HomeMy WebLinkAboutP501bBALL VALVE REDUCED PRESSURE BACKFLOW PREVENTER, MAXIMUM MOUNTING HEIGHT OF 5'-0" ABOVE FLOOR. BALL VALVE TO SYSTEM FROM WATER SUPPLY SOURCE AIR GAP DRAIN FUNNEL PIPE DISCHARGE TO FLOOR DRAIN OR MOP SINK TRAP SHALL NOT BE INSTALLED BELOW FLOOR BUT SHALL BE ROUGHED IN NOT LESS THAN 6" AND NOT MORE THAN 18" ABOVE FLOOR. NO STANDPIPE RECEPTOR SHALL EXTEND MORE THAN 30" NOR LESS THEN 18" ABOVE ITS TRAP. 1 1/2" VENT 1/2"CW 1/2"HW SHUTOFF VALVE WITH THREADED HOSE CONNECTION. 2" WASTE P-TRAP WITH UNION CONNECTIONS FLOOR LINE CLOTHES WASHER RECESSED WALL BOX WITH FACE PLATE; EQUAL TO GUY GRAY SERIES RECESSED WALL BOXES. TYP. WASTE STACK TYP. VENT STACK SINK SHUT-OFF VALVE REDUCER GARBAGE DISPOSAL 5/8" DRAIN HOSE 1-1/2" VENT 2" SAN DISHWASHER 1/2" HW CW SUPPLY HW SUPPLY COUNTERTOP INSTALL AS HIGH AS POSSIBLE UNDER COUNTERTOP CODE APPROVED AIR ADMITTANCE VALVE SLOPE RISER PIPE SAME AS SEWER 18"x18"x4" THICK CONCRETE PAD ROUND FLANGED HOUSING W/ HEAVY DUTY CAST IRON COVER LIKE J.R. SMITH 4251 CLEANOUT PLUGFINISH GRADE AT REFRIGERATORS -12" AFF. REFRIGERATOR ICE MAKER RECESSED WALL BOX WITH FACE PLATE; EQUAL TO OATEY SERIES RECESSED WALL BOXES. ANGLE STOP VALVE WITH THREADED CONNECTION FOR ICE MAKER TUBING 1/2"CW FLOOR LINE PIPE DOUBLE SUPPORT NUT LOCKING NUT HANGER ROD HANGER ROD LOCKING NUT SUPPORT NUTCLEVIS HANGER 14 GAUGE ZINC COATED SHEET STEEL SADDLE AT LEAST 12" LONG PIPE INSULATION INSULATION PREFORMED PIPE SUPPORT INSERT, SAME THICKNESS AS INSULATION MANUFACTURED FOR THIS PURPOSE.12"PENETRATION BOOT & FLASHING TO MEMBRANE ROOFING BY ROOFING CONTRACTOR BASED ON CARLISLE U-8-A. REFER TO MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION. PROVIDE STAINLESS STEEL CLAMPING BAND SURE SEAL WATER CUT-OFF MASTIC ROOK DECK -SEE ARCHITECTURAL DRAWINGS FOR CONSTRUCTION.OPENING IN DECK BY PLUMBING CONTRACTOR. SEE DRAWINGS FOR SIZE INCREASER AS REQUIRED PIPE SIZE PER DRAWINGS R HW DOMESTIC TANK TYPE ELEC. WATER HEATER HVAC FURNACE CW HW CWHWCWUNIT MECHANICAL CLOSET TO FIXTURES IN UNIT 3/4"CW 3/4"HW 3/4"CW 3/4"HW 3/4"CW WALL WALL SEE FLOOR PLAN FOR SIZE OF COLD WATER PIPE MAINS CEILING HUB DRAIN FINISH FLOOR METAL DRAIN PAN FULL SIZE DRAIN VALVE FULL SIZE TO HUB DRAIN ASME T&P RELIEF VALVE WATER HAMMER ARRESTOR BALL VALVE (TYP) SHELF. REFER TO MECHANICAL PLANS DIELECTRIC UNION THERMAL EXPANSION TANK CHECK VALVE DRAIN LINE(S) FLOOR 3 X 2 REDUCER 2" MIN. AIR GAP 50 South B.B. King Blvd. Suite 600 Memphis, TN 38103 901.521.1440 Drawing Name: Client: Drawn By: Checked By: Project Name: Issued / RevisedDate # Issues and Revisions ©2020 LRK Inc. Drawings, written material, and design concepts shall not be used or reproduced in whole or part in any form or format without prior written consent of LRK Inc. Do not scale drawings. Use given dimensions only. If not shown, verify correct dimensions with the Architect. Contractor shall check and verify all dimensions and conditions at job site. KBSO Project Number: 20070 1344 South Rangeline Road Suite 202 Carmel, IN 46032 317.344.8044 8/20/2021 12:59:48 PM C:\Users\Slove\Documents\20070 The Corner MEP v19_SamuelLove.rvt LRK Project Number: 01.18066.00 P501b PLUMBING DETAILS The Corner Carmel, IN KC ABT 116th Street & Rangeline Carmel, INThe Corner Carmel, IN •01.18066.00NOT TO SCALE BACKFLOW PREVENTER DETAIL -BLDG B 1 NOT TO SCALE CLOTHES WASHING BOX PIPING DETAIL -BLDG B2 NOT TO SCALE DISHWASHER/ DISPOSAL AND SINK DETAIL -BLDG B3 NOT TO SCALE EXTERIOR CLEANOUT DETAIL -BLDG B4 NOT TO SCALE ICE MAKER RECESSED WALL BOX DETAIL -BLDG B5 NOT TO SCALE PIPE HANGER DETAIL -BLDG B6 NOT TO SCALE VENT THROUGH ROOF DETAIL -BLDG B7 NOT TO SCALE NOTCHES & BOARD HOLES IN WALL STUDS -BLDG B8 NOT TO SCALE DOMESTIC EWH IN UNIT MECH CLOSET DETAIL -BLDG B9 NOT TO SCALE HUB DRAIN DETAIL -BLDG B10 1 06.16.21 Permit Set 2 08.20.21 IFC Set 11/01/21