HomeMy WebLinkAboutP002 - PLUMBING DETAILSP002
PLUMBING
DETAILS &
SCHEDULES
DRAWING ISSUE HISTORY
ADLS ISSUE:
CONSTR ISSUE:
COPYRIGHT 2021
210422
JP
JP
AS NOTED
PROJECT NO:
DRAWING DATE:
DRAWN BY:
CHECKED BY:
DRAWING SCALE: CARMEL DETAIL CENTER4250 E 96th STREETINDIANAPOLIS, INDIANAA u t o m o t i v e G r o u pN BID / PERMIT ISSUE: MEP Consulting Engineers262 Tradewinds DriveSanta Rosa BeachFlorida 32459317.506.8151dave@gnaengineering.comGOODERUM & ASSOCIATES ENGINEERINGP:E:874 Cheltenham DriveAvon IN, 46123South OfficeNorth Office 11-10-21
11-10-21
11/10/2021
A+.9A
NOTE: + Actual Channel length is 122 1/2 [3112] to allow for overlap.
72"
4" MIN.
INVERT
4"
6"
4" MIN.
D TD STANDARD TRENCH DRAIN TYPICAL SECTION
SECTION VIEW
ONE SECTION SIDE VIEW
PLAN VIEW
SPECIFYING ENGINEER IS RESPONSIBLE FOR
CONCRETE ENCASEMENT AND REINFORCING
BASED UPON APPLICATION AND LOCAL CODES
INSULATED PLUMBING PIPES.
RIGID MOLDED FIBERGLASS
INSULATION
METAL PROTECTION
SHIELDS
HANGING RODS
12" MIN.
NUTS & LOCK
WASHERS
SUPPORT CHAIR
BOLTED TO CHANNEL
STEEL CHANNEL
ADEQUATE TO
CARRY LOAD
GENERAL NOTES:
1) PROTECTION SADDLES SHALL BE COPPER CLAD IF COPPER TUBE IS
USED.
2) PROVIDE INTERMEDIATE HANGING ROD SUPPORT WHERE NUMBER
OF PIPES EXCEED FIVE(5).
TRAPEZE HANGER DETAILA
S.S. CLAMPING RING
NON-INSULATED PIPE
SEALANT IN PIPE SLEEVE
URETHANE OR DOW CORNING
1/2" (MIN.) FOAM-IN-PLACE
RESILIENT FOAM PENETR.
#3-6548 SILICONE RTV
NON-INSULATED PIPE
EPDM FLASHING BOOT
WIRE MESH
STAINLESS STEEL
1/4"x1/4"
VENT THRU ROOF DETAIL GSNOW LOADING HGT. RQMTS.EXTEND VENTING PERB GAS CONNECTION DETAIL CLEAN OUT DETAILCSCALE: NONE
38"x3" STAINLESS STEEL ANCHOR BOLTS
FINISHED GRADE (SLOPE AWAY FROM CASTING)
PRE-CAST CONCRETE AJUSTING
RING OR FLANGE OF CASTING
FRAME AND COVER (SEE MANHOLE
CASTING TABLE FOR DETALS, TYP)24" RCP RISERS AS REQUIRED
2'-0" MIN. TO 3'-0" MAX
(FOR CONCRETE STRUCTURES
54" MIN. FROST LINE
MIN. (1) 4" PRE-CAST CONCRETE
ADJUSTING RINGS (TYP.)
INFLUENT 6"
ALL JOINTS SHALL BE SEALED BY AN O-RING GASKET PLUS
12" OR 34" CITY APPROVED FLEXIBLE BUTYL RESIN
CONCRETE SEALANT (ROPE) CONFORMING TO ASHALL BE
DEPENDENT ON SEASON OF INSTALLATION AND AS
DIRECTED BY ENGINEER. CONTRACTOR SHALL GROUT ALL
INTERNAL MANHOLE JOINTS WITH NON-SHRINK GROUT
KENT SEAL
JOINT DETAIL
12" MIN. TO UNDISTURBED EARTH
"CLEAN" SAND BACKFILL TO
INFLUENT AND EFFLUENT PIPESKEY NOTES:
A. DISTANCE MAY BE INCREASED BASED
ON THE CONSTITUENTS OF THE
WASTEWATER FLOWS. CONSULT CITY
PRIOR TO SHOP DRAWING SUBMITTAL.
B. MINIMUM LIQUID DEPTH MAY BE
REDUCED ON A CASE-BY-CASE BASIS
AS APPROVED BY THE AHJ.
NOTES:
1. INTERCEPTOR/SEPERATOR SHALL
CONFORM TO ASTM C478 UTILIZING 4000
PSI CONCRETE
2. EXTERIOR INSTALLATION MUST BE
CONCRETE OR CAST IRON. STEEL
INTERCEPTORS/SEPERATORS SHALL
ONLY BE INSTALLED INSIDE A BUILDING
3. CONTRACTOR MAY SUPPLY
INTERCEPTORS/SEPERATORS AS
MANUFACTURED BY JR SMITH CO.
SERIES 8500 IF INTERIOR INSTALLATION
UTILIZED
4. SIZE AS PER CODE OR LOCAL
REQUIREMENTS. THE SIZING METHOD FOR
ALL STRUCTURES MUST BE APPROVED BY
THE AHJ.
5. THE BAFFLE ORIENTATION WILL BE
DEPENDANT UPON THE APPLICATION.
6. SHOP DRAWINGS MUST BE SUBMITTED TO
THE AHJ FOR REVIEW AND APPROVAL.
