HomeMy WebLinkAboutE001 - ELECTRIAL NOTESE001 DOOR ALARM CONTROL PANEL DACP HINGE SIDE PLUNGER SWITCH DC FIRE PROTECTION SYMBOLS FIRE ALARM CONTROL PANEL FACP FFIRE PULL BOX HORN/STROBE ALARM COMBO SSTROBE FSFLOW SWITCH TSPIV TAMPER SWITCH HORN/STROBE ALARM COMBO WEATHER PROOF AHOOD ANSUL SYSTEM CONNECTION SSMOKE DETECTOR DUCT SMOKE DETECTOR S HEAT DETECTOR H SD MAGNETIC LOCK WITH KEY PAD MAGNETIC LOCK WITH CARD READER HS KP CR CARBON MONOXIDE DETECTOR CO ELECTRICAL SPECIFICATIONS ELECTRICAL SPECIFICATIONS ELECTRICAL SPECIFICATIONS 1. BID INSTRUCTIONS: CONTRACTORS SHALL PROVIDE BASE BID IN STRICT ACCORDANCE WITH DESIGN BASIS EQUIPMENT AND MATERIALS. PROJECT DOES ENCOURAGE COMPETITIVE PRICING AND ALLOWS FOR SUBSTITUTIONS OF EQUAL EQUIPMENT AND MATERIALS AGAINST THE BASIS OF DESIGN. SUBSTITUTE ITEMS WILL BE COMPARED AGAINST DESIGN BASIS DURING SUBMITTAL PROCESS. ENGINEER RESERVES THE RIGHT TO REJECT SUBSTITUTIONS FOUND NOT TO BE EQUAL TO ITEMS LISTED IN DESIGN BASIS.. 2. PRIOR TO PROCUREMENT CONTRACTOR SHALL SUBMIT TO ARCHITECT FULL SUBMITTALS FOR ALL ENERGY CONSUMING OR PRODUCING ITEMS AND FOR ALL SWITCH GEAR, LOAD CENTERS AND PANEL BOARDS. SUBMITTALS SHALL BE DELINEATED WITH TAGS INDICATED ON PRINTS, CONTRACTORS NAME AND PROJECT NAME. CLEARLY INDICATE ALL MODEL NUMBERS AND ALL ACCESSORIES AND OPTIONS BEING PROVIDED. SUBMISSIONS SHALL BE IN PDF FORMAT. ALL EQUIPMENT AND ITEMS SHALL BE PER DESIGN BASIS OR APPROVED EQUAL. ENGINEER RESERVES THE RIGHT TO REJECT ANY SUBSTITUTE ITEM FOUND NOT EQUAL TO THE SPECIFIED ITEM AS DESIGNED. 3. CONTRACTOR SHALL FURNISH A TEMPORARY SERVICE FOR THE USE OF ALL TRADES DURING CONSTRUCTION AS REQUIRED BY THE GENERAL CONTRACTOR. REMOVE ALL TEMPORARY EQUIPMENT AS PERMANENT SERVICES BECOME AVAILABLE. 4. THE DRAWINGS IN THIS SECTION ARE DIAGRAMMATIC AND ARE NOT INTENDED TO DEFINE EXACT QUANTITIES, LOCATIONS OR CODIFIED REQUIREMENTS. DRAWINGS SHOW GENERAL INTENT OF SYSTEMS. MODIFICATIONS IN ELECTRICAL SYSTEM ROUTING AND LOCATIONS AS REQUIRED TO MEET THE INTENT, SHALL BE PERFORMED WITHOUT ADDITIONAL COST TO OWNER. SECURE AND PAY FOR ALL REQUIRED PERMITS. 