M111a - PARTIAL L01 MECHANICAL PLANS - BLDG A
UH-1 1 SEE THIS SHEET FOR CONTINUATION UH-6 UH-633 A1 UH-11 6 6 6 6 6 SEE SHEET M111b FOR CONTINUATION SEE THIS SHEET FOR CONTINUATION UH-4 2 4 LVR -2 EG-2 5 1.1 1 UH-1 6 6 6 6 50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Issued / RevisedDate # Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site. KBSO Project Number: 20070 1344 South Rangeline Road Suite 202 Carmel, IN 46032 317.344.8044 9/3/2021 12:24:07 PM C:\Users\Slove\Documents\20070 The Corner MEP v19_SamuelLove.rvt LRK Project Number: 01.18066.00 M111a PARTIAL L01 MECHANICAL PLANS -BLDG A The Corner Carmel, IN SJO SLL 116th Street & Rangeline Carmel, INThe Corner Carmel, IN •01.18066.00GENERAL NOTES A REFER TO SHEET M-000 FOR GENERAL MECHANICAL NOTES, SYMBOLS AND ABBREVIATIONS. B REFERENCE SHEET M-500 SERIES FOR MECHANICAL DETAILS. C REFERENCE SHEET M-600 SERIES FOR MECHANICAL SCHEDULES. D NOT ALL UNIT PLANS MAY BE APPLICABLE TO THIS BUILDING. E PROVIDE MECHANICAL SYSTEMS IN COMPLIANCE WITH STATE AND LOCAL CODES. F COORDINATE WITH STRUCTURAL AND FRAMING PLANS PRIOR TO COMMENCING WORK. COORDINATE ALL ROUTING WITH ALL TRADES PRIOR TO FABRICATION. G SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS AND TYPES OF RATED CONSTRUCTION TO MAINTAIN CONSTRUCTION RATING. H THERMOSTATS TO BE LOCATED 44-INCHES A.F.F. OR ALIGNED TO ADJACENT LIGHT SWITCHES. I DRYER AND BATHROOM EXHAUST DUCTWORK TO BE MINIMUM 26 GAUGE. J SEAL ALL FLOOR, CEILING, AND WALL PENETRATIONS. USE FIRE CAULK AT RATED ASSMEBLIES AND GENERAL SEALANT ELSEWHERE. WHERE NON-METALLIC COMPONENTS LARGER THAN 4"ø (I.E. PVC OR CONDUIT) PENETRATES RATED ASSEMBLIES, INSTALL INTUMESCENT COLLAR, WHERE DUCTWORK LARGER THAN 4"ø PENETRATES RATED ASSEMBLIES, INSTALL FIRE DAMPER. K SIZE AND INSTALL REFRIGERANT PIPING AND ACCESSORIES PER MANUFACTURER RECOMMENDATIONS. L ALL EXTERIOR VENT CAP AND VENT HOOD COLORS TO BE APPROVED IN SHOP DRAWINGS. M ALL FAN COIL UNITS TO BE MOUNTED TO WALL UNLESS NOTED OTHERWISE. COORDINATE MOUNTING HEIGHT WITH OTHER TRADES AND SPACE. N THE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING A SIGN ATTACHED TO THE DRYER BOX IN EACH APARTMENT. THE TAG SHALL DOCUMENT THE ASSOCIATED INSTALL DRYER VENT AND READ FOLLOWS: CONNECTED VENT DUCT: STRAIGHT DUCT: X-FEET, 90-DEGREE ELBOWS: COUNT = X, 45-DEGREE ELBOWS: COUNT - X. 1/8" = 1'-0" PARTIAL BLDG A L01 NW MECHANICAL PLAN1 1/8" = 1'-0" PARTIAL BLDG A L01 NE MECHANICAL PLAN2 SHEET KEYNOTES 1 MOUNT UNIT HEATER 8-INCHES A.F.F. 2 MOUNT UNIT HEATER WITH WALL BRACKET PER MANUFACTURER'S RECOMMENDATION. 3 UNIT HEATER TO BE MOUNTED ABOVE CEILING TO HEAT SOFFIT. THERMOSTAT TO ACTIVATE AT 37 DEGREES. 4 PROVIDE AND INSTALL LOUVERS PER ARCHITECTS APPROVAL OF HEIGHT. 5 12"x12" EXHAUST DUCT UP IN CHASE TO FAN ON ROOF. 6 PROVIDE TWO 6-INCH CONDUITS FROM ROOF TO FUTURE RETAIL SPACE FOR FUTURE MECHANICAL EQUIPMENT. 1 06.16.21 Permit Set 2 09.01.21 IFC Set 11/15/21