Loading...
HomeMy WebLinkAboutA351BLDG B L 02 +830' -8 23/32" BLDG B L 03 +841' -4 19/32" BLDG B L 01 +820' -0 27/32" BLDG B L 04 +852' -0 15/32" BLDG B TRUSS BEARING +861' -1 19/32" UNIT UNIT UNIT UNIT UNIT UNIT UNIT UNIT E E E T.O. CONC. SLAB TO B.O. TRUSS 9'-1 1/8" TRUSS 1'-6" 3/4" SUBFLOORT.O. SUBFLOOR TO B.O. TRUSS 9'-1 1/8" TRUSS 1'-6" 3/4" SUBFLOOR T.O. SUBFLOOR TO B.O. TRUSS 9'-1 1/8" TRUSS 1'-6" 3/4" SUBFLOORT.O. SUBFLOOR TO B.O. TRUSS9'-1 1/8"T.O. CONC. SLAB TO T.O. SUBFLOOR 10'-7 7/8" T.O. SUBFLOOR TO T.O. SUBFLOOR 10'-7 7/8" T.O. SUBFLOOR TO T.O. SUBFLOOR10'-7 7/8"T.O. CONC. SLAB TO T.O. TOPPING 10'-9 1/8" T.O. TOPPING TO T.O. TOPPING 10'-7 7/8" T.O. TOPPING TO T.O. TOPPING10'-7 7/8"1 1/4" TOPPING1 1/4" TOPPING 1 1/4" TOPPING 1A E 1A 1A 3 7 A350 7 A351 CORRIDOR UNIT TELE. COMM. CORRIDOR UNIT UNIT CORRIDOR UNIT UNIT CORRIDOR UNIT UNIT 3 1A 1A 1A C C CC CC CC 25 A351 COORDINATE TRUSS CONFIGURATION WITH MECHANICAL DUCT SIZING UNIT UNIT UNIT UNIT UNIT UNIT UNIT UNIT D D D D 1A 1A 1A 3 19 A351 SOLID MINERAL WOOL FIRESTOPPING 1" AIR SPACE 2 LAYERS OF 1" DENSGLASS SHAFTLINER PANELS SOLID MINERAL WOOL FIRESTOPPING FLOOR/ CEILING SYSTEM AS SCHEDULED WALL AS SCHEDULED BACKER ROD AND SEALANT, BOTH SIDES ACOUSTICAL SEALANT BOTH SIDES, TAPE AND MUD OVER SEALANT JOINT WHERE EXPOSED TO VIEW 3" SOUND BATT INSULATION EACH SIDE BACKER ROD AND SEALANT BOTH SIDES PLYWOOD SHEAR PANEL, RE: STRUCTURAL FLOOR/ CEILING SYSTEM AS SCHEDULED WALL AS SCHEDULED WALL AS SCHEDULED ACOUSTICAL SEALANT BOTH SIDES, TAPE AND MUD OVER SEALANT JOINT WHERE EXPOSED TO VIEW 3" SOUND BATT INSULATION EACH SIDE BACKER ROD AND SEALANT BOTH SIDES GYPSUM BOARD DRAFTSTOPPING FLOOR/ CEILING SYSTEM AS SCHEDULED WALL AS SCHEDULED WALL AS SCHEDULED ACOUSTICAL SEALANT BOTH SIDES, TAPE AND MUD OVER SEALANT JOINT WHERE EXPOSED TO VIEW 3" SOUND BATT INSULATION EACH SIDE 50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Seal Issued / RevisedDate # Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site.8/31/2021 1:29:41 PM C:\Revit Projects\18066-Corner Carmel-CENTRAL-19_smatsumotoBZ9SZ.rvt LRK Project Number: 01.18066.00 A351 BLDG B -RATED WALL SECTIONS The Corner Carmel, IN VWB SWMThe Corner Carmel, IN •01.18066.001685 E. 116th Street, Carmel, IN SCALE: 3/8" = 1'-0" 29 2 HR RATED FIRE WALL SCALE: 3/8" = 1'-0" 27 TYP. UNIT WALL -CORRIDOR WALL SCALE: 3/8" = 1'-0" 28 TYP. UNIT DEMISING WALL SCALE: 3" = 1'-0" 7 FIREWALL AT FLOOR/CEILING ASSEMBLY SCALE: 3" = 1'-0" 19 UNIT DEMISING WALL AT FLOOR/CLG ASSEMBLY SCALE: 3" = 1'-0" 25 UNIT CORRIDOR WALL AT FLOOR/CLG ASSEMBLY 06.16.21 Permit Set B 08.20.21 IFC Set 11/01/21