5. THE ELECTRICAL CONTRACTOR IS TO PROVIDE ALL REQUIRED LABOR, MATERIALS, EQUIPMENT, AND CONTRACTOR'S SERVICES NECESSARY TO COMPLETE THE INSTALLATION OF SYSTEMS REQUIRED IN FULL CONFORMITY WITH APPLICABLE CODES AND ORDINANCES. THE FINISHED JOB SHALL BE FUNCTIONAL AND COMPLETE IN EVERY DETAIL INCLUDING ANY AND ALL SUCH ITEMS FOR A COMPLETE SYSTEM. CONTRACTOR SHALL GUARANTEE ALL LABOR AND MATERIALS ENTERING INTO CONTRACT FOR A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE. 6. ALL WORK SHALL IN BE IN FULL ACCORDANCE WITH 2009 INDIANA ELECTRICAL CODE (2008 NFPA 70), 2010 INDIANA ENERGY CODE (ASHRAE 90.1-2007), PERTINENT STATE, COUNTY, CODES AND ORDINANCE AND INDIANA AMENDMENTS. COORDINATE WORK WITH OTHER TRADES. ELECTRICAL CONTRACTOR SHALL BEAR ALL COSTS RESULTING FROM ANY NON COMPLIANCE WITH CODE REQUIREMENTS 7. MATERIALS AND EQUIPMENT SHALL BE NEW UNLESS INDICATED OTHERWISE. MATERIAL SHALL BEAR U.L. LABEL WHERE SUCH STANDARDS HAVE BEEN ESTABLISHED AND LISTED BY U.L. MATERIALS AND EQUIPMENT SHALL CONFORM WITH THE LATEST ISSUES OF APPLICABLE TECHNICAL STANDARDS. 8. THE ELECTRICAL CONTRACTOR IS TO PROVIDE A COMPLETE SYSTEM OF LIGHTING, RECEPTACLES, AND POWER AS REQUIRED. VERIFY ALL VOLTAGES AND PHASE REQUIREMENTS WITH MECHANICAL CONTRACTOR'S EQUIPMENT PRIOR TO PERFORMING ANY WORK. 9. ELECTRICAL CONTRACTOR SHALL VISIT THE SITE AND VERIFY ALL EXISTING CONDITIONS BEFORE SUBMITTING A BID. NO EXTRAS WILL BE ENTERTAINED FOR CONTRACTORS FAILURE TO IDENTIFY EXISTING CONDITIONS AND ADJUST AS REQUIRED TO MEET DESIGN INTENT. 10. ALL CONDUIT COUPLINGS AND CONNECTIONS SHALL BE COMPRESSION TYPE AND MADE TO ENSURE POSITIVE GROUNDING CONTINUITY. MAKE CONNECTIONS TO EQUIPMENT SUBJECT TO VIBRATION WITH 18 INCHES OF FLEXIBLE WATERTIGHT CONDUIT WITH WATERTIGHT FITTINGS. PROVIDE FOR SUPPORT AND SECURING OF ALL CONDUIT AND EQUIPMENT. CONNECTIONS TO LIGHTING FIXTURES SHALL BE MADE WITH SIX (6) FEET OF FLEXIBLE CONDUIT FROM A BOX WITHIN TWO (2) FEET OF THE FIXTURE. SPLICE ALL WIRES ONLY IN ACCESSIBLE BOXES. ALL FIXTURE WHIPS TO BE FLEXIBLE METAL CONDUIT 1/2" MINIMUM SIZE WITH COMPRESSION CONNECTORS WITH INSULATED THROATS. WHIPS SHALL NOT EXCEED 6'. FIXTURE WHIPS TO BE SUPPORTED FROM BUILDING STRUCTURE. WIRING AND RACEWAYS 1. ALL LIGHTING AND BRANCH CIRCUIT WIRING SHALL BE SOLID COPPER MINIMUM SIZE #12 AWG. 600V INSULATION, 75 DEG. C., TYPE THW OR THWN, NOT LESS THAN #12 AWG. ALL WIRE SERVING AS FEEDS TO DISTRIBUTION PANEL BOARDS OR INTEGRAL HORSEPOWER MOTORS SHALL BE EITHER STRANDED COPPER CONDUCTOR OR ASTM B800 ALUMINUM AA-8000 SERIES. THESE SHALL BE SIZED NOT LESS THAN #10 AWG FOR COPPER AND NOT LESS THAN #8 AWG FOR ALUMINUM. EACH WITH MINIMUM 600V THW OR THWN INSULATION, 75 DEG. C. ALL FEEDER SHALL BE SIZED IN ACCORDANCE WITH NEC 310.15. 