HomeMy WebLinkAboutElevations & Floor PlansPRELIMINARYNOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTIONSCOTT PEREZINDIANA REGISTERED ARCHITECT AR19500095SHEET NUMBER:JOB NO.DATE:DRAWING TITLE:STAMP:PROJECT DESCRIPTIONDRAWING INDEXCOPYRIGHT 2019 CARSON DESIGN ASSOCIATESKEY PLANISSUE:CARSON DESIGN ASSOCIATES9415 DELEGATES ROWINDIANAPOLIS, IN 46240ARCHITECTURE / DESIGN CONTACTAREA MAP02.18.2022I2140004A000I214000402.18.2022COVER SHEET1077 3RD AVENUE SW, CARMEL, IN 46032FITNESS & WELLNESS CENTERADLS PACKAGEOZWELL02.18.2022PROJECT STATUSSTACY KENNELLY317.843.3770SKENNELLY@CARSONDESIGN.COMSAM HURT317. 636.3941SAM@TEC-MEP.COMTHE ENGINEERING COLLABORATIVE2410 EXECUTIVE DRIVE - SUITE 100INDIANAPOLIS, IN 46241MEP CONSULTANTWESLEY HARRISON317.423.1550WHARRISON@LHB-ENG.COMLYNCH, HARRISON & BRUMLEVE INC.550 VIRGINIA AVEINDIANAPOLIS, IN 46203STRUCTURAL CONSULTANTDAVID COUNSELL317.771.5975DAVID@LSINDY.COMLAND STEWARDS DESIGN GROUP5022 ROCKVILLE RD.INDIANAPOLIS, IN 46224CIVIL CONSULTANTCEMAL OZDEMIR317.679.9592COZDEMIR@OZWELLFITNESS.COMOZWELL1077 3RD AVENUE SWCARMEL, IN 46032OWNERCIHAN OZDEMIR219.766.1011OZDEMIR@DYNADOME.COMDYNADOME RETRACTABLE ENCLOSURES11025 DELAWARE PKWYCROWN POINT, IN 46037DYNADOME RETRACTABLE ENCLOSURES02.18.20221077 3RD AVENUE SW, CARMEL, IN 46032OZWELLFITNESS & WELLNESS CENTERADLS PACKAGETHIS PROJECT CONSISTS OF AN EXISTING BUILDING WHICH IS COMPRISED OF A 2-STORY WAREHOUSE SPACE AND 2-STORY OFFICE BUILDING. THE 2-STORY OFFICE BUILDING SHALL BE DEMOLISHED AND A NEW, 1-STORY ADDITION SHALL BE CONSTRUCTED ALONG THE WEST SIDE OF THE EXISTING WAREHOUSE. THIS WILL BE A NEW A3-OCCUPANCY PHYSICAL FITNESS FACILITY WITH FULL SPRINKLER SYSTEM, NEW HVAC, ELECTRICAL AND ADDITIONAL ELEMENTS. A NEW GLASS AND METAL ENCLOSURE WILL BE CONSTRUCTED IMMEDIATELY ADJACENT TO THE EAST OF THE EXISTING WAREHOUSE.PROJECT LOCATIONAREA OF WORKTRUESHEET NUMBER SHEET NAMEA000 COVER SHEETG1.00 GENERAL NOTESC1.00 DEMOLITION PLANC2.00 SITE PLANC2.01 SITE DETAILSC2.02 SITE DETAILSC3.00 GRADING PLANC4.00 UTILITY PLANC5.00 EROSION CONTROL PLANC5.01 EROSION CONTROL DETAILSL1.00 PLANTING PLANL2.00 PLANTING DETAILSA011 LIFE SAFETY PLANA101 CONSTRUCTION FLOOR PLANA301 EXTERIOR ELEVATIONSA302 EXTERIOR ELEVATIONSA304 EXTERIOR ISOMETRICSA311 EXTERIOR ELEVATIONS - ENLARGEMENTSA312 EXTERIOR ELEVATIONS - EXISTING AND NEWSPC1 SITE LIGHTING PHOTOMETRIC CALCULATIONS
