Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
EP124b
F FSSS S F F S S SSS CORRIDOR-2 B437-2 HPB4B HPB4B- 2HPB4B- 1 HPB4B-1 HPB4B-1HPB4B- 4 HPB4B-6,8 1 CORRIDOR-1 B437-1A1m B402 A1 alt 1 B401 STAIR B2 B442 A2k B404 S1 B403 S1 B405 S1 B406 ELEC. B442a MECH. B440 B1 B407B1m B408 3 1 / E405 3 / E408 1 / E401 3 / E412 3 / E404 2 / E403 1 / E401 1 / E401 1 / E410 5 / E403HPB4B-3HPB4B-3HPB4B-3 HPB4B- 3 HPB4B-3HPB4B-3 HPB4B- 5 FCU-5 HPB4B-7,9 2 A1a B409A1g B410 B1g B412 B1a B411 CORRIDOR B438 A1j B414 B2 A413 A2e B416 A2K B418 B2 A415 A2e alt 1 B417 A2k alt1 B419 STAIR B1 B454 MECH. B453 A2e B420 A2 B421 3 3 / E404 1 / E410 1 / E407 3 / E408 4 / E408 2 / E407 1 / M406 4 / E413 5 / E403 2 / E4101 / E410 1 / E406 1 / E407 50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Issued / RevisedDate # Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site. KBSO Project Number: 20070 1344 South Rangeline Road Suite 202 Carmel, IN 46032 317.344.8044 8/20/2021 12:35:38 PM C:\Users\Slove\Documents\20070 The Corner MEP v19_SamuelLove.rvt LRK Project Number: 01.18066.00 EP124b PARTIAL L04 ELECTRICAL PLANS -BLDG B The Corner Carmel, IN Checker Author 116th Street & Rangeline Carmel, INThe Corner Carmel, IN •01.18066.001/8" = 1'-0" PARTIAL BLDG B L04 SE ELECTRICAL PLAN1 1/8" = 1'-0" PARTIAL BLDG B L04 SW ELECTRICAL PLAN2 GENERAL NOTES A REFER TO SHEET E-000 FOR GENERAL ELECTRICAL NOTES, SYMBOLS AND ABBREVIATIONS. B REFER TO E-600 SERIES SHEETS FOR LOAD CENTER CIRCUIT SCHEDULES FOR EACH DWELLNG UNIT TYPE. C ALL RECEPTACLES SHOWN LOCATED ON BUILDING EXTERIOR OR ROOF SHOULD BE PROVIDED WITH IN-USE WEATHERPROOF ENCLOSURE. D ROOF TOP CONDENSING UNITS SERVING RESIDENT UNITS FED FROM ASSOCIATED APARTMENT LOAD CENTER. SEE ENLARGED UNIT PLANS IN E-400 SERIES DRAWINGS FOR CIRCUIT INFORMATION. E CONDUCTOR SIZES LISTED ARE ACCURATE FOR CIRCUITS UP TO 100' IN LENGTH. FOR CIRCUIT LENGTHS GREATHER THAN 100', UPSIZE CONDUCTORS AS NECESSARY TO LIMIT VOLTAGE DROP TO 3% OR LESS FROM PANEL. F CONTRACTOR TO PROVIDE (2) 3/4" MICRODUCTS AND (1) 3/8" SMOOTHBORE INNER DUCT WITH PULL STRINGS AND BUSHINGS FROM IDF TERMINAL BOARD TO EACH APARTMENT UNIT HOME NETWORK ENCLOSURE. G ALL TV LOCATIONS SHOWN TO RECEIVE (2) RJ45 JACKS WITH CAT 6 CABLING ROUTED FROM NEAREST IDF CLOSET UNLESS NOTED OTHERWISE. H PROVIDE FIRE STOP FOR ALL COMMUNICATION RACEWAYS THAT PENETRATE FIRE WALLS. I ALL COMMUNICATION CABLE TO BE INSTALLED AND TESTED ACCORDING TO BICSI STANDARDS. REPLACE ANY CABLING THAT DOES NOT PASS TESTING PRIOR TO FINAL TERMINATIONS. J ALL FIRE STROBES TO BE 75cd UNLESS NOTED OTHERWISE. K PROVIDE FLOW AND TAMPER SWITCHES FOR ALL FIRE RISERS AND STAND PIPES. COORDINATE LOCATIONS WITH FIRE SUPRESSION SYSTEM DESIGNER. SHEET KEYNOTES 1 PROVIDE NON-FUSED DISCONNECT AND 208V, 1PH, 30A CIRCUIT FOR FAN COIL UNIT. USE (2) #10 AND (1) #10 GND.E 2 PROVIDE NON-FUSED DISCONNECT AND 208V, 1PH, 50A CIRCUIT FOR FAN COIL UNIT. USE (2) #8 AND (1) #10 GND. 3 PROVIDE BATTERY POWERED EMERGENCY INVERTER FOR EGRESS LIGHTING. USE MYERS EMERGENCY POWER SYSTEMS ILLUMINATOR LV-2-R-1-B20. 1 06.16.21 Permit Set 2 08.20.21 IFC Set 11/01/21