2. ALL EXPOSED WIRING SHALL BE IN EMT RACEWAY. EXTERIOR WIRING SHALL BE IN CONDUIT. CONCEALED WIRING SHALL BE IN EMT OR METAL CLAD CABLE WHERE ALLOWED BY CODE. 3. ALL LOW VOLTAGE WIRING IN PLENUM RATED CEILINGS OR EXPOSED IN ROOMS SHALL BE PLENUM RATED CABLE. 4. ALL CABLE SHALL BE NEW WIRE OF RECENT MANUFACTURE AND IN ACCORDANCE WITH THE LATEST STANDARDS OF IPCEA AND NEMA AS A MINIMUM. 5. ALL DEVICES AND EQUIPMENT SHALL BE SOLIDLY GROUNDED IN ACCORDANCE WITH NEC REQUIREMENTS. 6. ALL SOLID CONDUCTOR WIRES MAY BE TERMINATED UNDER SCREW HEADS. STRANDED WIRES MAY BE TERMINATED BY USING PUSH-IN CLAMP TYPE CONNECTORS FURNISHED WITH DEVICES OR TERMINATED WITH COMPRESSION TYPE TERMINAL LUGS. SET SCREW TYPE TERMINATIONS ARE NOT PERMITTED. 7. NO MOTORS ARE TO BE SUPPLIED UNDER THIS CONTRACT UNLESS ITEMS REQUIRING A MOTOR ARE FURNISHED BY THIS CONTRACTOR. THE CONTRACTOR SHALL FURNISH ALL STARTERS FOR ALL MOTORS REQUIRING A STARTER. THE CONTRACTOR SHALL CONNECT ALL POWER EQUIPMENT IF & WHERE SHOWN ON PLANS UNLESS OTHER-WISE SPECIFIED & ASSURE OWNER THE MOTORS ARE IN GOOD RUNNING ORDER. 8. E.C. SHALL PROVIDE ALL COMPONENTS NEEDED TO MEET MEANS OF DISCONNECT PER N.E.C. FOR ALL HARD WIRED EQUIPMENT. PANELS AND DISCONNECTS 1. PANELBOARDS SHALL BE A DEAD-LOCK SAFETY TYPE, SURFACE OR RECESSED MOUNTED AS SHOWN, EQUIPPED WITH THERMAL-MAGNETIC MOLDED CASE CIRCUIT BREAKERS WITH FRAME AND TRIP RATINGS AS REQUIRED. TERMINALS FOR FEEDER CONDUCTORS TO THE PANELBOARD MAINS AND NEUTRAL SHALL BE U.L. LISTED AS SUITABLE FOR THE TYPE OF CONDUCTOR SPECIFIED. TERMINALS FOR BRANCH CIRCUIT WIRING, BOTH BREAKER AND NEUTRAL, SHALL BE U.L. LISTED AND CONNECTORS SHALL BE OF THE FULL COMPRESSION TYPE.THE PANELBOARD BUS ASSEMBLY SHALL BE ENCLOSED IN A STEEL CABINET. THE SIZE OF THE WIRING GUTTERS AND GAUGE OF STEEL SHALL BE IN ACCORDANCE WITH NEMA STANDARD PUBLICATION NO. PB-1971 AND U.L. STANDARDS NO. 67 FOR PANELBOARDS. CABINET SHALL BE FABRICATED FROM GALVANIZED STEEL OR EQUIVALENT RUST-RESISTANT STEEL. FRONTS SHALL INCLUDE DOORS AND HAVE FLUSH, BRUSHED STAINLESS STEEL, CYLINDER TUMBLER-TYPE LOCKS WITH CATCHES AND SPRING LOADED DOOR PULLS. THE FLUSH LOCK SHALL NOT PROTRUDE BEYOND THE FRONT DOOR. ALL PANELBOARD LOCKS SHALL BE KEYED ALIKE. FRONTS SHALL HAVE ADJUSTABLE INDICATING TRIP CLAMPS WHICH SHALL BE CONCEALED WHEN THE DOORS ARE CLOSED. DOORS SHALL BE MOUNTED BY COMPLETELY CONCEALED STEEL HINGES. FRONTS SHALL NOT BE REMOVABLE