HomeMy WebLinkAboutA5211'-0" METAL PARAPET COPING WITH DRIP EDGE WOOD BLOCKING SELF ADHERED MEMBRANE FLASHING CONNECTING ROOFING MEMBRANE TO WEATHER BARRIER EXTERIOR SHEATHING 2" RIGID INSULATION 1/4" GAP BETWEEN FLASHING AND SIDING -DO NOT PROVIDE SEALANT SINGLE PLY ROOFING MEMBRANE, EXTEND OVER PARAPET WALL PARAPET FRAMING, RE: STRUCTURAL COVER BOARD 7 1/4" CROWN MOULD 1X2 FIBER CEMENT TRIM 2X4 TREATED FRAMING 1X8 FIBER CEMENT TRIM FIBER CEMENT SOFFIT PANEL 1X4 FIBER CEMENT TRIM 1X TREATED WOOD BLOCKING ROOF TRUSSES, RE: STRUCTURAL WEATHER BARRIER EXTERIOR SHEATHING 2X TREATED FRAMING METAL FLASHING WITH DRIP EDGE SET IN CONTINUOUS BED OF SEALANT R-13 BATT INSULATION SELF-ADHERED HIGH TEMPERATURE ROOF UNDERLAYMENT ON 1/2" ROOF PLYWOOD 2X4 TREATED LEDGERS, MECHANICALLY FASTEN TO FRAMING 1x6 FIBER CEMENT TRIM ROOF SHEATHING FIBER CEMENT LAP SIDING 2X6 FIBER CEMENT TRIM WITH BEVELED TOP EDGE 1X2 FIBER CEMENT TRIM 1x12 FIBER CEMENT TRIM 1X TREATED WOOD BLOCKING 5/16" FIBER CEMENT PANEL BOARD CL1/2"1'-0 3/4"1:12 CONTINUOUS HOOK STRIP 1/2"1'-1" 1'-8"1'-0" METAL PARAPET COPING WITH DRIP EDGE WOOD BLOCKING SELF ADHERED MEMBRANE FLASHING UNDER ROOFING MEMBRANE AND TO LAP OVER WEATHER BARRIER EXTERIOR SHEATHING 2" RIGID INSULATION 1/4" GAP BETWEEN FLASHING AND SIDING -DO NOT PROVIDE SEALANT SINGLE PLY ROOFING MEMBRANE, EXTEND OVER PARAPET WALL PARAPET FRAMING, RE: STRUCTURAL COVER BOARD 7 1/4" CROWN MOULD 1X2 FIBER CEMENT TRIM 2X4 TREATED FRAMING 1X8 FIBER CEMENT TRIM FIBER CEMENT SOFFIT PANEL 1X4 FIBER CEMENT TRIM 1X12 FIBER CEMENT TRIM ROOF TRUSSES, RE: STRUCTURAL WEATHER BARRIER EXTERIOR SHEATHING 2X TREATED FRAMING METAL FLASHING WITH DRIP EDGE SET IN CONTINUOUS BED OF SEALANT SELF-ADHERED HIGH TEMPERATURE ROOF UNDERLAYMENT ON 1/2" ROOF PLYWOOD 2X4 TREATED LEDGERS, MECHANICALLY FASTEN TO FRAMING 1x6 FIBER CEMENT TRIM ROOF SHEATHING FIBER CEMENT LAP SIDING 1X8 FIBER CEMENT TRIM 1X2 FIBER CEMENT TRIM FIBER CEMENT PANEL.ADD 1X BLOCKING FOR PANEL VENEER 1x12 FIBER CEMENT TRIM 4'-7"WOOD BLOCKING CONTINUOUS HOOK STRIP BLDG B TRUSS BEARING +861' -1 19/32" 1/4" GAP BETWEEN FLASHING AND TRIM -DO NOT PROVIDE SEALANT 7 1/4" CROWN MOULD 1X2 FIBER CEMENT TRIM 2X4 TREATED FRAMING 1X8 FIBER CEMENT TRIM 2X TREATED FRAMING METAL FLASHING WITH DRIP EDGE METAL FLASHING SELF- ADHERED HIGH TEMPERATURE ROOF UNDERLAYMENT ON 1/2" ROOF PLYWOOD 2X4 TREATED LEDGERS, MECHANICALLY FASTEN TO FRAMING 1X12 FIBER CEMENT TRIM O.H. 4" CONTINUOUS HOOK STRIP CL1/2"FIBER CEMENT SOFFIT PANEL 1X4 FIBER CEMENT TRIM 1X TREATED WOOD BLOCKING ROOF TRUSSES, RE: STRUCTURAL WEATHER BARRIER EXTERIOR SHEATHING R-13 BATT INSULATION FIBER CEMENT LAP SIDING 2X6 FIBER CEMENT TRIM WITH BEVELED TOP EDGE 1X2 FIBER CEMENT TRIM 1X TREATED WOOD BLOCKING 5/16" FIBER CEMENT PANEL BOARD 1X2 FIBER CEMENT TRIM METAL FLASHING WITH DRIP EDGE STANDING SEAM METAL ROOF ON UNDERLAYMENT ON 3/4" PLYWOOD 1X8 FIBER CEMENT TRIM 6" DIAM. ROUND GUTTER 2" RIGID INSULATION DOWNSPOUT TO PASS THROUGH CORNICE. REF. 29/A540 FOR PENETRATION FLASHING. 50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Seal Issued / RevisedDate # Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site.8/31/2021 1:30:59 PM C:\Revit Projects\18066-Corner Carmel-CENTRAL-19_smatsumotoBZ9SZ.rvt LRK Project Number: 01.18066.00 A521 PARAPET DETAILS The Corner Carmel, IN VWB DSPThe Corner Carmel, IN •01.18066.001685 E. 116th Street, Carmel, IN SCALE: 3" = 1'-0" 26 LARGE CORNICE -BLDG B SCALE: 3" = 1'-0" 28 SMALL CORNICE -BLDG B SCALE: 3" = 1'-0" 25 LARGE CORNICE AT EAVE -BLDG B 06.16.21 Permit Set A 07.15.21 Addendum A B 08.20.21 IFC Set 11/01/21