LEVEL 10' -0"ROOF23' -10"LEVEL 1 -ROOF14' -0"T.O.P. -LEVEL 116' -2"B.O.R. CLERESTORY17' -4"1A4111A402T.O.R. CLERESTORY22' -6"2A4113A411ABCDED.5E1E16E13E19E7E2E3E14E13E14E15E15E9E10E9E15E10E9E13E14E13E14E13E5E15E18LEVEL 10' -0"ROOF23' -10"LEVEL 1 -ROOF14' -0"T.O.P. -LEVEL 116' -2"B.O.R. CLERESTORY17' -4"1A401T.O.R. CLERESTORY22' -6"E2E3E4E1E6E57A412E16E2E4E3E2E8E14E10E19E7E13E15E8E10E15E9E9E9E13E14E15E9E15E20E13E9LEVEL 10' -0"ROOF23' -10"LEVEL 1 -ROOF14' -0"T.O.P. -LEVEL 116' -2"B.O.R. CLERESTORY17' -4"1A401T.O.R. CLERESTORY22' -6"E1E2E3E4E1E2E3E7E5E6E4E5E7E13E15E5E13E13E14E14E15E8E10E8E15E10E14E19E187A412E9E9PRELIMINARYNOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTIONSCOTT PEREZINDIANA REGISTERED ARCHITECT AR19500095SHEET NUMBER:JOB NO.DATE:DRAWING TITLE:STAMP:COPYRIGHT 2019 CARSON DESIGN ASSOCIATESISSUE:A301I214000402.18.2022EXTERIOR ELEVATIONS1077 3RD AVENUE SW, CARMEL, IN 46032OZWELLFITNESS & WELLNESS CENTERADLS PACKAGE02.18.2022PROJECT STATUS02.18.20223/16" = 1'-0"1WEST ELEVATION3/16" = 1'-0"2NORTH ELEVATION3/16" = 1'-0"3SOUTH ELEVATIONKEYED NOTES - ELEVATIONSE1 NEW METAL AND GLASS ENCLOSURE SYSTEM (DYNADOME)E2 EXISTING FLUTED CONCRETE BLOCK. BLAST CLEAN AND PROVIDE PRIMER WITH TWO(2) FINISH COATS. TUCKPOINT AND REPAIR BLOCK AS REQUIRED.E3 EXISTING METAL COPING. CLEAN, PRIME AND REPAINT.E4 PROVIDE NEW MATCHING FLUTED CONCRETE MASONRY UNIT INFILL PANELS.E5 NEW HOLLOW METAL DOOR AND FRAME. GROUT FRAME SOLID. FINISH, PAINT ANDPRIME.E6 NEW METAL AND GLASS EGRESS DOOR.E7 HORIZONTAL AND VERTICAL EXPANSION JOINT AT NEW ADDITION.E8 PREFINISHED STANDING SEAM METAL ROOFING SYSTEM.E9 PREFINISHED COMPOSITE METAL WALL PANEL SYSTEM.E10 PREFINISHED COMPOSITE METAL SOFFIT PANELS BY METAL WALL PANELMANUFACTURER.E11 PREFINISHED METAL TRIM SYSTEM AS REQUIRED BY COMPOSITE METAL WALL PANELSYSTEM.E12 PREFINISHED COMPOSITE METAL COPING SYSTEM BY METAL WALL PANELMANUFACTURER.E13 SWISSPEARL FIBER CEMENT EXTERIOR SIDINGE14 NEW 6" METAL COPING SYSTEME15 NEW 2"x6" ALUMINUM STOREFRONT SYSTEM WITH 1" GLAZING.E16 NEW OVERHEAD DOOR SYSTEM WITH TRANSOM, COMPLETE.E17 PREFINISHED METAL SCREEN WALL SYSTEM.E18 NEW CMU WALL TO MATCH EXISTING FLUTED CMU, METAL GATE AND PREFINISHED 6"METAL COPING FOR NITROGEN TANK ENCLOSURE.E19 NEW PREFINISHED METAL COPING SYSTEM FOR EXPANSION JOINT.E20 NEW ALUMINUM FRAMING BRISE SOLEIL SYTEM.E21 NEW CMU WALL TO MATCH EXISTING FLUTED CMU, METAL GATE AND PREFINISHED 6"METAL COPING FOR TRASH ENCLOSURE.E22 NEW TPO ROOFING SYSTEM ON COVER BOARD, TAPERED RIGID INSULATION,SHEATHING AND METAL DECK.
PRELIMINARYNOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTIONSCOTT PEREZINDIANA REGISTERED ARCHITECT AR19500095SHEET NUMBER:JOB NO.DATE:DRAWING TITLE:STAMP:COPYRIGHT 2019 CARSON DESIGN ASSOCIATESISSUE:A304I214000402.18.2022EXTERIOR ISOMETRICS1077 3RD AVENUE SW, CARMEL, IN 46032OZWELLFITNESS & WELLNESS CENTERADLS PACKAGE02.18.2022PROJECT STATUS02.18.20221ISOMETRIC - NW AERIAL2ISOMETRIC - SW AERIAL
PRELIMINARYNOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTIONSCOTT PEREZINDIANA REGISTERED ARCHITECT AR19500095SHEET NUMBER:JOB NO.DATE:DRAWING TITLE:STAMP:COPYRIGHT 2019 CARSON DESIGN ASSOCIATESISSUE:A311I214000402.18.2022EXTERIOR ELEVATIONS -ENLARGEMENTS1077 3RD AVENUE SW, CARMEL, IN 46032OZWELLFITNESS & WELLNESS CENTERADLS PACKAGE02.18.2022PROJECT STATUS02.18.20221/4" = 1'-0"1WEST ELEVATION DETAIL1/4" = 1'-0"4SOUTH ELEVATION DETAIL1/4" = 1'-0"2SOUTH ELEVATION - PARTIAL COLOR1/4" = 1'-0"3WEST ELEVATION - PARTIAL COLOR1/4" = 1'-0"5NORTH ELEVATION COLORNOBLIS AZURITE 422:CARAT SAPPHIRE 7061:NOBLIS CRYSTAL 125:NOBLIS CRYSTAL 122:NOBLIS CRYSTAL 124:EXTERIOR MATERIAL LEGENDCOMPOSITE PANELS -METAL PANELS -METAL ROOF -SWISSPEARL CLADDING CORPCARAT AZURITE 7041:WINDOW/STOREFRONT -METAL DOORS -CENTRIACENTRIATUBELITECURRIESCOPING -CMU -DYNADOME -METALERAPREFINISHED CENTRIA 1" METAL PANEL RAIN SCREEN SYSTEM. SILVER COLOR.PREFINISHED CENTRIA STANDING SEAM METAL ROOF, SOFFIT, AND FASCIA SYSTEM. SILVER COLOR.PREFINISHED TUBELITE BLACK THERMALLY BROKEN STOREFRONT SYSTEM WITH 1" LOW-E, GRAY SOLAR BAN 60 TINT GLAZING.PAINTED CURRIES HEAVY DUTY INSULATED METAL DOORS. FIELD PAINT TO MATCH COMPOSITE CARAT SAPPHIRE 7061.PREFINISHED METALERA METAL COPING SYSTEM TO MATCH COMPOSITE CARAT SAPPHIRE 7061.FLUTED CMU BLOCK (EXISTING AND NEW). FIELD PAINTED TO MATCH COMPOSITE CARAT SAPPHIRE 7061.BLACK ANODIZED ALUMINUM AND INSULATED GLAZING OPERABLE DOME SYSTEM.SIGNAGE -BACKLIT SIGNAGE SYSTEM.DYNADOME RETRACTABLE ENCLOSURE SYSTEMSEXISTING AND NEW
LEVEL 10' -0"ROOF23' -10"LEVEL 1 -ROOF14' -0"T.O.P. -LEVEL 116' -2"LEVEL 10' -0"ROOF23' -10"LEVEL 1 -ROOF14' -0"T.O.P. -LEVEL 116' -2"LEVEL 10' -0"ROOF23' -10"LEVEL 1 -ROOF14' -0"T.O.P. -LEVEL 116' -2"LOCAL ARTIST MURAL LOCATIONCONTENT COORDINATED WITH CITY OF CARMELLEVEL 10' -0"ROOF23' -10"LEVEL 1 -ROOF14' -0"T.O.P. -LEVEL 116' -2"PRELIMINARYNOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTIONSCOTT PEREZINDIANA REGISTERED ARCHITECT AR19500095SHEET NUMBER:JOB NO.DATE:DRAWING TITLE:STAMP:COPYRIGHT 2019 CARSON DESIGN ASSOCIATESISSUE:A312I214000402.18.2022EXTERIOR ELEVATIONS -EXISTING AND NEW1077 