WITH DOOR IN THE LOCATED POSITION. A CIRCUIT DIRECTORY FRAME AND TYPE WRITTEN CARD WITH A CLEAR PLASTIC COVERING SHALL BE PROVIDED ON THE INSIDE OF THE DOOR. THE DIRECTORY CARD SHALL PROVIDE A SPACE AT LEAST 1/4" HIGH X 3" LONG OR EQUIVALENT FOR EACH CIRCUIT. FRONTS SHALL BE OF CODE GAUGE, FULL FINISHED STEEL WITH RUST-INHIBITING PRIMER FACTORY FINISHED ENAMEL PAINT. 2. LOAD CENTERS SHALL BE UL LISTED AND MANUFACTURED IN ACCORDANCE WITH THE LATEST NEMA STANDARDS. CABINETS SHALL USE HINGED STYLE DOORS. MOUNT AT 6'-6" TO TOP OF CABINET. 3. CIRCUIT BREAKERS SHALL BE QUICK-MAKE, QUICK-BREAK, THERMAL-MAGNETIC, TRIP INDICATING AND HAVE COMMON TRIP ON ALL MULTI-POLE BREAKERS. BRANCH CIRCUIT BREAKERS FEEDING CONVENIENCE OUTLETS SHALL HAVE SENSITIVE INSTANTANEOUS TRIP SETTINGS OF NOT MORE THAN 10 TIMES THE TRIP RATING OF BREAKER TO PREVENT REPEATED ARCING SHORTS RESULTING FROM FRAYED APPLIANCE CORDS. CONNECTION TO BUS SHALL BE BOLT ON. 4. CONTRACTOR TO OBTAIN MAXIMUM FAULT CURRENT AVAILABLE FROM THE UTILITY. CALCULATE THE FAULT CURRENT AVAILABLE AT THE PANELS. ALL PANELS/BREAKERS/SWITCHES ARE TO BE BRACED TO EXCEED MAXIMUM AVAILABLE FAULT CURRENT AND CIRCUIT BREAKERS ARE TO BE CAPABLE OF INTERRUPTING FAULT CURRENT. MANUFACTURER SHALL PROVIDE ALL REQUIRED FAULT CURRENT AND ARC-FLASH LABELING PER 110.16 AND 110.24. 5. MAXIMUM LOADING OF 20 AMP CIRCUITS SHALL NOT EXCEED 1750 WATTS. VOLTAGE DROP OF BRANCH CIRCUITS SHALL NOT EXCEED 3% AND FEEDER CIRCUITS SHALL NOT EXCEED 2%. SEAL ALL PENETRATIONS THROUGH WALLS, CEILINGS AND FLOORS AIR AND WATER TIGHT. FIRE STOP WHERE REQUIRED. 6. CONTRACTOR SHALL PROVIDE ENGRAVED BAKELITE NAMEPLATES FOR ALL ELECTRICAL PANELS AS REQUIRED BY NEC 408.4(B) AND SHALL LABEL ALL DISCONNECTS, TRANSFORMERS AND MOTORS OVER 1 HP. FURNISH TYPEWRITTEN PANEL DIRECTORIES TO IDENTIFY ALL ELECTRICAL CIRCUITS BOTH NEW AND EXISTING. 7. DISCONNECT SWITCHES SHALL BE GENERAL DUTY, NEMA TYPE 1 FOR INDOOR SERVICE AND NEMA TYPE 3R FOR OUTDOOR SERVICE, SUITABLE FOR PADLOCKING, NUMBER OF POLES, RATINGS, FUSES (IF REQUIRED) SHALL BE AS INDICATED ON THE DRAWINGS. DEVICES 1. VERIFY EXACT LOCATION, COLOR AND HEIGHTS OF ALL OUTLETS, RECEPTACLES, LIGHT FIXTURES AND EQUIPMENT WITH OWNER'S REPRESENTATIVE PRIOR TO START OF WORK. FURNISH GENERAL SERVICE DUPLEX'S, 15 AMP SWITCHES, 15/20 AMP GFICS, HEAVY DUTY DISCONNECTS, HVAC SSU SWITCHES, PANEL BOARDS, LOAD CENTERS, DISTRIBUTION PANELS ETC. AS REQUIRED. 