7. TOP OF CASTING SHALL EXTEND .2Ø FEET
MIN. ABOVE FINISHED GRADE UNLESS
APPROVED BY THE CITY. CASTING MUST
NOT BE WITHIN 1'-0" HORIZONTAL
DISTANCE OF ANY PAVED OR CONCRETE
SURFACE.
OUTSIDE DIAMETER + 1'-0" FOR PRE-CAST
12" MIN. CRUSHED #8 STONE MAT
FOR LEVELING AND SUPPORT
#2 STONE AS REQUIRED BY CTRWD FOR
UNSTABLE SOIL CONDITIONS - DEPTH
TO STABLE GROUND PER CITY
6" REINFORCED CONCRETE
NO CORE WILL BE PERMITTED WITHIN
6" OD INTERNAL OR EXTERNAL JOINTS
CORE DRILLED OPENING WITH RESILIENT
CONNECTOR OR CAST-IN-PLACE A-LOCK OR
CITY APPROVED EQUAL (TYP. ALL PIPE
PENETRATIONS).
EFFLUENT
6"
10" MIN.
12" MAX.
1' TYP.
1'-0" MIN.
2'-0" DIA. (TYP.)
6" OPENING
8" (SEE NOTE A)
LIQUID DEPTH 30" MINS. TO
78" MAX (SEE NOTE B)
14" STAINLESS
STEEL
SUPPORT
LOCATION
18" OR MORE ABOVE THE
100-YEAR FLOOD ELEVATION
OF ALL WATERWAYS
LESS THAN 18" ABOVE THE
100-YEAR FLOOD ELEVATION
OF ALL WATERWAYS
OWNERSHIP
PRIVATE
LID
LETTERING
"SANITARY SEWER"
EAST JORDAN 1Ø22ZIGS OR
NEENAH R-1772
MANHOLE CASTING TABLE
COVERMODEL
EAST JORDAN 1Ø221ZIPT
HEAVY DUTY SOLID
HEAVY DUTY SOLID
20"
6" (SEE NOTE A)
L OIL/ SAND SEPARATOR DETAIL
1,000 GALLON
COMPRESSED AIR
MAIN SEE PLANS FOR
SIZE.
INSTALL 3/4" FULL PORT SHUT-OFF
BALL VALVES ON ALL COMPRESSED
AIR CONNECTIONS.
J COMPRESSED AIR LIFT CONNECTION DETAIL
NOTE:
1. AIR DROP LOCATIONS SHALL BE COORDINATED WITH OWNER PRIOR TO ROUGH-IN.
2. ALL QUICK CONNECT FITTINGS BY OWNER.
3. COORDINATE HEIGHT OF ALL AIR MAINS WITH OWNER. GENERALLY MOUNT PIPING AS HIGH
AS ALLOWABLE.
3/4" CONNECTION TO
HOSE REEL AT ROOF
FRAMING ELEVATION
WHERE REQUIRED.
CONNECT TO LIFT FITTING.
COORDINATE CONNECTION WITH
LIFT MANUFACTURER
1" TOP TAKE OFF WITH
VALVE AT MAIN ON ALL
DROPS.
E WATER SERVICE DIAGRAM
ELBOW
ELBOW
UNION
APPLIANCE
6" DIRT LEG
WITH CAP
FIELD VERIFY LENGTH
AGA RATED GAS STOP
MAXITROL 2 PSIG - 8" W.C. GAS
REGULATOR, VENT LINE, PETES
PLUG, DIRT LEG AND UNION.
SCALE: NONE SCALE: NONE SCALE: NONE
SCALE: NONE
SCALE: NONE
SCALE: NONE
SCALE: NONE
ROOF GAS PIPING HANGER DETAILH
MIRO #1.5 PIPE SUPPORT
W/ ACCESSORIES
ACCESSORIES
- 1.5 pipe guide
- 1.5 spacer
- Support pad
- Eternabond } 2-sided tape
2"
2"
2"
1-1/2" METER
18" AFF MIN. TO 42" MAX.
1/2" CW
1/2" HW
1-1/2" VENT
AUTOMATIC CLOTHES WASHER BOX -
RECESSED WALL BOX W/ FACE PLATE
(PROVIDE FIRE RATED BOX FOR ALL
BOXES LOCATED ON FIRE RATED WALLS)
SHUT-OFF VALVE WITH THREADED
HOSE CONNECTION
2" P-TRAP
3" DRAIN RISER
FLOOR LINE
CLOTHES WASHER BOX DETAILF
3" SANITARY SEWER
BRANCH
2" STANDPIPE
3"
SCALE: NONE
3/4" TOP TAKE OFF WITH
VALVE AT MAIN ON ALL
DROPS.
COMPRESSED AIR
MAIN SEE PLANS FOR
SIZE.
INSTALL 3/4" FULL PORT SHUT-OFF
BALL VALVE ON ALL COMPRESSED
AIR CONNECTIONS.
ALL DROPS SHALL INCLUDE DIRT
LEG AND SHUT-OFF. QUICK
CONNECT FITTINGS BY OWNERS
SUPPLIER. VERIFY FITTING TYPE
WITH OWNER PRIOR TO
ROUGH-IN.
K COMPRESSED AIR CONNECTION DETAIL
NOTE:
1. AIR DROP LOCATIONS SHALL BE COORDINATED WITH OWNER PRIOR TO ROUGH-IN.
2. ALL QUICK CONNECT FITTINGS BY OWNER.
3. COORDINATE HEIGHT OF ALL AIR MAINS WITH OWNER. GENERALLY MOUNT PIPING AS HIGH
AS ALLOWABLE.
SCALE: NONE
SCALE: NONE
12/28/21