3RD AVENUE SW, CARMEL, IN 46032OZWELLFITNESS & WELLNESS CENTERADLS PACKAGE02.18.2022PROJECT STATUS02.18.20221" = 10'-0"1WEST ELEVATION PRESENTATION1" = 10'-0"2EAST ELEVATION PRESENTATION1" = 10'-0"4NORTH ELEVATION PRESENTATION1" = 10'-0"3SOUTH ELEVATION PRESENTATIONEXISITNG PHOTO WEST ELEVATIONEXISITNG PHOTO EAST ELEVATIONEXISITNG PHOTO SOUTH ELEVATIONEXISITNG PHOTO NORTH ELEVATION
E X I TE X I TE X I TE X I TE X I TE X I TE X I TE X I TFECFECFECFECFECOVERALL DIAGONALDISTANCE = 101' -0"ACTUAL TRAVELDISTANCE82' -4"ACTUAL TRAVELDISTANCE87' -9"ACTUAL TRAVELDISTANCE102' -2"ACTUAL TRAVELDISTANCE88' -6"OVERALL DIAGONALDISTANCE = 113' -4"OVERALL DIAGONALDISTANCE = 130' -0"ACTUAL TRAVELDISTANCE67' -4"DYNADOME125WORKOUT122TRAINING121STAFF120SOCIAL HUB110LOUNGE118CHILDCARE101YOGA103CRYO104RED LIGHT105STRETCHING106MEN'S LOCKER111WOMEN'S LOCKER116JANITOR/STORAGE107MECH ROOM107ACARDIO123SPIN124DISTANCE BETWEENEXITS = 97' -11"DISTANCE BETWEENEXITS = 99' -4"DISTANCE BETWEENEXITS = 111' -6"MEN'S TOILET17LAUNDRY108WOMEN'S TOILET114MEN'S SHOWER113WOMEN'S SHOWER115MAKE UP117CHILDCARE RR101ANURSE IV102COFFEE/SMOOTHIE15MECH103ADOME ADDITIONEXISTING BUILDINGNEW 1-STORY ADDITIONFECFECINDICATES AREA NOT IN CONTRACT. REFER TO FLOOR PLANS FOR ADDITIONAL INFORMATION.E X I TEXIT SIGNEMERGENCY WALL PACKPOINT OF EGRESSSEMI-RECESSED FIRE EXTINGUISHER CABINETOVERALL DIAGONAL DISTANCEMAX DEAD END DISTANCEMAX TRAVEL DISTANCECOMMON PATH OF TRAVELDISTANCE BETWEEN EXITS1 HR SEPARATION2 HR SEPARATION1. SEE CONSTRUCTION DRAWING SHEETS AND SPECIFICATIONS FOR FULL EXTENT OF PROJECT SCOPE.CODE - MEANS OF EGRESS WITH SPRINKLER SYSTEMOCCUPANCYMAXIMUM ALLOWABLE TRAVEL DISTANCE*MAXIMUM ALLOWABLE DEAD END PASSAGESMAXIMUM ALLOWABLE COMMON PATH OF TRAVELA-1 - A-5250'-0"20'-0"75'-0"TRUE1/8" = 1'-0"1LIFE SAFETY PLANPRELIMINARYNOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTIONSCOTT PEREZINDIANA REGISTERED ARCHITECT AR19500095SHEET NUMBER:JOB NO.DATE:DRAWING TITLE:STAMP:COPYRIGHT 2019 CARSON DESIGN ASSOCIATESISSUE:A011I214000402.18.2022LIFE SAFETY PLAN1077 3RD AVENUE SW, CARMEL, IN 46032OZWELLFITNESS & WELLNESS CENTERADLS PACKAGE02.18.2022PROJECT STATUS02.18.20221. APPLICABLE CODESCODE - EXIT SEPARATION DISTANCESOVERALL DIAGONALDISTANCEREQUIRED EXITSEPARATIONDISTANCE BETWEEN EXITS130' - 0" 43' - 3 7/8" 111' - 6"101' - 0" 33' - 8" 97' - 11"113' - 4" 37' - 9 3/8" 99' - 4"CODE - TRAVEL DISTANCES PROVIDEDEXIT ROUTEFROM SUITE / ROOMACTUAL TRAVEL DISTANCE PROVIDEDACTUAL DEAD END PROVIDEDACTUAL COMMON PATH OF TRAVEL PROVIDEDASSEMBLY102' - 2"0' - 0"0' - 0"DYNADOME67' - 4"0' - 