2. CONVENIENCE RECEPTACLES SHALL BE MOUNTED 18" ABOVE FINISHED FLOOR (A.F.F.) TO BOTTOM UNLESS NOTED OTHERWISE, SWITCHES AND PUSHBUTTONS SHALL BE 42" A.F.F. TO BOTTOM UNLESS SPECIFIED OTHERWISE ON THE DRAWINGS. 3. PRIOR TO ROUGH-IN E.C. SHALL VERIFY FINAL LOCATIONS AND COLORS OF ALL DEVICES WITH OWNER. 4. INSTALL ALL DEVICES PARALLEL AND PERPENDICULAR TO ADJACENT WALL AND CEILING, FLUSH WITH SURROUNDING SURFACES AND FREE FROM ALL OBSTRUCTIONS. REWORKING OF EQUIPMENT INSTALLED IMPROPERLY SHALL BE AT THE CONTRACTOR'S EXPENSE. 5. SWITCHES, BOXES, ETC., SHALL BE NEMA TYPE 1 CONSTRUCTION FOR INDOOR APPLICATIONS AND NEMA TYPE 3R CONSTRUCTION FOR OUTDOOR APPLICATIONS. 6. SWITCHES SHALL MEET NEMA STANDARDS, COLOR SHALL BE BY ARCHITECT. SWITCHES SHALL BE EQUAL TO HUBBELL COMMERCIAL SPECIFICATION GRADE 20/15 AMPERES, SINGLE POLE, 125/277V. MULTI-POLE OR SPECIAL SWITCHING SHALL BE AS NOTED ON THE DRAWINGS. 7. RECEPTACLES SHALL BE 125 VOLT, 15/20 AMPERES, DUPLEX, GROUNDED HUBBELL COMMERCIAL SPECIFICATION GRADE. SPECIAL RECEPTACLES SHALL BE AS NOTED ON THE DRAWINGS. 8. MATCHING COVER PLATES SHALL BE PROVIDED FOR ALL RECEPTACLES AND SWITCHES. LIGHTING FIXTURES: 1. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING FIXTURES- MODEL NUMBERS, QUANTITY AND DISTANCE BETWEEN LIGHTING FIXTURE PER FLOOR PLANS. 2. PRIOR TO ROUGH-IN E.C. SHALL VERIFY FIXTURE QUANTITY, MODELS, STYLE, TRIM, LENS, ETC. WITH OWNER FOR ALL FIXTURES. 3. PROVIDE LIGHTING FIXTURES COMPLETE WITH, BUT NOT NECESSARILY LIMITED TO, HOUSINGS, LAMPS, LAMP HOLDERS, REFLECTORS, BALLASTS, STARTERS AND WIRING. 4. INSTALL LIGHTING FIXTURES AT LOCATIONS AND HEIGHTS AS INDICATED, IN ACCORDANCE WITH FIXTURE MANUFACTURER'S WRITTEN INSTRUCTIONS, APPLICABLE REQUIREMENTS OF NEC, NECA'S "STANDARD OF INSTALLATION", NEMA STANDARDS, AND WITH RECOGNIZED INDUSTRY PRACTICES TO ENSURE THAT LIGHTING FIXTURES FULFILL REQUIREMENTS. 5. COORDINATE WITH OTHER ELECTRICAL WORK AS APPROPRIATE TO PROPERLY INTERFACE INSTALLATION OF INTERIOR LIGHTING FIXTURES WITH OTHER WORK. 6. E.C. TO FASTEN FIXTURES SECURELY DIRECTLY TO BUILDING STRUCTURAL SYSTEM. LIGHT TROFFERS SHALL BE SUPPORTED AT EACH CORNER OF FIXTURE BY WIRES OF SAME GAUGE AS HANGER WIRE FOR CEILING GRID. ATTACH EARTHQUAKE CLIPS TO GRID AS RECOMMENDED BY LIGHT MANUFACTURER. USE SCREWS IF REQUIRED BY MANUFACTURER. ATTACH THE WIRE TO THE STRUCTURE ABOVE. LIGHTS SHALL NOT BE SUPPORTED IN ANYWAY BY LAY-IN CEILING. 