HomeMy WebLinkAboutE413S S S S S S S S S S S S S S S S S S S S 1 2 3 4 5 5 5 6 7 8 9 9 9 10 11 13 14 14 14 15 16 17 A3 A3 A3 A1 A1 A1 A1 A4 A4 A1 A1 A1 18 19 B1 CU-3 EF EF A5 A5 9 A1 A5 A2 A2 A2 A2 A2 H D D A B A1 F I H G H A E H5 SEE UNIT B1 FOR CIRCUIT INFORMATION FCU-3 EWH-2 1 2 3 4 5 5 5 6 7 8 9 9 9 10 11 13 14 14 14 15 16 17 A3 A3 A3 A1 A1 A1 A1 A4 A4 A1 A1 A1 18 19 B1 CU-3 EF EF A5 A5 9 A1 ? ? ? A5 A2 A2 A2 A2 A2 H D D A B A1 F I H G H A E H5 SEE UNIT B1 FOR CIRCUIT INFORMATION 1 2 3 4 55 5 6 7 8 9 9 9 10 11 13 14 14 14 15 16 17 A3 A3 A3 A1 A1 A1 A1 A4 A4 A1 A1 A1 18 19 B1 CU-3 EFEF A5 A5 9 A1 ? ? ? A5 A2 A2 A2 A2 A2 H D D A B A1 F I H G H A E A5 SEE UNIT B1 FOR CIRCUIT INFORMATION 3 4 5 5 5 6 7 8 9 9 9 9 10 12 11 13 14 14 14 15 16 17 A3 A3 A3 A1 A1 A1 A1 A1 18 18 19 CU-3 16,18 FCU-3 10,12 EWH-2 9,11 B2 EF A4 A4 A5 A5 1 1 1 1 14 14 13 13 13 3 17,19 21 4 6 1 13 13 15 14 2 14 14 20 20 23 8 8 2 8 8 8 8 8 8 3 8 8 12 23 5 5 23 23 A1 8 A1 8 A5 8 A5 8 A2 2 A2 2 A2 3 A2 3 A5 8 EF 2 A A D D G E H B F H I 13 50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Issued / RevisedDate # Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site. KBSO Project Number: 20070 1344 South Rangeline Road Suite 202 Carmel, IN 46032 317.344.8044 8/20/2021 12:30:22 PM C:\Users\Slove\Documents\20070 The Corner MEP v19_SamuelLove.rvt LRK Project Number: 01.18066.00 E413 ENLARGED ELECTRICAL PLANS The Corner Carmel, IN Checker Author 116th Street & Rangeline Carmel, INThe Corner Carmel, IN •01.18066.00SHEET KEYNOTES 1 NEMA-5 20 RECEPTACLE AND 20 A CIRCUIT (2#12,#12G) FOR MICROWAVE/HOOD.(INSTALL IN LOWER RIGHT CORNER OF UPPER CABINET) 2 NEMA 14-50R RECEPTACLE AND 50A (3#6,10G CU) CIRCUIT FOR RANGE. COORDINATE EXACT REQUIREMENTS WITH OWNER FURNISHED EQUIPMENT. 3 208 V CIRCUIT (2#10G), CONNECTION AND DISCONNECT SWITCH(30A:2P WP) FOR ACCU. SHOWN HERE FOR REFERENCE,ACCU IS LOCATED ON ROOF AND CIRCUIT TO UNIT PANEL. 4 PUSH SWITCH FOR GARBAGE DISPOSER 5 JUNCTION BOX FOR CEILING FAN WITH LIGHT COMBINATION. PROVIDE CEILING FAN SUPPORT AND BLOCKING HER MANUFACTURERS INSTALLATION INSTRUCTIONS. 6 FLUSH MOUNTED LOAD CENTER. PRESERVE FIRE RATING OF WALL. 7 NEMA 5-20R RECEPTACLE AND 20A (2#12,#12G) FOR WASHER. 