0"0' - 0"WORKOUT87' - 9"0' - 0"0' - 0"LIFE SAFETY LEGEND0'1/8" = 1'-0"8'4'8'16'CODE - OCCUPANCY CLASSIFICATION & LOADS, PER SPACEFUNCTION OF SPACE AREA FLOOR AREA PER OCCUPANT OCCUPANT LOADAssembly w/out Fixed Seats ( Unconcentrated) 1,796 SF 15 120Business Areas 1,124 SF 100 12Business Areas 1,667 SF 100 17Day Care 767 SF 35 22Exercise Rooms 984 SF 50 20Exercise Rooms 7,700 SF 50 155Locker Rooms 1,790 SF 50 36382BUILDING CODES AND BUILDING INFORMATIONGENERAL NOTES - CODE REVIEW2014 INDIANA BUILDING CODE (2012 INTERNATIONAL BUILDING CODE WITH INDIANA AMENDMENTS)2014 INDIANA FIRE CODE (2012 INTERNATIONAL FIRE CODE WITH INDIANA AMENDMENTS)2013 AMERICANS WITH DISABILITIES ACT ACCESSIBLE GUIDELINES (ADAAG) FOR BUILDINGS ANDFACILITIES2011 AMERICAN NATIONAL STANDARDS INSTITUTE ACCESSIBLE AND USABLE BUILDINGS AND FACILITIESSTANDARD (ANSI A117.1-2009)2009 INDIANA ELECTRICAL CODE (2008 NEC WITH INDIANA AMENDMENTS)2014 INDIANA MECHANICAL CODE (2012 IMC WITH INDIANA AMENDMENTS)2012 INDIANA PLUMBING CODE (2006 IPC WITH INDIANA AMENDMENTS)2010 INDIANA ENERGY CONSERVATION CODE (675 IAC 19-4) CONSISTING OF ASHRAE STANDARD 90.1(2007 WITH INDIANA AMENDMENTS)
SPIN124DYNADOME125CHILDCARE101RED LIGHT105CRYO104YOGA103LOUNGE118CARDIO123STAFF120NURSE IV102MEN'S LOCKER111WOMEN'S LOCKER116STRETCHING106JANITOR/STORAGE107VESTIBULE100CHILDCARE RR101ATRAINING121SOCIAL HUB110LAUNDRY108COFFEE/SMOOTHIE109MECH ROOM107AA3012A3013A3021A3011A3023A3024MEN'S TOILET112WORKOUT122HALL119MAKE UP117MEN'S SHOWER113WOMEN'S SHOWER115WOMEN'S TOILET114100100A101101A102103104108106107107A107B116A116111119120124A124122B125B125A121121B103A37' - 7"12' - 2"36' - 9"6' - 10 3/4"14' - 3 1/2"23' - 7"8' - 2 5/8"4' - 6 1/2"6' - 6"1 1 1 .0 0 0 °14' - 0"9' - 5"HOLD5' - 0"14' - 3 1/2"17' - 2"11' - 8"6 9 .0 0 0 °9' - 6 1/4"10' - 0"32' - 9 1/2"8' - 8 1/8"1' - 0"9' - 10"HOLD5' - 0"26' - 9 5/8"31' - 0 7/8"16' - 1"25' - 4"11' - 1 1/8"12' - 2 3/8"8' - 3"1 1 1 .0 0 0 °4' - 7 13/16"27' - 9"12' - 4"10' - 6"9' - 1"1' - 1"2' - 7"2' - 4"10' - 10 3/4"12' - 6 1/16"13' - 11"9' - 9 1/8"2' - 3 1/2"37' - 9 7/8"1' - 3"18' - 1"30' - 1 7/16"56' - 8 3/16"11' - 8 1/8"103B105111A114C114B114A114112A112121A121C121D12212' - 2"10' - 5"5' - 11 1/4"21' - 8 3/4"6' - 8"4' - 0"25' - 4"26' - 6 3/8"MECH103AHALL106AM3S.2DEXISTING PARTITION TO REMAINEXISTING SHELL OF BUILDING STRUCTUREM3DTYPE OF WALL STUDWALL STUD SIZE / TYPETOP OF WALL CONDITIONS(SEE STANDARD TOP OF WALL CONDITION DETAILS)NEW PARTITION - NON-INSULATEDNEW PARTITION INSULATEDNEW FIRE RATED PARTITION, 1 HOUR FIRE RATEDNEW FIRE RATED PARTITION, 2 HOUR FIRE