HomeMy WebLinkAboutM003 - HVAC DETAILSM003 HVAC DETAILS DRAWING ISSUE HISTORY ADLS ISSUE: CONSTR ISSUE: COPYRIGHT 2021 210422 JP JP AS NOTED PROJECT NO: DRAWING DATE: DRAWN BY: CHECKED BY: DRAWING SCALE: CARMEL DETAIL CENTER4250 E 96th STREETINDIANAPOLIS, INDIANAA u t o m o t i v e G r o u pN BID / PERMIT ISSUE: MEP Consulting Engineers262 Tradewinds DriveSanta Rosa BeachFlorida 32459317.506.8151dave@gnaengineering.comGOODERUM & ASSOCIATES ENGINEERINGP:E:874 Cheltenham DriveAvon IN, 46123South OfficeNorth Office 11-10-21 11-10-21 11/10/2021 30° MAX O CONCENTRIC TRANSITION MAX, 45 DEG. DIVERGING AND 60 DEG. CONVERGING OFFSET. PROVIDE MINIMUM 2" STRAIGHT SECTION AT EACH END. MAX 30 DEG. ECCENTRIC TRANSITION MAX, 30 DEG. 30° MAX NOTE: IN GENERAL, ELBOWS TO HAVE FULL TURNING RADIUS (R=A). WHERE "R" IS EQUAL TO OR GREATER THAN "A" MINIMUM RADIUS (R) = 4 INCHES. R=A A DUCT CONSTRUCTION DETAILSD 45 DEG. OCL CONNECTION TAKE OFF. HAMMER LOCKED OR FLANGED AND FULLY SEALED RECTANGULAR DUCT BRANCH AIR FLOWV.D. 45 DEG. HIGH EFFICIENCY TAKE OFF COMPLETELY SEALED ROUND SHEET METAL DUCT TO DIFFUSER 118" NOTE: DOUBLE THICKNESS TURNING VANES TO BE USED WHERE NORMAL RADIUS ELBOW IS IMPRACTICAL & WHERE ELBOW IS WITHIN 5 FT OF A BRANCH TAKE-OFF.AIR FLOWSPIRAL DUCT DOUBLE DEFLECTION REGISTER WITH INTEGRAL OBD. CURVED SPIRAL REGISTER DETAILO NOTE: SEE DWGS FOR DIRECTION DIRECT MOUNT REGISTER WITH DAMPER SEALED TO SPIRAL DUCT WITH FULL PERIMETER BUTYL GASKET AND #10 SCREWS 4" O.C. UNIFORM PATTERN. ENSURE CONNECTION IS AIR TIGHT. 0°-45° GASKET LAY-IN DIFFUSER DETAILK SECURE FLEXIBLE DUCT TO SUPPLY DIFFUSER ELBOW FITTING WITH DRAWBANDS. SHEET METAL ELBOW SEAL ALL RIBS AND CONNECTION TO DIFFUSER NECK SUPPLY DIFFUSER ACT CEILING FLEX DUCT MAXIMUM LENGTH SHALL NOT EXCEED 7'-0" REFERENCE ARCHITECTURAL REFLECTED CEILING PLAN AND ELECTRICAL LIGHTING PLAN AND COORDINATE INSTALLATION WITH ALL CEILING ELEMENTS. ROUND CHIMNEY TOP METALBESTOS FLUE RECOMMENDATIONS MANUFACTURER'S INSTALL PER NOTE FLASHING ROOF STORM COLLAR METAL ROOF AIR SPACE AROUND FLUE LISTED CONNECT TO APPLIANCE WITH B-VENT CONNECTOR PIPING SLOPE AT MINIMUM 1/4" PER FOOT IR FLUE DETAILH CAULK WATER TIGHT ATTACH TO ROOF DECK W/ #10 SHEET METAL SCREWS MINIMUM 36" ABOVE ROOF LINE METALBESTOS CONNECTOR ROUTED FULLY TO APPLIANCE NO SINGLE WALL ALLOWED. SCALE: NONE MINIMUM 3'-6" ABOVE ROOF LINE SINGLE WALL DUCTING TO FAN. STORM COLLAR ROOF METALBESTOS FLUE SCALE: NONE EXHAUST FAN TERMINAL DETAILL LISTED ROUND CHIMNEY TOP METAL ROOF FLASHING METALBESTOS FLUE PIPE BRACE TO STRUCTURE STRUCTURAL MEMBER ROOF MEMBRANE 24" CONCENTRIC DETAILM NOTE: MAINTAIN ALL CLEARANCES PER IFGC DIRECT VENTING SECTIONS. EQUIP MANUFACTURER SUPPLIED CONCENTRIC ROOF VENT RUBBER BOOT DECK FLASHING