7. FIXTURE LOCATIONS SHALL BE AT APPROXIMATE LOCATIONS AS SHOWN ON THE DRAWINGS FREE FROM ALL OBSTRUCTIONS. CLEAN ALL LIGHTING EQUIPMENT AFTER LIGHTING INSTALLATION AND GENERAL CONSTRUCTION IS COMPLETE. REPAIR ANY FIXTURES DAMAGED DURING CONSTRUCTIONS. 8. PROVIDE NECESSARY MOUNTING FRAMES, SUPPORTS AND RELATED ITEMS REQUIRED TO PROPERLY INSTALL FIXTURES. SUPPORT FIXTURES INDEPENDENTLY OF PIPING AND DUCTWORK. MAKE MODIFICATIONS TO THE STRUCTURE AS REQUIRED TO INSTALL FIXTURES. ANY MODIFICATIONS TO THE STRUCTURE SHALL NOT IMPAIR THE STRUCTURAL INTEGRITY OF THE BUILDING. LOW VOLTAGE 1. ALL LOW VOLTAGE CABLE WHERE CONCEALED IN CONSTRUCTION OR IN EXPOSED OPEN AREAS SHALL BE RUN IN MINIMUM 3/4" EMT CONDUIT. CONTRACTOR SHALL INSTALL 3/4" CONDUIT (MINIMUM) FROM EACH LOW VOLTAGE ROUGH-IN LOCATION TO ACCESSIBLE CEILING SPACE, LOW VOLTAGE WIRE TRAY OR HANGERS AND THEN TO MDF, HEAD-IN, PBX PUNCH DOWN, CONTROLLER ETC. 2. E.C. SHALL COORDINATE WITH LOCAL PHONE AND CABLE PROVIDER AS CHOSEN BY OWNER AND PROVIDE RACEWAYS FOR BRINGING IN SERVICES AS REQUIRED. 3. ALL LOW VOLTAGE CABLE SHALL BE PLENUM RATED IN PLENUMS. 4. ALL DATA CABLE SHALL BE CAT 6 UNLESS OTHER WISE NOTED. TERMINATE, LABEL AND TEST ALL WIRING. 5. ALL TV CABLE SHALL BE HIGH DEFINITION COAX RG6 OR AS REQUIRED BY PROVIDER, VERIFY PRIOR TO ROUGH IN. FIRE STOPPING. 1. FIRE STOPPING SYSTEMS SHALL BE IN FULL COMPLIANCE WITH SECTIONS 714 OF THE IBC AND NFPA 221. 2. CONTRACTOR SHALL MAKE REFERENCE TO ARCHITECTURAL PLANS AND PROVIDE ALL REQUIRED FIRE STOPPING. 3. CONTRACTOR SHALL PROVIDE AHJ WITH FULL SUBMITTAL INDICATING METHODS OF CONSTRUCTION AND UL LISTINGS FOR EACH PENETRATION SYSTEM USED. 4. PENETRATIONS OF FIRE-RESISTANCE-RATED WALLS OR FLOOR CEILING ASSEMBLIES BY ELECTRICAL DEVICES, RACEWAYS OR PANELS, ETC. SHALL COMPLY WITH SECTIONS 713.2 THROUGH 713.3.3 OF THE IBC. 5. ACCESS DOORS REQUIRED IN CEILINGS OF FIRE-RESISTANCE-RATED FLOOR/CEILING AND ROOF/CEILING ASSEMBLIES SHALL BE TESTED IN ACCORDANCE WITH ASTM E 119 OR UL 263 AS HORIZONTAL ASSEMBLIES AND LABELED BY AN APPROVED AGENCY FOR SUCH PURPOSE. CLOSE OUT 1. PROVIDE MANUFACTURERS OPERATION AND MAINTENANCE MANUALS AND PROVIDE AS BUILT DRAWINGS. PROVIDE (1) TRAINING SESSION TO OWNER SELECTED PERSONNEL AS REQUESTED AND PROVIDE WARRANTY INFORMATION FOR ALL MANUFACTURERS WARRANTED EQUIPMENT AMPS MECHANICAL CONTRACTOR ELECTRICAL ABBREVIATIONS MANUFACTURER MOUNTING HEIGHT MFR MH MINIMUM MOTOR OPERATED DAMPER MLO MIN