RATEDCONSTRUCTION KEY NOTE(S)MISCELLANEOUS SPECIALTY ITEM AND/OR EQUIPMENT - REFER TO MISCELLANEOUS SPECIALTIES AND EQUIPMENT SCHEDULEDOOR - REFER TO DOOR SCHEDULEDEMISING PARTITIONCOORDINATE LEVEL OF FINISH OUTSIDE TENANT SPACE WITH OWNER101INDICATES AREA NOT IN CONTRACT. REFER TO FLOOR PLANS FOR ADDITIONAL INFORMATION.1 = 1 3/4" HAT CHANNEL3 = 3 5/8" STUD SIZE6 = 6" STUD SIZE12 = 12" STUD/BLOCK SIZES = SOUND INSULATIONF = FIRE RATED.1 = ONE SIDE GYPSUM.2 = (1) SIDE GYP; (1) SIDE DEN ARMOR.3 = ONE SIDE DEN ARMOR.4 = ONE LAYER DEN ARMOR EACH SIDEM = METAL STUD FRAMINGCM = CONCRETE BLOCK WALLH = HAT CHANNELG = GRIDGI = GRID / INSULATION+6 = +6 ABOVE GRIDD = FRAMED TO DECK ABOVER = FIRE RATEDA. REFER TO GENERAL PROJECT NOTES AND/OR SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS AND INFORMATION PERTAINING TO THE WORK.B. REFER TO TOP OF WALL CONDITION DETAILS FOR ADDITIONAL INFORMATION REGARDING WALL HEIGHTS, TERMINATION AND/OR OTHER REQUIREMENTS.C. CONTRACTOR SHALL FIELD VERIFY DIMENSIONS OF EXISTING BUILDING AREA PRIOR TO COMMENCING WITH THE WORK. DIMENSIONS AND CONDITIONS INDICATED WERE DETERMINED BY VISUAL SURVEY AND/OR INFORMATION FROM EXISTING DRAWINGS. IF DISCREPANCIES ARE DISCOVERED, NOTIFY THE ARCHITECT IN WRITING FOR REVIEW.D. DIMENSIONS ARE FROM THE FACE OF MASONRY WALLS, COLUMN CENTERLINES, FINISH FACE OF EXISTING WALLS, AND/OR STUD FACE OF NEW WALLS, UNLESS NOTED OTHERWISE.E. DIMENSIONS NOTED WITH 'HOLD' ARE TAKEN FROM FACE OF NEW AND/OR EXISTING WALLS U.N.O.F. DIMENSIONS DESIGNATED WITH ‘+/-‘ REQUIRE FIELD VERIFICATION.G. REFERENCE FIRE RATED WALL LOCATIONS (IF REQUIRED) ON LIFE SAFETY PLAN(S). PROVIDE ASSEMBLIES THAT MEET U.L. REQUIREMENTS AS INDCIATED. AT WALLS THAT ARE INDICATED AS FIRE-RATED OR ACOUSTICALLY RATED, PROVIDE ACOUSTICAL AND/OR FIRE-RATED SEALANT AROUND PERIMETER OF WALL.H. SEAL JOINTS AND PENETRATIONS OF FIRE RATED ASSEMBLIES WITH APPROVED U.L. LISTED "F" AND "T" SYSTEMS. PRIOR TO PURCHASE AND INSTALLATION, SUBMIT PRODUCT DATA AND INSTALLATION INFORMATION IN WRITING FOR ARCHITECT'S REVIEW AND COMMENT. LABEL AND IDENTIFY FIRE RATED PARTITIONS FOR FUTURE REFERENCE ON EACH SIDE OF WALL ABOVE CEILING, CONCEALED FROM VIEW. NOTE THE U.L. ASSEMBLY DESIGNATION WITH 6" RED STENCILED LETTERS.I. WALLS BEHIND AND/OR DIRECTLY ADJACENT TO TOILET ROOM FIXTURES SHALL HAVE A SMOOTH, HARD, NON-ABSORBENT SURFACE. WALL PARTITIONS SHALL NOT BE FINISHED WITH GYPSUM BOARD AND/OR EPOXY PAINT.J. SWITCHES, OUTLETS, THERMOSTATS, CLOCKS, SPEAKERS OR OTHER WALL MOUNTED DEVICES OR CONTROLS SHALL BE INSTALLED IN LOCATIONS