8 NEMA 14-30R RECEPTACLE AND 20A CIRCUIT (3#10,#10G) FOR DRYER 9 SMOKE DETECTORS WITH SOUNDER BASE CONNECTED TO UNSWITCHED HOT CONDUCTOR IN CIRCUIT. BUILT IN STORES IN ADAPTABLE UNITS. AUDIO/VISUAL HEARING IMPAIRED DEVICES IN ALL HANDICAP UNITS THAT ARE FOR VISUALLY/HEARING IMPAIRED. TYPICAL. 10 SPLIT WIRED DUPLEX RECEPTACLE FOR DISHWASHER. 11 30A,2 POLE,NEMA 1 DISCONNECT SWITCH FOR WATER HEATER,CIRCUIT WITH 2#10,#10G. 12 SWITCH FOR FAN 13 30A,2 POLE,NEMA 1 DISCONNECT SWITCH FOR FOR FCU,CIRCUIT WITH 2#10,#10G. 14 SPLIT WIRED DUPLEX RECEPTACLE.CONTROL UPPER HALF WITH SWITCH NEAR DOOR LOWER HALF UNSWITCHED. 15 INSTALL DUPLEX RECEPTACLE INSIDE HOME NETWORKING ENCLOSURE CABINET. 16 HOME RUN (1) RG -6 COAX CABLE AND ONE(1) CATEGORY 6 VOICE/DATA CABLE FROM TO THE HOME NETWORKING CABINET ENCLOSURE. ALL LINES TO BE CERTIFIED. 17 RUN VOICE/DATA JACK AND ONE(1) VIDEO JACK IN THE VOICE/DATA/VIDEO CABLES AS REQUIRED FROM THE HOME NETWORKING ENCLOSURE CABINET TO THE VOICE/DATA/VIDEO EQUIPMENT CABINET IN THE NEAREST ELECTRICAL ROOM. 18 EXHAUST FAN WIRED ON/OFF SWITCH AT WALL 19 (4) USB CHARGERS IN SINGLE GANG BACKBOX,MOUNTED +44" AFF. GENERAL NOTES A REFER TO SHEET E-000 FOR GENERAL ELECTRICAL NOTES, SYMBOLS AND ABBREVIATIONS. B REFER TO SHEET E-601 FOR LIGHT FIXTURE SCHEDULE. C REFER TO E-600 SERIES SHEETS FOR LOAD CENTER CIRCUIT SCHEDULES FOR EACH DWELLNG UNIT TYPE. D ELECTRICAL LAYOUTS SHOWN SHALL BE TYPICAL FOR EACH RESIDENTIAL UNIT TYPE IDENTIFIED UNLESS OTHERWISE NOTED. E LIGHT FIXTURE LOCATIONS SHOWN SHALL BE SUPERCEDED BY THE ARCHITECTURAL REFLECTED CEILING PLANS. F INSTALL MULTIPLE SWITCHES SHOWN IN A SINGLE LOCATION BEHIND A SINGLE MULTI-GANG SWITCH FACEPLATE. INSTALL A MAXIMUM OF FOUR (4) SWITCHES BEHIND A SINGLE SWITCH FACEPLATE. G CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF MECHANICAL EQUIPMENT WITH THE MECHANICAL CONTRACTOR. EXACT ELECTRICAL REQUIREMENTS SHALL BE FIELD VERIFIED AGAINST THE EQUIPMENT NAME PLATE DATA. THE CONTRACTOR SHALL MAKE APPROPRIATE ADJUSTMENTS OF FEEDER CIRCUIT CONDUCTORS AND OVERCURRENT PROTECTION PER MANUFACTURER. H RECEPTACLES SHOWN AT COUNTERTOPS MARKED ‘AC’ SHALL BE HORIZONTALLY MOUNTED 4” (MEASURED TO THE DEVICE CENTER) ABOVE THE COUNTERTOP OR BACKSPLASH. MAXIMUM HEIGHT +48” TO TOP OF DEVICE. I ALL RECEPTACLES LOCATED IN KITCHENS AND BATHROOMS SHALL BE GFCI TYPE. J LOAD CENTERS FOR EACH DWELLING UNIT SHALL BE RECESSED IN WALL AS INDICATED. LOAD CENTER SHALL