV, Final Size TBD By Owner. Refer to Specification for Basis of Design TV. Provide internal electrical connection. 6'-5 12" tall edge platform 11'-0"0"5'-0"6'-5 5/8" 3'-0 1/4"1'-7 3/8" 3'-0"6'-5 1/2" 6'-4"1'-6"1'-6" 1'-6" 1'-2 1/8" typ.5'-0"3'-0 1/4" 9" 1'-6" Granite Seat Granite Seat1'-6 1/4" 1'-6"1'-6" 4'-6 1/4"8'-0"3'-2"4'-5 1/4"1'-4 3/4" typ.4'-10 1/2"6'-4" 9" 9" 9"8 5/8" 11/15/21