Loading...
HomeMy WebLinkAboutES101J JJ JJ J JJ J JJ J JJ J J JJ J J JJJFJ J J S SSS S SSS SS SS SSS MLCRCRMLJ J J MC1 MC2 CT3 MC5 CT2 MC3 MC4 CT1 MCR1 TX1 TX2 TX4 TX3 MCR2 MR1 TO BLD. C MDP TO BLD. B MDP 4 5 6 2 6 6 6 6 1 3 3 6 6 6 6 6 6 1 ES101 2 11 11 11 11 11 11 11 11 11 11 11 11 1111 HA1A-15 HA1A-16 HA1A-17 HPA3A-18 HPA3A-19 HPA3B-27 HPA3B-28 HPB1B-43 HPB1B-44 HPB1A-39 HPB1A-40 HPB1A-41 HPA3B-29 HPA3B-30 12 13 11 11 11 11 11 11 11 11 11 HPA3B-27 HPA3B-27 HPA3B-27 HPA3B-36 HPA3B-36 HPA3B-36 HPA3B-36 HPA3B-36 HPA3B-36 HA1C 7 7 8 9 9 10 L M N 14 HA1B-47 HA1B-47 HA1B -49 50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Issued / RevisedDate # Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site. KBSO Project Number: 20070 1344 South Rangeline Road Suite 202 Carmel, IN 46032 317.344.8044 8/20/2021 12:36:18 PM C:\Users\Slove\Documents\20070 The Corner MEP v19_SamuelLove.rvt LRK Project Number: 01.18066.00 ES101 ELECTRICAL SITE PLAN The Corner Carmel, IN Checker Author 116th Street & Rangeline Carmel, INThe Corner Carmel, IN •01.18066.001" = 30'-0" SITE PLAN1 SHEET KEYNOTES 1 SEE ONE-LINE DIAGRAMS ON E900 SERIES SHEETS FOR ALL SECONDARY CONDUIT AND WIRE SIZES 2 PROVIDE 4" CONDUIT AND PULL STRING FROM RETAIL METER CENTER TO EACH RETAIL UNIT. ROUTE COUNDUIT UNDER PASEO (NOT SHOWN FOR CLARITY). STUB CONDUIT UP 1'-0" ABOVE FFE AND CAP. COORDINATE FINAL STUB-UP LOCATION WITH KITE 3 PROVIDE 4" CONDUIT AND PULL STRING FROM RETAIL METER CENTER TO EACH RESTAURANT RETAIL UNIT. STUB CONDUIT UP 1'-0" ABOVE FFE AND CAP. COORDINATE FINAL STUB-UP LOCATION WITH KITE 4 CONDUIT STUB UP FOR BUILDING A MDP PANEL 5 CONDUIT STUB UP FOR FIRE PUMP. 6 CONDUIT STUB UP FOR RETAIL TENANT 7 PROVIDE 120V CONNECTION TO GATE MAGLOCK. 8 PROVIDE 120V CONNECTION TO GAS FIRE PIT. 9 PROVIDE 120V CONNECTION TO GAS GRILL STATION. 10 PROVIDE 208V, 30A DEDICATED CIRCUIT FOR ELECTRIC UNIT HEATER. 11 PROVIDE 120V CONNECTION TO EXTERIOR LIGHTED SIGNAGE. COORDINATE FINAL ELEVATION WITH ARCHITECT AND CONNECTION REQUIREMENTS WITH THE EXTERIOR SIGNAGE MANUFACTURER PRIOR TO ROUGH-IN. 12 PROVIDE 208V, 1PH, 50A CIRCUIT TO SOLAR DISCONNECT. INSTALL DISCONNECT WITHIN LINE OF SITE OF BUILDING METER CABINET. DISCONNNECT AND DOWNSTREAM FEEDER BY OTHERS. SEE E901g FOR CIRCUIT DETAILS. 13 PROVIIDE U.G. CONDUIT TO SANITARY LIFT STATION. 1/16" = 1'-0" ENLARGED POOL PLAN 2 1 06.16.21 Permit Set 2 07.15.21 Addendum A 3 08.20.21 IFC Set 11/01/21