R 10' - 0 " 1 2 3 TYP. TYP. EF-4 4 CU-2 CU-2 CU-3 CU-3 CU-3 CU-3 CU-1CU-1 CU-1 CU-1 CU-2 CU-2 CU-2 CU-2 CU-2 CU-2 CU-2 CU-2 CU-2 CU-2 CU-2 CU-2 CU-3CU-3 CU-3 CU-3 CU-2 CU-2 CU-2 CU-2 CU-2 CU-2 CU-2 CU-2 CU-3CU-3 CU-3 CU-3 CU-2 CU-2 CU-2 CU-2 CU-3CU-3 CU-3 CU-3 CU-2 CU-2 CU-2 CU-2 CU-2CU-2 CU-2 CU-2 CU-5 CU-5 CU-5 CU-5 CU-3 CU-3 CU-3 CU-3CU-3 CU-3 CU-3 CU-3 B-B1 B-B2 B-BA B-B1B-B2 B-BA 50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Issued / RevisedDate # Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site. KBSO Project Number: 20070 1344 South Rangeline Road Suite 202 Carmel, IN 46032 317.344.8044 8/20/2021 12:38:12 PM C:\Users\Slove\Documents\20070 The Corner MEP v19_SamuelLove.rvt LRK Project Number: 01.18066.00 M125a PARTIAL ROOF MECHANICAL PLAN -BLDG B The Corner Carmel, IN SJO SLL 116th Street & Rangeline Carmel, INThe Corner Carmel, IN •01.18066.00GENERAL NOTES A REFER TO SHEET M-000 FOR GENERAL MECHANICAL NOTES, SYMBOLS AND ABBREVIATIONS. B REFERENCE SHEET M-500 SERIES FOR MECHANICAL DETAILS. C REFERENCE SHEET M-600 SERIES FOR MECHANICAL SCHEDULES. D NOT ALL UNIT PLANS MAY BE APPLICABLE TO THIS BUILDING. E PROVIDE MECHANICAL SYSTEMS IN COMPLIANCE WITH STATE AND LOCAL CODES. F COORDINATE WITH STRUCTURAL AND FRAMING PLANS PRIOR TO COMMENCING WORK. COORDINATE ALL ROUTING WITH ALL TRADES PRIOR TO FABRICATION. G SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS AND TYPES OF RATED CONSTRUCTION TO MAINTAIN CONSTRUCTION RATING. H THERMOSTATS TO BE LOCATED 44-INCHES A.F.F. OR ALIGNED TO ADJACENT LIGHT SWITCHES. I DRYER AND BATHROOM EXHAUST DUCTWORK TO BE MINIMUM 26 GAUGE. J SEAL ALL FLOOR, CEILING, AND WALL PENETRATIONS. USE FIRE CAULK AT RATED ASSMEBLIES AND GENERAL SEALANT ELSEWHERE. WHERE NON-METALLIC COMPONENTS LARGER THAN 4"ø (I.E. PVC OR CONDUIT) PENETRATES RATED ASSEMBLIES, INSTALL INTUMESCENT COLLAR, WHERE DUCTWORK LARGER THAN 4"ø PENETRATES RATED ASSEMBLIES, INSTALL FIRE DAMPER. K SIZE AND INSTALL REFRIGERANT PIPING AND ACCESSORIES PER MANUFACTURER RECOMMENDATIONS. L ALL EXTERIOR VENT CAP AND VENT HOOD COLORS TO BE APPROVED IN SHOP DRAWINGS. M ALL FAN COIL UNITS TO BE MOUNTED TO WALL UNLESS NOTED OTHERWISE. COORDINATE MOUNTING HEIGHT WITH OTHER TRADES AND SPACE. N THE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING A SIGN ATTACHED TO THE DRYER BOX IN EACH APARTMENT. THE TAG SHALL DOCUMENT THE ASSOCIATED INSTALL DRYER VENT AND READ FOLLOWS: CONNECTED VENT DUCT: STRAIGHT DUCT: X-FEET, 90-DEGREE ELBOWS: COUNT = X, 45-DEGREE ELBOWS: COUNT - X. SHEET KEYNOTES 1 DO NOT TERMINATE ANY EXHAUST OR PLAUMBING VENTS WITHIN 10-FEET OF CORRIDOR FRESH AIR INTAKE DUCT. 2 PROVIDE AND INSTALL CARRIER CONDENSING UNIT AS INDICATED. CONDENSING UNIT IS TO BE MOUNTED ATOP A NEOPRENE PAD ON TREATED LUMBER SLEEPERS. 3 PROVIDE AND INSTALL ROOF VAULT FOR REFRIGERATION PIPING LIKE MODEL "AWI-161010" OR EQUAL WITH STANDARD 14" HEIGHT ROOF CURB. 4 TRASH CHUTE VENT WITH BIRDSCREEN TO BE PROVIDED BY TRASH CHUTE MANUFACTURER. 1 06.16.21 Permit Set 2 08.20.21 IFC Set 11/01/21