Loading...
HomeMy WebLinkAboutEP121bFFJ J J J J J J J J J SSESCRES CRESCRC CRES S S DCWAP F J J J J J J DHDHF F J J J J S SSSS F CR ESWAP CCCRESCRESES CRCRESC CS S S S J J JCRES S S J SFFCU-4 STORAGE B148 STORAGE B147 ASSIGNABLE GARAGE B107b ASSIGNABLE GARAGE B107c ASSIGNABLE GARAGE B105 ASSIGNABLE GARAGE B103 S1b B106 A1n B102 A2j B104 B1n B108 13 1 3 4 4 4 4 4 4 4 6 6 6 8EF-3 HPB1B-20 HPB1B-20 HPB1B-21 HPB1B-21 HPB1B-22 HPB1B-22 HPB1B-26 HPB1B-27 UH-1 HPB1B-28 HPB1B- 29,31 UH-2 HPB1B-30,32EWH-1HPB1B-33,35HPB1B-34HPB1B-36 HPB1B-37UH-4 HPB1B- 38,40 2 / E405 1 / E410 4 / E404 4 / E412 3 / E401 FCU-5 STORAGE B149 ASSIGNABLE GARAGE B121a ASSIGNABLE GARAGE B121b B2 B115 A1h B110 A1k B114 A2j alt 1 B119 A2j B118 A2h B120 A2h B116 A2h alt 1 B117 B1h B112 4 4 4 4 4 5 HPB1B 7 1 6 6 6 FCU-5 4 EF-1 9 9 10 11 12 12 HPB1A-23HPB1A-24,26 HPB1A-25HPB1A-25 HPB1B -4 HPB1B- 5 HPB1B- 6 HPB1B-6 2 2 HPB1B- 8 HPB1B- 9 HPB1B- 10,12 +60" HPB1B-11 HPB1B -13 2 HPB1B-14HPB1B-15EWH-3 HPB1B- 16,18 HPB1B-17HPB1B-19 HPB1B-23 HPB1B-23 HPB1B-24 HPB1B-24 1 / E408 14 1 / E408 5 / E407 6 / E404 2 / E408 4 / E413 4 / E404 1 / E410 5 / E407 +60" HPB1B-48 USB USB USB HPB1B-49 50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Issued / RevisedDate # Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site. KBSO Project Number: 20070 1344 South Rangeline Road Suite 202 Carmel, IN 46032 317.344.8044 8/20/2021 12:34:26 PM C:\Users\Slove\Documents\20070 The Corner MEP v19_SamuelLove.rvt LRK Project Number: 01.18066.00 EP121b PARTIAL L01 ELECTRICAL PLANS -BLDG B The Corner Carmel, IN Checker Author 116th Street & Rangeline Carmel, INThe Corner Carmel, IN •01.18066.001/8" = 1'-0" PARTIAL BLDG B L01 SE ELECTRICAL PLAN11/8" = 1'-0" PARTIAL BLDG B L01 SW ELECTRICAL PLAN2 GENERAL NOTES A REFER TO SHEET E-000 FOR GENERAL ELECTRICAL NOTES, SYMBOLS AND ABBREVIATIONS. B REFER TO E-600 SERIES SHEETS FOR LOAD CENTER CIRCUIT SCHEDULES FOR EACH DWELLNG UNIT TYPE. C ALL RECEPTACLES SHOWN LOCATED ON BUILDING EXTERIOR OR ROOF SHOULD BE PROVIDED WITH IN-USE WEATHERPROOF ENCLOSURE. D ROOF TOP CONDENSING UNITS SERVING RESIDENT UNITS FED FROM ASSOCIATED APARTMENT LOAD CENTER. SEE ENLARGED UNIT PLANS IN E-400 SERIES DRAWINGS FOR CIRCUIT INFORMATION. E CONDUCTOR SIZES LISTED ARE ACCURATE FOR CIRCUITS UP TO 100' IN LENGTH. FOR CIRCUIT LENGTHS GREATHER THAN 100', UPSIZE CONDUCTORS AS NECESSARY TO LIMIT VOLTAGE DROP TO 3% OR LESS FROM PANEL. F CONTRACTOR TO PROVIDE (2) 3/4" MICRODUCTS AND (1) 3/8" SMOOTHBORE INNER DUCT WITH PULL STRINGS AND BUSHINGS FROM IDF TERMINAL BOARD TO EACH APARTMENT UNIT HOME NETWORK ENCLOSURE. G ALL TV LOCATIONS SHOWN TO RECEIVE (2) RJ45 JACKS WITH CAT 6 CABLING ROUTED FROM NEAREST IDF CLOSET UNLESS NOTED OTHERWISE. H PROVIDE FIRE STOP FOR ALL COMMUNICATION RACEWAYS THAT PENETRATE FIRE WALLS. I ALL COMMUNICATION CABLE TO BE INSTALLED AND TESTED ACCORDING TO BICSI STANDARDS. REPLACE ANY CABLING THAT DOES NOT PASS TESTING PRIOR TO FINAL TERMINATIONS. J ALL FIRE STROBES TO BE 75cd UNLESS NOTED OTHERWISE. K PROVIDE FLOW AND TAMPER SWITCHES FOR ALL FIRE RISERS AND STAND PIPES. COORDINATE LOCATIONS WITH FIRE SUPRESSION SYSTEM DESIGNER. SHEET KEYNOTES 1 PROVIDE 120V, 20A DEDICATED CIRCUIT FOR ELECTRIC UNIT HEATER. 3 PROVIDE 208V, 20A DEDICATED CIRCUIT FOR ELECTRIC UNIT HEATER. 4 PROVIDE CEILING MOUNTED JUNCTION BOX AND 120V, 20A CIRCUIT FOR GARAGE DOOR OPERATOR. 5 PROVIDE 120V, 20A CIRCUIT FOR MAGNETIC DOOR HOLDS. COORDINATE WITH FIRE ALARM SHOP DRAWINGS. 6 PROVIDE 120V CONNECTION TO SECURE DOOR POWER SUPPLY. 7 PROVIDE 120V HARD WIRED CONNECTION RESTROOM EXHAUST FAN. WIRE TO LIGHTING CIRCUIT. ENSURE LIGHTING CONTROL DEVICE IS RATED FOR FAN OPERATION. 8 PROVIDE 120V, CONNECTION TO FRACTIONAL HP EXHAUST FAN. 9 CAMERAS TO BE MOUNTED ON WALL 8' AFF. 10 PROVIDE 120V, 20A DEDICATED CIRCUIT FOR REFRIGERATION. 11 PROVIDE ROUGH-IN FOR EXTERIOR LUXER KIOSK STUBBED OUT FROM SIDEWALK. COORDINATE EXACT LOCATION WITH KIOSK INSTALLER. 12 PROVIDE ROUGH-IN FOR LUXER KIOSK 46" AFF. COORDINATE EXACT LOCATION WITH KIOSK INSTALLER. 13 PROVIDE 208V, 30A DEDICATED CIRCUIT FOR ELECTRIC UNIT HEATER. 14 PROVIDE BATTERY POWERED EMERGENCY INVERTER FOR EGRESS LIGHTING. USE MYERS EMERGENCY POWER SYSTEMS ILLUMINATOR LV-2-R-1-B20. 1 06.16.21 Permit Set 2 07.15.21 Addendum A 3 08.20.21 IFC Set 11/01/21