DESIGN FOR ROOFING SYSTEM. SPECIFICALLY SEAL WITH POLYURETHANE BASED SEALER, SIKAFLEX-221 OR EQUAL. SILICONE SEALANT IS NOT ACCEPTABLE FIELD INSTALL PIPE SUPPORT. BRACE TO STRUCTURE FIELD ROUTE PVC VENTING IN STRICT ACCORDANCE WITH EQUIP. MANUF. RECOMMENDATIONS. MINIMUM 3'-0" ABOVE ROOF LINE STORM COLLAR ROOF SEAL ALL JOINTS DRYER GOOSENECK DETAILN 4" SPIRAL NO SCREENS ON OUTLET TALL CONE METAL ROOF FLASHING NOTE LENGTH NOT TO MANUFACTURER'S RECOMMENDATIONS 6" SPIRAL SLEEVE BRACE TO UNDERSIDE OF ROOF STRUCTURE 4" SPRIAL GASKETED DUCTING RIVET ALL JOINTS AND SEAL WITH HIGH TEMPERATURE SEALANT. STORM COLLAR ROOF METALBESTOS FLUE LISTED ROUND CHIMNEY TOP METAL ROOF FLASHING NOTE INSTALL PER MANUFACTURER'S RECOMMENDATIONS METALBESTOS FLUE, SEAL WITH HIGH TEMPERATURE SEALANT. FRESH AIR DETAIL G DO NOT REMOVE OR DEFACE THIS PLACARD MANDATED BY IMC 504.6.5 & IRC MM1502.4.5 RISK OF FIRE LOCATION IS FEET Dryer Placard - Equal to part No. PLAC34 (888-443-7937) Post within 6'-0" feet of dryer's exhaust duct connection. HVAC contractor to fill in duct lenght for each individual installation taking into account the actual installed equivalent length including fittings used. THE MAXIMUM ALLOWABLE EXHAUST DUCT LENGTH STATED IN THE CLOTHES DRYER'S INSTALLATION INSTRUCTIONS SHALL BE EQUAL TO OR GREATER THAN THE POSTED EQUIVALENT LENGTH INDICATED ON THIS PLACARD. THE NET EQUIVALENT* LENGTH OF DRYER DUCT FROM THIS E IR HEATER WIRING DIAGRAM Relay Modual IR Heater 120V #12 w/grd IR Heater IR Heater IR Blower S-Black Bulb Sensor OA Sensor (1) Shielded Stranded twisted pair 2 C 18 AWG and (1) 4 C Solid 18 AWG Cables in 34" EMT. max 350 feet Typical Shielded 2 C 18 AWG Cable in 34" EMT on 4x4 box 10"x10" Nema 1 enclosure box (1) Shielded Stranded twisted pair 2 C 18 AWG and (1) 4 C Solid 18 AWG Cables in 3 4" EMT Max 350 feet. IR Blower IR Blower Remote Smart Com controller IR Heater IR Blower 120V #12 w/grd 120V #12 w/grd Heater Power feed L1 L2 L3 460 1 PH to 120 1 PH fused transformer M O/L FUSE O/L M MAN AUTO Armstrong AMD CO Controller by M.C. G M 115 V Interlock Power to Motorized Actuator on Intake Damper3 Ph Exhaust fan 460 V 3 Phase Combination Motor Starter with 115 V Holding Coil and HOA Switch with Pilot light by Electrical Contractor. 115 V #12 w.grd Controller power feed J CO WIRING BLOCK DIAGRAM THREE PHASE CO/NOx Sensor (2) SHIELDED STRANDED TWISTED PAIR 4 C 18 AWG CABLES IN 34" EMT BY E.C. SEE PLANS FOR LOCATIONS TYPICAL. IR Heater IR Blower SLOPE DOWNWARDS TOWARDS BURNER BY APPROXIMATELY 1/2" * * * * BEAM CLAMP EYE HOOK VERTICAL SUSPENSION CHAIN IDEAL WHERE SUPPORTS ARE INCLINED. MAXIMUM RECOMMENDED ANGLE OF INCLINATION IS 15 DEG. WHERE CHAIN SUPPORTS HAVE AN ANGLE OF INCLINATION GREATER THAN 15 DEG. AN EQUAL AND OPPOSITE SUPPORT IS RECOMMENDED. * THESE ANGLES TO BE EQUAL AND NOT MORE THAN 45° CHAIN ('U' TYPE SHOWN) 55° SUSPENSION NOTE: REFER TO MANUFACTURERS INSTALLATION INSTRUCTIONS AND INSTALL HEATER IN ACCORDANCE WITH ALL CLEARANCE AND INSTALLATION RECOMMENDATIONS. 