WHICH ARE UNOBSTRUCTED BY CABINETS, COUNTERS, RACKS, FIXTURES, FURNISHINGS OR EQUIPMENT. ITEMS INTENDED FOR WALL MOUNTING SHALL NOT BE INSTALLED ON, THROUGH OR INTO ANY OTHER EQUIPMENT UNLESS SPECIFICALLY CALLED FOR. VERIFY MOUNTING HEIGHTS AND CLEARANCES WITH RECOGNIZED ACCESSIBILITY REQUIREMENTS.K. WHERE MATERIALS REFERENCED ON DRAWINGS, OR NECESSARY TO COMPLETETHE WORK OF THIS CONTRACT ARE NOT SPECIFIED HEREIN, OBTAIN ACCEPTANCE OF MATERIALS BY ARCHITECT IN WRITING. WHERE MATERIALS ARE INTENDED TO MATCH EXISTING, PROVIDE CLOSEST POSSIBLE MATCH, SUBJECT TO OWNER'S APPROVAL. ITEMS AND WORK ON DRAWINGS ARE NEW UNLESS INDICATED OTHERWISE. WORK WHICH HAS BEEN DAMAGED SHALL BE REPAIRED OR REPLACED. WHERE ITEM CANNOT BE REPAIRED TO A "NEW CONDITION", ORWHERE THE STRUCTURAL INTEGRITY HAS BEEN AFFECTED, ITEM SHALL BE REPLACED.L. AROUND EXPOSED PIPES, CONDUIT OR DUCTS, INSTALL ENCLOSURES OF THE SAME MATERIAL AND FINISH AS ADJACENT WORK, UNLESS NOTED OTHERWISE.M. FIELD CHECK ROUGH AND/OR FINISH DIMENSIONS FOR ACCURATE FITTING OF EQUIPMENT, CABINETS, COUNTERS, FIXTURES AND ACCESSORIES BEFORE FABRICATION. PROVIDE AND INSTALL NECESSARY FILLERS, SCRIBE STRIPS, PANELS, BASES OR TRIM TO COMPLETE AND FINISH INSTALLATIONS.N. REFER TO FINISH PLAN(S) AND INFORMATION FOR ADDITIONAL WALL REQUIREMENTS, FINISHES AND CEILING TYPES.O. PROVIDE AND INSTALL NECESSARY HARDWARE, BRACKETS, BRACING, ANCHORING, INSERTS, BLOCKING, FURRING OR OTHER SUPPLEMENTARY ITEMS NEEDED FOR COMPLETE INSTALLATION OF EQUIPMENT, CABINETS, FIXTURES, AND ACCESSORIES.P. REFER TO FURNITURE AND/OR ELECTRICAL LOCATION PLANS AND DOCUMENTS FOR ADDITIONAL, MISCELLANEOUS SPECIALTIES AND EQUIPMENT ITEMS THAT MAY NOT BE INDICATED ON THIS SHEET.Q. CONTRACTOR SHALL OBTAIN FROM OWNER REQUIREMENTS FOR INSTALLATIONOF OWNER PROVIDED EQUIPMENT INCLUDING ROUGHING DIAGRAMS, INSTALLATION INSTRUCTIONS, ELECTRICAL SCHEMATICS, TEMPLATES, LAYOUTS AND DIMENSIONS AND OTHER INFORMATION NECESSARY FOR A PROPER, WELL COORDINATED INSTALLATION. PRIOR TO ROUGH-IN SERVICES, CONFER WITH OWNER EXACT LOCATION OF ITEMS AND OBTAIN APPROVAL IN WRITING.1/8" = 1'-0"1CONSTRUCTION FLOOR PLANPLAN LEGENDPRELIMINARYNOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTIONSCOTT PEREZINDIANA REGISTERED ARCHITECT AR19500095SHEET NUMBER:JOB NO.DATE:DRAWING TITLE:STAMP:COPYRIGHT 2019 CARSON DESIGN ASSOCIATESISSUE:A101I214000402.18.2022CONSTRUCTION FLOORPLAN1077 3RD AVENUE SW, CARMEL, IN 46032OZWELLFITNESS & WELLNESS CENTERADLS PACKAGE02.18.2022PROJECT STATUS02.18.2022GENERAL NOTES - CONSTRUCTIONTRUE0'1/8" = 1'-0"8'4'8'16'