NOT BE INSTALLED IN DEMISING WALL. K POWER CONDUCTORS INSTALLED IN EACH DWELLING UNIT SHALL BE COPPER. L IN EACH DWELLING UNIT, INSTALL COMMUNICATIONS CABLING FROM OUTLETS SHOWN BACK TO HOMENETWORKING CABINET. TERMINATE CABLING AT BOTH ENDS. M PROVIDE DUPLEX RECEPTACLE ON DEDICATED CIRCUIT IN HOMENETWORKING CABINET. N ALL SMOKE ALARM DEVICES WITHIN EACH DWELLING UNIT SHALL BE INTERCONNECTED AND ONLY ALARM WITHIN THE DWELLING UNIT THEY RESIDE. O THE BUILDING FIRE ALARM CONTROL PANEL SHALL MONITOR THE STATUS OF EACH SMOKE ALARM UNIT WITHIN EACH DWELLING UNIT. P DWELLING UNIT SMOKE ALARM DEVICES SHALL BE POWERED BY THE BUILDING FIRE ALARM SYSTEM. Q PROVIDE LOW FREQUENCY AUDIBLE DEVICE WITHIN EACH SLEEPING AREA AND LIVING AREA AS INDICATED ON EACH DWELLING UNIT TYPE. AUDIBLE DEVICES SHALL ALARM UPON ACTIVATION OF BUILDING FIRE ALARM SYSTEM AND DWELLING UNIT SMOKE ALARM DEVICES. R DWELLING UNITS NOTED AS ADA ACCESSIBLE SHALL BE EQUIPPED WITH FIRE ALARM VISUAL DEVICES WITHIN BEDROOMS, BATHROOMS AND COMMON LIVING AREAS AS NOTED ON PLANS. S DWELLING UNITS NOTED AS ADA ACCESSIBLE ELECTRICAL PANELS SHALL BE MOUNTED SO AS THE HIGHEST BREAKER IS NO HIGHER THAN 48" ABOVE FINISHED FLOOR. 1/4" = 1'-0" ENLARGED ELECTRICAL PLAN -UNIT B1p 1 1/4" = 1'-0" ENLARGED ELECTRICAL PLAN -UNIT B1q 2 1/4" = 1'-0" ENLARGED ELECTRICAL PLAN -UNIT B1r3 1/4" = 1'-0" ENLARGED ELECTRICAL PLAN -UNIT B24 1 06.16.21 Permit Set 2 08.20.21 IFC Set SWITCHING SCHEDULE TYPE 1ST SWITCH FUNCTION 1ST SWITCH TYPE 2ND SWITCH FUNCTION 2ND SWITCH TYPE 3RD SWITCH FUNCTION 3RD SWITCH TYPE 4TH SWITCH FUNCTION 4TH SWITCH TYPE A BEDROOM "A3" FIXTURE DUAL SLIDE FOR SEPERATE FAN AND LIGHT CONTROL BEDROOM SWITCHED RECEPTACLES SNAP B HALLWAY "A1" FIXTURE SNAP LIVING ROOM "A3" FIXTURE DUAL SLIDE FOR SEPERATE FAN AND LIGHT CONTROL LIVING ROOM SWITCHED RECEPTACLE SNAP C KITCHEN "A1" FIXTURES SNAP D BATHROOM "A1" AND "A2" FIXTURES SNAP BATHROOM EXHAUST SNAP E MECHANICAL ROOM "A5" FIXTURE SNAP F HALLWAY "A1" FIXTURE SNAP G HALLWAY "A1" FIXTURE SNAP KITCHEN "A1" FIXTURE SNAP KITCHEN "A4" FIXTURE SNAP H CLOSET "A5" FIXTURE SNAP I LAUNDRY ROOM "A5" FIXTURE SNAP J KITCHEN "A1" FIXTURES SNAP KITCHEN "A4" FIXTURE SNAP K LIVING ROOM "A3" FIXTURE DUAL SLIDE FOR SEPERATE FAN AND LIGHT CONTROL LIVING ROOM SWITCHED RECEPTACLE SNAP L PORCH LIGHT SNAP 11/01/21