Loading...
HomeMy WebLinkAboutE100 - FIRST FLOOR ELECTRICAL PLANT T NOx COMS AMDSC CO COSIM-1 S IR MANIFOLD 1 (117.9 °F)T T F2 F2 F2 F2 F2E F2 F2 F2 F2 F2 F2 F2E F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 X1 IR-1 IR-1 E2 UP TO EF-4 D A:2,4,6 A:20 +42" A:40 +42" A:40 F2 F2 F2 F2 F2 F2 F2 F2E F2E F2 F2 F2 F2E F2 F2 F2E F2 F2 F2 F2E F2 F2 F2E F2 F2 F2E F2E F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F6 F6 F6 F4 F4 F4 F4 F4 F4 F4 F1 F2 F2E 220+42" A:27 F4E F2 X1 X2 X1 J J IR-1 J IR-2 J IR-2 J E2 E2 M M M M M COMP. HA:19,21,23 UP TO EF-5 UP TO EF-6 E1 E1 D HA A A:48 A:31 A:33,35 +40" A:1 +40" A:1 +42" A:25 +42" A:37 A:30 A:24 A:12 A:14 A:16 A:18 A:32 A:74,76,78 A:10 A:8 A:22A:38A:38 COMP. HA:13,15,17 DRYER A:44 AUTO DRAIN A:47 TIRE CHANGER A:43,45 WHEEL BALANCER A:73,75 OVERFLOW PROTECTION PRES. WASH. 1 HA:25,27,29 LIFT A:49,51 AIR & ELEC. BOX A:50 LIFT A:53,55 LIFT A:57,59 LIFT A:61,63 AIR & ELEC. BOX A:52 AIR & ELEC. BOX A:54 AIR & ELEC. BOX A:56 LIFT A:65,67 AIR & ELEC. BOX A:70 M LIFT A:69,71 AIR & ELEC. BOX A:72 A:28 A:28 A:26 A:80,82,84 PRES. WASH. 2 HA:31,33,35 EF-2 F-1 A:39 EF-1 EF-1 UP TO IH-1 T TXA A:1 F4 A:1A:1 A:1A:1 A:1 A:1 A:1 A:1 A:1 A:1 A:1A:1 A:1 A:23 A:23 A:23 A:23 A:23 (ABOVE) HA:2 HA:2 HA:2 HA:2 HA:2 HA:2 HA:2 HA:2 HA:2 HA:2 HA:2 HA:2 HA:2 HA:2 HA:2HA:2 HA:2 HA:2 HA:2 HA:2 HA:2 HA:2 HA:4 HA:4 HA:4 HA:4 HA:4 HA:4 HA:4 HA:4 HA:4 HA:4 HA:4 HA:4 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HA:6 HB LC TC A:77WP A:77WP A:77WP A:77 WP A:77 WP A:41 J A:83 WP PC A:85 A:87 A:87 TCA:89 MS-1 LC A:91 T T F3E F3 F3 F3 F3 F3 F3 F3 F3E F3 F3 F3E IR-3 J A:23 HB:13 HB:13 HB:13 HB:13 HB:13 HB:13 HB:13 HB:13 HB:13 HB:13 HB:13 HB:13 E100 FIRST FLOOR ELECTRICAL PLAN DRAWING ISSUE HISTORY ADLS ISSUE: CONSTR ISSUE: COPYRIGHT 2021 210422 JP JP AS NOTED PROJECT NO: DRAWING DATE: DRAWN BY: CHECKED BY: DRAWING SCALE: CARMEL DETAIL CENTER4250 E 96th STREETINDIANAPOLIS, INDIANAA u t o m o t i v e G r o u pN BID / PERMIT ISSUE: MEP Consulting Engineers262 Tradewinds DriveSanta Rosa BeachFlorida 32459317.506.8151dave@gnaengineering.comGOODERUM & ASSOCIATES ENGINEERINGP:E:874 Cheltenham DriveAvon IN, 46123South OfficeNorth Office 11-10-21 11-10-21JEFFREY M . PE RKEY 11/10/2021 GENERAL NOTES: 1 SCALE: 1/8" = 1'-0" FIRST FLOOR ELECTRICAL PLAN 1. REFERENCE SHEET E001 FOR ABBREVIATIONS, SYMBOLS & SPECIFICATIONS. 