Loading...
HomeMy WebLinkAboutA1.0 FLOOR PLAN35'-8"36'-0"35'-8" 36'-0" 36'-0" 180'-0"72'-0"EPEP 23'-8"4" 4" 24'-0"4"4"23'-8"16'-9"7'-4"8'-0" 72'-0"48'-0" 42'-0" 18'-0" 24'-0"14'-8"12'-0" 18'-0" 6'-0" 2'-9 3/4" 6'-4 1/2"4'-3"3'-6"3'-6"3'-6"3'-6"8'-6"4'-3"3'-4 1/2"2'-7 3/4"12'-0"10'-3"8'-6"4'-3"10'-0"3'-4 1/2"3'-5"72'-0"12'-0"3'-4 1/4"2'-7 3/4"30'-0"14'-8"1'-4"21'-6 1/2"21'-1 1/2"5'-0" 9'-8 1/2"10'-0 1/2"10'-5"10'-4 1/2" 11'-0"21'-9 1/2"3'-4 1/2" 18'-8 1/2" 28'-0 1/2" 6" 28'-9 1/4" 12'-0"21'-8"20'-5" 10'-4" 21'-4 1/2"W1 W2 W3 D1 D2 D3 1 2 3 21'-9 1/2"5'-0"10'-9 1/2"45 6 7 8 9 P1 3'-4 1/2" 12'-0" NEW FULL HEIGHT NON-LOAD BEARING PARTITION - 5/8" GYP BD ON BOTH SIDES OF 5 1/2" METAL STUDS FRAMED TO UNDERSIDE OF STRUCTURAL DECK, WITH SLIP TRACK TO ALLOW DEFLECTION. PARTITION SCHEDULE NEW PARTIAL HEIGHT NON-LOAD BEARING PARTITION - 5/8" GYP BD ON BOTH SIDES OF 3 1/2" METAL STUDS FRAMED TO 6" ABOVE SCHEDULED CEILING AND BRACED BACK TO STRUCTURE MAX. 4'-0" O.C. NEW NON-LOAD BEARING PARTITION - 5/8" GYP BD ON FURRING CHANNEL OR 2 1/2" METAL STUDS FRAMED TO EXTERIOR PRE-CAST PANEL. EXTEND UP TO 12' AFF. NEW 8" CONCRETE MASONRY UNIT WALL - WITH OR WITHOUT GYPSUM BOARD (GREEN BOARD IN DAMP AREAS), EXTENDS TO SUPPORT STRUCTURAL STEEL ABOVE. DRAWING ISSUE HISTORY ADLS ISSUE: BID / PERMIT ISSUE: COPYRIGHT 2021 09-009-109 FG FG AS NOTED PROJECT NO: DRAWING DATE: DRAWN BY: CHECKED BY: DRAWING SCALE:CARMEL DETAIL CENTER4250 EAST 96th STREETINDIANANPOLIS, INDIANAA u t o m o t i v e G r o u pNADDRESS: ONE OAKBROOK TERRACEOAKBROOK TERRACE, ILLINOIS 60181FRED@NAPLETON.COM | 630.455.2910A1.0 CONSTRUCTION FLOOR PLAN 06-14-21 CONSTRUCTION GENERAL NOTES NOTE: CONTRACTOR TO VERIFY REQUIRED STUD WIDTH AND SIZE FOR FIELD CONFIRMED HEIGHT LIMITATIONS OF PARTITIONS AS INDICATED. CONSTRUCTION KEYNOTES BELANGER AUTOMATED CAR WASH EQUIPMENT - PROVIDED BY OWNER; GC TO COORDINATE INSTALLATION AND UTILITY REQUIREMENTS WITH SUPPLIER AND VENDOR. PROVIDE PHOTOBOOTH WITH CURVED WALLS (60" RADIUS) AND CURVED, CONTINUOUS WALL BASE (24" RADIUS); SMOOTH TRANSITIONS BETWEEN ALL GYPSUM WALL AND BASE TO EPOXY FLOOR COVERING. WET DETAIL BAY DRY DETAIL BAY WITH SHOP-VAC HOOK-UP TO BE COORDINATED WITH ELECTRICAL PLAN OPEN BAY FOR FUTURE USE SERVICE BAY WITH VEHICLE LIFT AND TECH STORAGE CABINETS; COORDINATE ELECTRICAL AND DATA CONNECTIONS PER MEP POWER/DATA PLAN "PDR" BAY - FOR MINOR PAINT AND DENT REPAIR RAPIDWIRE (BY GLOBAL INDUSTRIES OR APPROVED EQUAL) WELDED WIRE CAGE WITH 5' PANELS, 2" POSTS, 4' SWING GATE AND 5' SLIDING GATE FOR SECURE ENCLOSURE FOR EQUIPMENT STORAGE AND PARTS STORAGE AREAS. TECH LOCKER ROOM AND BREAK ROOM, WITH OWNER SUPPLIED LOCKERS AND APPLIANCES; G.C. TO PROVIDE MILLWORK AND COORDINATE APPLIANCE INSTALLATION. PROVIDE LINEAR TROUGH DRAIN THROUGHOUT DETAIL CENTER WITH SLOPE FINISH SLAB TO PROVIDE POSITIVE DRAINAGE AS REQUIRED. 12'-0" WATERPROOF FABRIC CURTAIN ON MOTORIZED TRACK - OUTDOOR GRADE FABRIC, LIGHT GRAY; MOTORIZED CURTAIN TRACK WITH REMOTE CONTROL BUTTON. GFRC (GLASS FIBER REINFORCED CONCRETE) INFILL PANEL WITH FURRING BETWEEN THE SPANDREL GLASS UNIT; FINISHED FLUSHED WITH THE PRE-CAST CONCRETE PANEL INTERIOR SURFACE. FIXED ALUMINUM LADDER TO ROOF ACCESS HATCH AND STORAGE MEZZANINE AREA ABOVE IT ROOM. OWNER PROVIDED CARWASH ASSEMBLY - COORDINATE WITH OWNER'S VENDOR FOR ALL CONNECTIONS AND INSTALLATION SEQUENCING. VERIFY PLUMBING AND POWER REQUIREMENTS WITH VENDOR PRIOR TO CONCRETE FOUNDATION AND SLAB WORK. SEE ACCESSORY SCHEDULE ON SHEET A1.1 FOR MORE INFORMATION. FIXED ALUMINUM LADDER TO ACCESS STORAGE AREA ABOVE IT ROOM. 09-17-21 3 PERMIT UPDATE: 12-02-21 3 12/28/21