MOD MOCP MOUNTED NOT IN CONTRACT PLUMBING CONTRACTOR ON CENTER NOT TO SCALE MTD NIC PC NTS OC COMPANYCO RUNNING LOAD AMPSRLA ELECTRIC CONTRACTOR DOWN DRAWING(S) ELECTRICAL DISTRIBUTION CENTER EQUIPMENT EC DN DWG(S) EQUIP EDC EWC ETR FULL LOAD AMPS MAXIMUM FLA MAX MAIN BREAKERMB MC CONTRACTORCONTR EXISTING TO REMAIN ELECTRIC WATER COOLER MIMIMUM CIRCUIT AMPSMCA MAXIMUM OVER CURRENT PROTECTION MAIN LUG ONLY EMERGENCYEM POUNDS PER SQUARE INCHPSI REVOLUTIONS PER MINUTERPM HORSE POWERHP GENERAL CONTRACTORGC ABOVE FINISHED FLOORAFF EX EXISTING FLOW SWITCHFS A VOLTSV UNLESS OTHERWISE NOTEDUON LIGHTING PANELBOARD SCHEDULE ABBREVIATIONS POWER NON-SEASONALPN MOTOR SUMMER MOTOR NON-SEASONAL MOTOR NON-SEASONAL INTERMITTENT MOTOR WINTER MS MN MNI MW POWER WINTERPW KITCHENKT RECEPTACLER L ELECTRICAL SYMBOLS SPECIAL EQUIPMENT COORDINATE W/SUPPLIER JUNCTION BOX DISCONNECT OUTLET - 4 WAY MOTOR OUTLET - GROUND FAULT INTERRUPT OUTLET - DUPLEX RECESSED DOWN LIGHT LIGHT FIXTURE - ON NIGHT LIGHT CIRCUIT LAYIN TROFFER FIXTURE SUSPENDED LAYIN EXIT SIGNAGE SURFACE MOUNTED STRIP LIGHT SUSPENDED STRIP LIGHT LOW VOLTAGE TWO LINE LOW VOLTAGE ONE LINE ANALOG PHONE LINE WIRELESS ACCESS POINT OUTLET - 220V EXIT SIGNAGE WITH EMERGENCY HEADS LIGHT FIXTURE - WALL SCONCE LIGHT FIXTURE - PENDANT SURFACE MOUNTED LAYIN J FLRFLOOR OUTLET WITH POWER, DATA AND PHONE D 3 SWITCH SWITCH WITH DIMMER SWITCH - 3 WAY OSSWITCH WITH OCCUPANCY SENSOR CEILING MOUNTED OCCUPANCY SENSOR 4SWITCH - 4 WAY OUTLET - GROUND FAULT INTERRUPT WEATHERPROOF WP LOW VOLTAGE # LINES # PUSH BUTTON BUZZER B TIME CLOCK TC PHOTO CELL P POWER POLE PANEL DESIGATION X: XX,XX,XX CIRCUIT BREAKER NUMBERS WAP EMERGENCY LIGHTING UNIT EMERGENCY EXIT EGRESS LIGHT LIGHT FIXTURE - TRACK LIGHT FIXTURE - UNDER COUNTER LIGHT FIXTURE - RECESSED DOWN LIGHT LIGHT FIXTURE - VANITY LIGHT OUTLET - DUPLEX WITH USB J PP OS HS WP ELECTRICAL ABBREVIATIONS, SYMBOLS, & SPECIFICATIONS 1. A SPRINKLER MONITORING FIRE ALARM SYSTEM THAT ACTIVATES THE OCCUPANT NOTIFICATION SYSTEM SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH SECTION 907 OF THE IBC, NFPA 72 AND THE LOCAL FIRE DEPARTMENT. 2. THE FINAL DESIGN FOR THE FIRE ALARM SYSTEM SHALL BE BY A LICENSED FIRE PROTECTION CONTRACTOR WITH A MINIMUM OF 5 YEARS EXPERIENCE. THE SYSTEM SHALL BE FULLY ADDRESSABLE. FIRE ALARM DEVICES ON THE PLANS ARE FOR INTENT ONLY. FINAL DESIGN SHALL BE BY MINIMUM NICET III LICENSED DESIGNER AND SHALL BE SUBMITTED AND APPROVED BY ALL AUTHORITIES HAVING JURISDICTION. REGARDLESS OF WHAT IS INDICATED ON THESE INTENT PLANS CONTRACTOR SHALL PROVIDE ALL REQUIRED DEVICES NEEDED FOR THE APPROVED SYSTEM AT NO ADDITIONAL COST TO THE OWNER. 