2. LINEWORK SHOWN DASHED INDICATES CONDUIT RUN UNDER SLAB. 3. PRIOR TO ROUGH-IN VERIFY ALL LOCATIONS AND MOUNTING HEIGHTS OF DEVICES WITH OWNER AND ADJUST AS DIRECTED. 4. E.C. SHALL PROVIDE ALL RACEWAYS AND CONDUCTORS FOR HVAC INTERLOCKS AND THERMOSTATS. PROVIDE J-BOX ROUGH-IN @ +48" AT EACH T-STAT LOCATION PRIOR TO ROUGH-IN. REFER TO MECHANICAL PLANS FOR UNIT AND T-STAT LOCATIONS. COORDINATE EXACT REQUIREMENTS WITH M.C. 5. ALL WORK RECEPTACLES IN SERVICE, PARTS, AND DETAIL BAYS SHALL BE MOUNTED AT 48" AFF UNLESS OTHERWISE NOTED. 6. ALL ELECTRICAL DEVICES IN DETAIL BAY SHALL BE RATED FOR WET LOCATION SERVICE. ALL ELECTRICAL COVERS AND SWITCH PLATES SHALL BE GALVANIZED STEEL FOR SHOP AND ASSOCIATED ROOMS. 7. ALL EXIT SIGNS, EMERGENCY LIGHTING UNITS, AND NIGHT LIGHTS SHALL HAVE UNSWITCHED CONDUCTORS. CONNECT LIGHT FIXTURE TO NEAREST UNSWITCHED BRANCH LIGHTING CIRCUIT. 8. LIGHT FIXTURE TYPES HAVING AN 'E' DESIGNATION INDICATE FIXTURE HAVING INTEGRAL BATTERY INVERTER FOR EMERGENCY EGRESS LIGHTING FUNCTION. 1. MOUNT ALL DATA AND RECEPTACLES FOR WORK STATIONS AT 48" AFF. RECEPTACLES IN DETAIL BAY SHALL BE GFI TYPE. PRIOR TO ROUGH-IN VERIFY FINAL LOCATION AND HEIGHT WITH OWNER. TYPICAL. 2. PROVIDE 30A-3P FUSIBLE DISCONNECT WITH 20A CLASS CC FUSES FOR OVERHEAD DOOR POWER. 3 PHASE POWER WILL GO TO THIS DISCONNECT, THEN TO THE OVERHEAD DOOR CONTROLLER. ROUTE LINE SIDE BRANCH CIRCUITRY THRU #RC1 CONTACTOR TO ALLOW FOR MANUAL OVERRIDE CONTROL. REFERENCE DETAIL #1, SHEET E002 FOR ADDITIONAL INFORMATION. 3. IR HEATERS. PROVIDE EMT RACEWAYS FOR ALL LINE VOLTAGE CONTROLS AND BACK BOXES WITH EMT RACEWAYS FOR LOW VOLTAGE CONTROLS TO ACCESSIBLE LOCATIONS. ALL CONTROLS AND HEATER COMPONENTS BY M.C. IR HEATERS SHALL BE CONTROLLED BY SMARTCOM IR TEMPERATURE CONTROL PANEL WITH REMOTE BLACK BULB AND OA SENSOR. REFERENCE MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION. 4. E.C. SHALL INTERLOCK WIRING BETWEEN EXHAUST FAN AND MOTORIZED INTAKE HOOD. INTAKE HOOD SHALL OPEN WHEN FAN IS RUNNING. FAN AND DAMPER MOTOR SHALL BE PROVIDED BY M.C. 5. PROVIDE 120 VOLT CONNECTION TO ARMSTRONG CO SYSTEM CONTROLLER. FANS SHALL START UPON CO ALARM. CO DETECTOR BY M.C. REFERENCE HVAC DRAWINGS FOR WIRING DIAGRAMS. 