2/0 GA CHAIN (TWISTED LINK, PLATED) TYPICAL. 15°MAX INFRARED HEATER INSTALLATION DETAILSF M SEDIMENT TRAP FILTER RACK FURNACE 3 4" PVC DRAIN, SLOPE AT MIN 1 4" PER FOOT. GALVANIZED SECONDARY DRAIN PAN, EXTEND MINIMINUM 6" PAST ENTIRE FURNACE AND DX COIL BOX UNI-STRUT RACKING FOR BOTH DRAIN PAN AND FURNACE. CONNECT TO STRUCTURE WITH 3 8" RODS. CAP AND PROVIDE WATER SHUT OFF SWITCH 20" MIN WORK AREA PVC VENT PIPING. ROUTE TO CONCENTRIC VENT TERMINAL PER MANUFACTURES RECOMMENDATIONS INSULATED OUTSIDE AIR DUCT WITH MOTORIZED AND MANUAL DAMPER. ROUTE TO WALL CAP REFRIGERATION PIPING. INSTALL PER MANUFACTURES RECOMMENDATIONS AC "N" DX COIL INSTALL MANUFACTURES DEFLECTION PLATE FOR HORZ. APPLICATION. MANUAL SHUTOFF GAS VALVE AND UNION CONDENSATE TRAP WITH TOP CLEAN OUT. SCALE: NONE HORIZONTAL FURNACE DEATILC MIN. 8" SLOPE ROOF MOUNT ACCU DETAILB PITCH POCKET COORDINATE LOCATION/TYPE WITH ROOFING CONTRACTOR INVERTED TRAP, PITCH SUCTION LINE TOWARD COMPRESSOR. PROVIDE OIL RETURN TRAPS PER MANUFACTURES PIPING RECOMMENDATIONS. MECHANICALLY FASTENED LINE SETS VIA CUSH CLAMPS AND TREATED 4x4'S REFRIGERANT TUBING WITH 1/2" WALL MIN. ARMAFLEX INSULATION. INSULATION LOCATED OUTDOORS SHALL BE PAINTED WITH UV RESISTANT ARMAFLEX PAINT. NEMA 3R DISCONNECT SIZED AND INSTALLED PER NEC. MOUNT TO SIDE OF UNIT INSTALL ALL REFRIGERATION SPECIALTIES AS INDICATED ON EQUIPMENT SCHEDULES. GALVANIZED EQUIPMENT RAIL EQUIPMENT SUPPORTS LIKE PATE EQ-1 WITH SLIP SHEET UNDER RAIL SET ON ROOF MEMBRANE AIR COOLED CONDENSER MOUNTED ON 2" SQUARE VIBRATION PAD LIKE DIVERSITECH #MP-2E ANTI-VIBRATION PAD GFCI WHERE SHOWN ON PLANS HIGH WALL UNIT DISCONNECT BY E.C. DUCTLESS MINISPLIT DETAILA MINI-WHITE TANK MINI SPLIT CONDENSATE PUMP WITH HIGH LEVEL CUT OUT. WIRE TO IDU PER MANUFACTURES INSTRUCTIONS 1/2" HOSE TO OPEN SITE HUB DRAIN PROVIDED BY P.C. PATE PORTAL ROOF CURB TYPICAL ALL LINE SETS. INSULATE AND SEAL WATER TIGHT. ALL PIPING SHALL BE SIZED PER MANUFACTURERS RECOMMENDATIONS. INSULATE SUCTION AND LIQUID LINES WITH 1/2" WALL ARMAFLEX. ALL EXTERIOR INSULATIONS SHALL BE PAINTED WITH UV RESISTANT ARMASHIELD PAINT. INVERTED SUCTION LINE TRAP. SLOPE LINE BACK TO COMPRESSOR. AIR COOLED CONDENSING UNIT GALVANIZED EQUIPMENT RAIL BY MC INSTALL PER SPECIFICATIONS AND MANUFACTURERS RECOMMENDATIONS. SCALE: NONE SCALE: NONE SCALE: NONESCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE RETURN AIR DUCTING SINGLE WALL DUCTING TO UNIT. MINIMUM 3'-6" ABOVE ROOF LINE 12/28/21