Loading...
HomeMy WebLinkAboutE002 - ELECTRICAL SCHEDULES, DIAGRAMSE002 ELECTRICAL DETAILS, DIAGRAMS, & SCHEDULES DRAWING ISSUE HISTORY ADLS ISSUE: CONSTR ISSUE: COPYRIGHT 2021 210422 JP JP AS NOTED PROJECT NO: DRAWING DATE: DRAWN BY: CHECKED BY: DRAWING SCALE: CARMEL DETAIL CENTER4250 E 96th STREETINDIANAPOLIS, INDIANAA u t o m o t i v e G r o u pN BID / PERMIT ISSUE: MEP Consulting Engineers262 Tradewinds DriveSanta Rosa BeachFlorida 32459317.506.8151dave@gnaengineering.comGOODERUM & ASSOCIATES ENGINEERINGP:E:874 Cheltenham DriveAvon IN, 46123South OfficeNorth Office 11-10-21 11-10-21JEFFREY M . PE R KEY 11/10/2021 INTERIOR LIGHTING FIXTURE SCHEDULE F1 TYPE DESCRIPTION MANUFACTURER MODEL FINISH DL150931 - 4' LED STRIP WITH CHAIN KIT F2 OWNER SUPPLIED / CONTRACTOR INSTALLED BLACK BLACK F3 F4 F5 F6 DL135726 - 4' LED HIGH BAY WITH CABLE KIT DL150936 - 2X2 LED PANEL DL150940 - LED DIFFUSE LIGHT BOX BLACK BLACK BLACK REFER TO CBMC DRAWING / SCHEDULE FOR DETAILS REFER TO CBMC DRAWING / SCHEDULE FOR DETAILS REFER TO CBMC DRAWING / SCHEDULE FOR DETAILS REFER TO CBMC DRAWING / SCHEDULE FOR DETAILS NEEWER PHOTOGRAPHY LED LIGHTING KIT OWNER SUPPLIED / CONTRACTOR INSTALLED OWNER SUPPLIED / CONTRACTOR INSTALLED OWNER SUPPLIED / CONTRACTOR INSTALLED OWNER SUPPLIED / CONTRACTOR INSTALLED DL130643 - 4' VAPOR LIGHT - WALL MOUNT NOT USED PRIMARY CONDUITS UTILITY TRANSFORMER M A PANEL UTILITY METER TRANSFORMER T1 112.5 KVA, 480-120/208V 3Ø-4W T GROUND HA PANEL PER NEC 3#3/0 A0L, #4G AL, GROUND PER NEC 4#500 MCM AL, #2G AL, 3-1/2"C 2"C (2) 3-1/2"C, 4#500 MCM AL EA., #2/0G AL EA. 1 NOT TO SCALE ELECTRICAL RISER DIAGRAM HB PANEL JUNCTION BOX @ 4" A.F.F. (2) 18 GA. WIRES BY E.C. JUNCTION BOX @ 24" A.F.F. (2) 18 GA. WIRES BY E.C. JUNCTION BOX @ 4" A.F.F. (2) 18 GA. WIRES BY E.C. JUNCTION BOX @ 24" A.F.F. (2) 18 GA. WIRES BY E.C. PUSH BUTTON STATION BY OHD, INSTALLED BY E.C. (4) 18 GA WIRES BY THE E.C. TOTAL OF (10) 18 GA. WIRES ON THE SIDE WITH THE PUSH BUTTON. TOTAL OF (4) 18 GA. WIRES ON THE SIDE WITHOUT THE PUSH BUTTON. E.C TO RUN ALL CONDUIT & WIRES TO THE OPERATOR LOCATION. DETAIL NOTES: 1. ALL WIRES, CONDUIT, & J-BOXES BY THE E.C. LINE VOLTAGE WIRES, CONDUIT, & CONNECTIONS BY THE E.C. 2. LOW VOLTAGE CONNECTIONS & SETUP FOR THE UP/DOWN LIMITS TO BY THE OVERHEAD DOOR VENDOR. 3. PHOTOCELL @ 4" A.F.F. ARE TO PROTECT AGAINST HUMAN ENTRAPMENT PER UL-325 CODE. 4. PHOTOCELLS @ 30" ARE TO PROTECT VEHICLES. (INSIDE LOOKING OUT) FINISHED FLOOR 10" +/-10" +/- 3 SCALE: NO SCALE MOTORIZED OVERHEAD DOOR DETAIL BUILDING STEEL NEC(250-52(A)(2) BUILDING WATER SERVICE (METALLIC) NEC 250-52(A)(1) BUILDING FOUNDATION STEEL REBARS NEC 250-52(A)(3) INCOMING ELECTRICAL SERVICE NO GROUND CONDUCTOR CONSULT LOCAL UTILITY MAIN BONDING JUMPER, PER NEC 250-28 (d) OR INSTALLED AT FACTORY BONDING BUSHING IF METTALIC CONDUIT (TYP.) NEUTRAL BUS EQUIP. GRND. BUS SERVICE EQUIPMENT ENCLOSURE NEC 250-66 NEC 250-66 NEC 250-66(b) BRANCH PANEL NEUTRAL EQUIP. GRND. BUS EQUIPMENT GROUNDING CONDUCTOR NEC 250-122 TABLE BONDING JUMPER IF METTALIC CONDUIT MAIN EQUIP. BONDING JUMPER PER NEC 250-102(C) OR INSTALLED AT FACTORY EQUIP. GROUND. CONDUCTOR NEC 250-166 TABLE 122 BARE CU IN PVC CONDUIT NEC 250-66(A) 5/8"Ø X 10'-0" CU CLAD STEEL GROUND ROD(S) NEC 250-52(A)(5) 2 SCALE: NO SCALE ELECTRICAL GROUNDING DETAIL ELECTRODE SIZING (NEC 250.66) COPPER <2 * TOTAL OF LARGEST OR SUM OF ALL PARALLEL INCOMING UNGROUNDED PHASE CONDUCTORS. #8 ALUMINUM #6 GND CONDUCTORSERVICE ENTRANCE* 1 - 1/0 #6 #4 2/0 - 3/0 #4 #2 > 3/0 - 350 #2 1/0 > 350 - 600 1/0 3/0 > 600 - 1100 2/0 4/0 > 1100 3/0 250 COPPER ALUMINUM <1/0 2/0 - 3/0 4/0 - 250 > 250 - 500 > 500 - 900 > 900 - 1750 > 1750 1-1/2"C, 4#1 AL, #6G AL 12/28/21