3. FIRE ALARM CONTRACTOR SHALL SUBMIT THEIR PLANS FOR REVIEW AND APPROVAL BY AUTHORITY(S) HAVING JURISDICTION AND SHALL BE RESPONSIBLE FOR OBTAINING ALL REQUIRED APPROVALS AND PERMITS AND FOR PASSING ALL REQUIRED INSPECTIONS. 4. GENERAL SPECIFICATIONS INCLUDE BUT ARE NOT LIMITED TO THE FOLLOWING: a. SYSTEM SHALL BE EQUIPPED WITH AUTOMATIC EMERGENCY POWER WITH A MINIMUM 24 HOUR SUPPLY. b. DETECTORS SHALL INCLUDE SMOKE DETECTORS (AREA AND DUCT) AND HEAT DETECTORS AS REQUIRED. c. CENTRAL ALARM NOTIFICATION DEVICES ARE REQUIRED IN ALL APARTMENTS WITH LOW FREQUENCY (520 HZ) AUDIBLE NOTIFICATION IN ALL SLEEPING ROOMS. ALL DWELLING AND SLEEPING UNIT NOTIFICATION DEVICES SHALL HAVE THE CAPABILITY TO SUPPORT VISIBLE ALARM NOTIFICATION. ALL ADA UNITS ARE REQUIRED TO HAVE BOTH VISUAL AND AUDIBLE NOTIFICATION. d. POWER TO FIRE ALARM CONTROL PANEL SHALL BE PROVIDED WITH CIRCUIT BREAKER LOCK PER NFPA 72-13, SECTION 10.6.5.4 AND MARKED AS RED. FIRE ALARM SPECIFICATIONS 220 LOW VOLTAGE DIMMING SYSTEMLV DRAWING ISSUE HISTORY ADLS ISSUE: CONSTR ISSUE: COPYRIGHT 2021 210422 JP JP AS NOTED PROJECT NO: DRAWING DATE: DRAWN BY: CHECKED BY: DRAWING SCALE: CARMEL DETAIL CENTER4250 E 96th STREETINDIANAPOLIS, INDIANAA u t o m o t i v e G r o u pN BID / PERMIT ISSUE: MEP Consulting Engineers262 Tradewinds DriveSanta Rosa BeachFlorida 32459317.506.8151dave@gnaengineering.comGOODERUM & ASSOCIATES ENGINEERINGP:E:874 Cheltenham DriveAvon IN, 46123South OfficeNorth Office 11-10-21 11-10-21JEFFREY M . PE R KEY 11/10/2021 CANT AROUND TOP 1" (8) #4 REBAR VERTICALY WITH #4 REBAR SPIRALED AT 6" O.C. AND (3) LAYERS OF #4 REBAR AT TOP AND BOTTOM OF BASE SPACED AT 2" O.C. MAINTAIN MINIMUM OF 3" FROM REBAR TO EDGE OF CONCRETE. ANCHOR BOLTS HAND HOLE 1. POLE SHALL BE CAPABLE OF WITH STANDING 130 MPH WIND GUSTS 2. CONCRETE SHALL BE MINIMUM 3000 PSI 3. MATCH ANCHOR BOLT PATTERN TO POLE MANUFACTURERS BASE PLATE #6 COPPER GROUND WIRE BONDED TO POLE. 5/8"X10' GROUND ROD WITH EXOTHERMIC CONNECTION TO #6 GROUNDING CONDUCTOR. NOTES 60" GRADE 3/4" PVC CONDUIT TO POLE GROUND. 24" 1 NOT TO SCALE LIGHT POLE DETAIL 36" In All areas LIGHT POLE (LENGTH AS REQUIRED TO ACCOMMODATE MOUNTING HEIGHT INDICATED ON ELECTRICAL SITE PLAN. 12/28/21