Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
E603b
50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Issued / RevisedDate # Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site. 1344 South Rangeline Road Suite 202 Carmel, IN 46032 317.344.8044 8/20/2021 12:31:36 PM C:\Users\Slove\Documents\20070 The Corner MEP v19_SamuelLove.rvt LRK Project Number: 01.18066.00 E603b ELECTRICAL SCHEDULES The Corner Carmel, IN Checker Author 116th Street & Rangeline Carmel, INThe Corner Carmel, IN •01.18066.00Notes: Total Est. Demand: 115 A Total Conn.: 172 A HVAC - DWELLING UNIT - NONCOINCIDENTAL 2496 VA 0.01% 0 VA Total Est. Demand: 23835 VA DWELLING UNIT 25868 VA 63.19% 16347 VA Total Conn. Load: 35852 VA HVAC 7488 VA 100.00% 7488 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Legend: Total Amps: 168 A 176 A Total Load: 17460 VA 18392 VA 23 1248 VA 24 21 2250 VA 1248 VA 2 20 A CU-2 22 19 EWH-1 30 A 2 2250 VA 1500 VA 20 17 WASHER 20 A 1 1500 VA 1500 VA 2 30 A DRYER 18 15 DISHWASHER 20 A 1 1500 VA 1000 VA 1 20 A REFRIGERATOR 16 13 DISPOSAL 20 A 1 800 VA 4000 VA 14 11 MICROWAVE 20 A 1 1500 VA 4000 VA 2 50 A RANGE 12 9 KITCHEN-RECEPT 20 A 1 540 VA 540 VA 1 20 A KITCHEN-RECEPT 10 7 1440 VA 1 20 A LIVING ROOM/HALLWAY-RECEPT 8 5 DATA 20 A 1 180 VA 3744 VA 6 3 BATHROOM LIGHTING 20 A 1 210 VA 3744 VA 2 40 A FCU-2 4 1 DWELLING UNIT 20 A 1 258 VA 900 VA 1 20 A BEDROOM-RECEPT 2 CKT Circuit Description Trip Poles A B Poles Trip Circuit Description CKT Enclosure: MCB Rating: 125 A Mounting: Wires: 3 Mains Rating: Supply From: Phases: 1 Mains Type: MCB Location: BEDROOM 120 Volts: 120/208 Single A.I.C. Rating: Branch Panel:A4 DEMAND FACTORS AND DIVERSITIES CALCULATED ACCORDING TO NEC 220.82 Notes: Total Est. Demand: 122 A Total Conn.: 186 A Total Est. Demand: 25281 VA HVAC - DWELLING UNIT -... 3744 VA 0.01% 0 VA Total Conn. Load: 38661 VA HVAC 7696 VA 100.00% 7696 VA Load Classification Connected Load Demand Factor Estimated... Panel Totals Total Amps: 188 A 182 A Total Load: 19700 VA 18961 VA 23 BATHROOM LIGHTING 20 A 1 210... 540... 1 20 A RECEPT - KITCHEN 24 21 1500... 1 20 A MICROWAVE 22 19 3848... 4000... 20 17 FCU-3 40 A 2 3848... 4000... 2 50 A RANGE 18 15 1872... 2250... 16 13 CU-3 25 A 2 1872... 2250... 2 30 A EWH-2 14 11 LIVING ROOM/HALLWAY-RECEPT 20 A 1 1440... 1500... 12 9 KITCHEN-RECEPT 20 A 1 540... 1500... 2 30 A DRYER 10 7 REFRIGERATOR 20 A 1 1000... 1080... 1 20 A BEDROOM-RECEPT 8 5 WASHER 20 A 1 1500... 210... 1 20 A BATHROOM LIGHTING 6 3 LIGHTING 20 A 1 321... 900... 1 20 A BEDROOM-RECEPT 4 1 DATA 20 A 1 180... 800... 1 20 A DISPOSAL 2 CKT Circuit Description Trip Poles A B Poles Trip Circuit Description CKT Enclosure: NEMA 1 MCB Rating: 125 A Mounting: RECESSED Wires: 3 Mains Rating: Supply From: METER Phases: 1 Mains Type: MCB Location: MULTIPLE Volts: 120/208 Single A.I.C. Rating: Branch Panel:B5 1 08.20.21 IFC Set 11/01/21