Loading...
HomeMy WebLinkAboutM111b - PARTIAL L01 MECHANICAL PLANS - BLDG AT T T U.C.ICE DISHWASHER MICRO. U.C. REF U.C.TRASH U.C.TRASHENGRAIN TV65" TV RECESSED 65"TVRECESSED 75"TVU.C.TRASHSJL TO COORD.CONTRACTORTO PROCURE & INSTALL--JANITOR VITREOUSCHINABATHROOMSINK VOXK-5373 VITREOUSCHINABATHROOMSINK VOX K-5373 2 M111b SG-3SG-3 -200 SG-3SG-3 -200 SG-3SG-3 -200 SG-3SG-3 -200 SG-3SG-3 -200 SG-3SG-3 -200 SG-3SG-3 -200 SG-3SG-3 -200 SG-3SG-3 -200 SG-1SG-1 -100 SG-3SG-3 -200 SG-3SG-3 -100 SG-3SG-3 -100 SG-3SG-3 -100 SG-3SG-3 -200SG-3SG-3 -100 8ø 8ø 8ø 8ø 8ø 12/10 14/12 16/12 RG-7 SG-1SG-1 -100 SG-1SG-1 -50 SG-1SG-1 -50 10ø 6ø 6ø 8ø 10ø 6ø 10ø 6ø 12/10 6ø SG-1SG-1 -100 16/14 16/14 14/12 8ø 6ø 6ø 8ø 8ø 8ø 10ø 6ø 8ø 10ø 16/12 6ø14/10 4ø 6ø EF-1 4ø 4ø FCU-7 FCU-6 FCU-6 16/12 LVR-5 1 1 1 10ø 2 2 2 3 4 4 UH-2 UH-2 6 6 SEE SHEET M111a FOR CONTINUATION UH-6 UH-67 7 UH-1 5 EF-1 4 EF-1 8 8 RG-7 RG-7 16/12 6ø SG-1SG-1 -100 SG-1SG-1 -200 12ø 12ø 12 11 LVR -7 10ø FCU-7FCU-6FCU-68ø 8ø8ø 14/16 16/12 16/1214/16 16/12 10ø 16/12150 CFM O.A.140 CFM O.A.140 CFM O.A.FCU-7 FCU-6 FCU-6 EF-1 EF-1 UH-1 EF-6 10/10 EG-2 LVR-3 UH-4 9 10 50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Issued / RevisedDate # Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site. KBSO Project Number: 20070 1344 South Rangeline Road Suite 202 Carmel, IN 46032 317.344.8044 9/3/2021 12:25:06 PM C:\Users\Slove\Documents\20070 The Corner MEP v19_SamuelLove.rvt LRK Project Number: 01.18066.00 M111b PARTIAL L01 MECHANICAL PLANS -BLDG A The Corner Carmel, IN SJO SLL 116th Street & Rangeline Carmel, INThe Corner Carmel, IN •01.18066.00GENERAL NOTES A REFER TO SHEET M-000 FOR GENERAL MECHANICAL NOTES, SYMBOLS AND ABBREVIATIONS. B REFERENCE SHEET M-500 SERIES FOR MECHANICAL DETAILS. C REFERENCE SHEET M-600 SERIES FOR MECHANICAL SCHEDULES. D NOT ALL UNIT PLANS MAY BE APPLICABLE TO THIS BUILDING. E PROVIDE MECHANICAL SYSTEMS IN COMPLIANCE WITH STATE AND LOCAL CODES. F COORDINATE WITH STRUCTURAL AND FRAMING PLANS PRIOR TO COMMENCING WORK. COORDINATE ALL ROUTING WITH ALL TRADES PRIOR TO FABRICATION. G SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS AND TYPES OF RATED CONSTRUCTION TO MAINTAIN CONSTRUCTION RATING. H THERMOSTATS TO BE LOCATED 44-INCHES A.F.F. OR ALIGNED TO ADJACENT LIGHT SWITCHES. I DRYER AND BATHROOM EXHAUST DUCTWORK TO BE MINIMUM 26 GAUGE. J SEAL ALL FLOOR, CEILING, AND WALL PENETRATIONS. USE FIRE CAULK AT RATED ASSMEBLIES AND GENERAL SEALANT ELSEWHERE. WHERE NON-METALLIC COMPONENTS LARGER THAN 4"ø (I.E. PVC OR CONDUIT) PENETRATES RATED ASSEMBLIES, INSTALL INTUMESCENT COLLAR, WHERE DUCTWORK LARGER THAN 4"ø PENETRATES RATED ASSEMBLIES, INSTALL FIRE DAMPER. K SIZE AND INSTALL REFRIGERANT PIPING AND ACCESSORIES PER MANUFACTURER RECOMMENDATIONS. L ALL EXTERIOR VENT CAP AND VENT HOOD COLORS TO BE APPROVED IN SHOP DRAWINGS. M ALL FAN COIL UNITS TO BE MOUNTED TO WALL UNLESS NOTED OTHERWISE. COORDINATE MOUNTING HEIGHT WITH OTHER TRADES AND SPACE. N THE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING A SIGN ATTACHED TO THE DRYER BOX IN EACH APARTMENT. THE TAG SHALL DOCUMENT THE ASSOCIATED INSTALL DRYER VENT AND READ FOLLOWS: CONNECTED VENT DUCT: STRAIGHT DUCT: X-FEET, 90-DEGREE ELBOWS: COUNT = X, 45-DEGREE ELBOWS: COUNT - X. SHEET KEYNOTES 1 FAN COIL UNIT TO BE HUNG ON WALL PER MANUFACTUERERS RECOMMENDATIONS. ROUTE REFRIGERANT LINES FROM CONDENSING UNIT ON ROOF. 2 THERMOSTAT MOUNTED AT 44-INCHES A.F.F. OR ALIGNED TO ADJACENT LIGHT SWITCHES. 3 PROVIDE A DOUBLE LOUVERED VENT CAP EQUAL TO "X-VENT DHEB-46". TERMINATE A MINIMUM OF 3-FEET FROM ANY OPERABLE OPENING. 4 EXHAUST FAN TO BE MOUNTED 8-FEET A.F.F. 5 MOUNT UNIT HEATER ON WALL 1-FOOT A.F.F. 6 MOUNT UNIT HEATER ON WALL BRACKET 7-FEET A.F.F. 7 UNIT HEATER TO BE MOUNTED ABOVE CEILING TO HEAT SOFFIT. THERMOSTAT TO ACTIVATE AT 37 DEGREES. 8 PROVIDE TWO 6-INCH CONDUITS FROM ROOF TO FUTURE RETAIL SPACE FOR FUTURE MECHANICAL EQUIPMENT. 9 MOUNT UNIT HEATER ON WALL BRACKET 7-FEET A.F.F. 10 MOUNT LOUVER CENTERED ABOVE DOOR. 11 PROVIDE ALL VENTILATION AND EXHAUST FOR GAS FIREPLACE PER MANUFACTURERS RECOMMENDATIONS. 12 PROVIDE FIREPLACE EXHAUST WITH PRODIGY INLINE POWER VENT MODEL PCINGPV-L03-12. INSTALL PER MANUFACTURERS RECOMMENDATIONS. 1/8" = 1'-0" PARTIAL BLDG A SE MECHANICAL PLAN1 3/8" = 1'-0" AMENITY MECHANICAL ROOM2 AMENITY AREA MECHANICAL ISOMETRIC3 1/4" = 1'-0" POOL SHED MECHANICAL PLAN 4 1 06.16.21 Permit Set 2 09.01.21 IFC Set 11/15/21