6. PROVIDE DEDICATED PHOTOCELL CONTROLLED 120 VOLT BRANCH CIRCUIT TO SIGN THROUGH LIGHTING CONTRACTOR. INSTALL JUNCTION BOX ON STRUCTURE ABOVE ABOVE ACCESSIBLE CEILING. EXTEND BRANCH CIRCUITRY THRU WALL FRAMING TO SIGN. REFER TO ARCHITECTURAL SHEETS FOR ADDITIONAL INFORMATION. ELECTRICAL CONTRACTOR SHALL MAKE FINAL CONNECTIONS. COORDINATE WITH SIGN VENDOR. 7. PROVIDE CONNECTION TO OWNER SUPPLIED EQUIPMENT PER MANUFACTURER'S WRITTEN INSTRUCTIONS. FIELD VERIFY EXACT LOCATION OF EQUIPMENT. 8. OVERHEAD DOOR CONTROLLER PROVIDED BY OTHER, INSTALLED BY E.C. PROVIDE ALL REQUIRED ELECTRICAL CONNECTIONS, ROUGH-INS, ETC. FOR A COMPLETE INSTALLATION. COORDINATE ALL WORK AND INSTALLATION REQUIREMENTS WITH OVERHEAD DOOR SHOP DRAWINGS AND INSTALLER. 9. TRANSFORMER SHALL BE SUSPENDED FROM ABOVE. 10. CONTROL EXHAUST FAN WITH LIGHT SWITCH IN THIS ROOM. 11. PROVIDE AND INSTALL TIME CLOCK SIMILAR TO TORK #DG100A FOR CONTROL OF EXERIOR LIGHTING. PROVIDE A MULTI-POLE CONTACTOR (SIZED AS REQUIRED) IN NEMA 1 ENCLOSURE FOR BRANCH EXTERIOR BRANCH CIRCUITRY. TIE-IN TIME CLOCK CONTROL TO LIGHT CONTACTOR AS REQUIRED. FIELD COORDINATE TIME CLOCK SETTINGS WITH OWNER. 12. INSTALL PHOTOCELL ON NORTH SIDE OF BUILDING AT +12'-0". TIE IN PHOTOCELL TO TIME CLOCK. 13. PROVIDE TIMECLOCK FOR CONTROL OF CAR WASH LIGHTING SIMILAR TO TORK #DG100A. FIELD COORDINATE TIME CLOCK SETTINGS WITH OWNER. 14. ROUTE CAR WASH LIGHT BRANCH CIRCUITRY THRU TIME CLOCK IN ADJACENT EQUIPMENT ROOM. 15. PROVIDE (2) 3" CONDUITS W/PULL STRING ROUTED FROM TELECOM UTILITY TIE-IN POINT TO STUB-UP LOCATION IN IT ROOM. FIELD COORDINATE TIE-IN POINT WITH TELECOM UTILITIES AS REQUIRED. FIELD VERIFY CONDUIT ROUTING WITH ALL DISCIPLINES. 16. PROVIDE 34" CDX PLYWOOD FOR TELECOM SYSTEM BACKBOARD. 17. PROVIDE ALL POWER AND DATA BETWEEN INDOOR AND OUTDOOR UNITS AS REQUIRED. 18. PROVIDE SWITCH CONTROLLED MECHANICALLY HELD MULTI-POLE LIGHTING CONTACTOR IN NEMA 1 ENCLOSURE TO ALLOW FOR CONTROL OF ALL HI-BAY F2/F2E LIGHT FIXTURES. LIGHT SWITCH SHALL BE ROCKER STYLE TOGGLE SWITCH AND CONTROL CONTACTOR. KEY NOTES: # 2 SCALE: 1/4" = 1'-0" ENLARGED ELECTRICAL PLAN 2 E100 1 E003 1 1 2 2 2 3 3 3 3 3 4 5 6 7 7 8 8 8 9 10 10 12 11 3 13 14 TYPICAL 15 16 17 18 12/28/21