Loading...
HomeMy WebLinkAboutP002 - PLUMBING DETAILSP002 PLUMBING DETAILS & SCHEDULES DRAWING ISSUE HISTORY ADLS ISSUE: CONSTR ISSUE: COPYRIGHT 2021 210422 JP JP AS NOTED PROJECT NO: DRAWING DATE: DRAWN BY: CHECKED BY: DRAWING SCALE: CARMEL DETAIL CENTER4250 E 96th STREETINDIANAPOLIS, INDIANAA u t o m o t i v e G r o u pN BID / PERMIT ISSUE: MEP Consulting Engineers262 Tradewinds DriveSanta Rosa BeachFlorida 32459317.506.8151dave@gnaengineering.comGOODERUM & ASSOCIATES ENGINEERINGP:E:874 Cheltenham DriveAvon IN, 46123South OfficeNorth Office 11-10-21 11-10-21 11/10/2021 A+.9A NOTE: + Actual Channel length is 122 1/2 [3112] to allow for overlap. 72" 4" MIN. INVERT 4" 6" 4" MIN. D TD STANDARD TRENCH DRAIN TYPICAL SECTION SECTION VIEW ONE SECTION SIDE VIEW PLAN VIEW SPECIFYING ENGINEER IS RESPONSIBLE FOR CONCRETE ENCASEMENT AND REINFORCING BASED UPON APPLICATION AND LOCAL CODES INSULATED PLUMBING PIPES. RIGID MOLDED FIBERGLASS INSULATION METAL PROTECTION SHIELDS HANGING RODS 12" MIN. NUTS & LOCK WASHERS SUPPORT CHAIR BOLTED TO CHANNEL STEEL CHANNEL ADEQUATE TO CARRY LOAD GENERAL NOTES: 1) PROTECTION SADDLES SHALL BE COPPER CLAD IF COPPER TUBE IS USED. 2) PROVIDE INTERMEDIATE HANGING ROD SUPPORT WHERE NUMBER OF PIPES EXCEED FIVE(5). TRAPEZE HANGER DETAILA S.S. CLAMPING RING NON-INSULATED PIPE SEALANT IN PIPE SLEEVE URETHANE OR DOW CORNING 1/2" (MIN.) FOAM-IN-PLACE RESILIENT FOAM PENETR. #3-6548 SILICONE RTV NON-INSULATED PIPE EPDM FLASHING BOOT WIRE MESH STAINLESS STEEL 1/4"x1/4" VENT THRU ROOF DETAIL GSNOW LOADING HGT. RQMTS.EXTEND VENTING PERB GAS CONNECTION DETAIL CLEAN OUT DETAILCSCALE: NONE 38"x3" STAINLESS STEEL ANCHOR BOLTS FINISHED GRADE (SLOPE AWAY FROM CASTING) PRE-CAST CONCRETE AJUSTING RING OR FLANGE OF CASTING FRAME AND COVER (SEE MANHOLE CASTING TABLE FOR DETALS, TYP)24" RCP RISERS AS REQUIRED 2'-0" MIN. TO 3'-0" MAX (FOR CONCRETE STRUCTURES 54" MIN. FROST LINE MIN. (1) 4" PRE-CAST CONCRETE ADJUSTING RINGS (TYP.) INFLUENT 6" ALL JOINTS SHALL BE SEALED BY AN O-RING GASKET PLUS 12" OR 34" CITY APPROVED FLEXIBLE BUTYL RESIN CONCRETE SEALANT (ROPE) CONFORMING TO ASHALL BE DEPENDENT ON SEASON OF INSTALLATION AND AS DIRECTED BY ENGINEER. CONTRACTOR SHALL GROUT ALL INTERNAL MANHOLE JOINTS WITH NON-SHRINK GROUT KENT SEAL JOINT DETAIL 12" MIN. TO UNDISTURBED EARTH "CLEAN" SAND BACKFILL TO INFLUENT AND EFFLUENT PIPESKEY NOTES: A. DISTANCE MAY BE INCREASED BASED ON THE CONSTITUENTS OF THE WASTEWATER FLOWS. CONSULT CITY PRIOR TO SHOP DRAWING SUBMITTAL. B. MINIMUM LIQUID DEPTH MAY BE REDUCED ON A CASE-BY-CASE BASIS AS APPROVED BY THE AHJ. NOTES: 1. INTERCEPTOR/SEPERATOR SHALL CONFORM TO ASTM C478 UTILIZING 4000 PSI CONCRETE 2. EXTERIOR INSTALLATION MUST BE CONCRETE OR CAST IRON. STEEL INTERCEPTORS/SEPERATORS SHALL ONLY BE INSTALLED INSIDE A BUILDING 3. CONTRACTOR MAY SUPPLY INTERCEPTORS/SEPERATORS AS MANUFACTURED BY JR SMITH CO. SERIES 8500 IF INTERIOR INSTALLATION UTILIZED 4. SIZE AS PER CODE OR LOCAL REQUIREMENTS. THE SIZING METHOD FOR ALL STRUCTURES MUST BE APPROVED BY THE AHJ. 5. THE BAFFLE ORIENTATION WILL BE DEPENDANT UPON THE APPLICATION. 6. SHOP DRAWINGS MUST BE SUBMITTED TO THE AHJ FOR REVIEW AND APPROVAL. 7. TOP OF CASTING SHALL EXTEND .2Ø FEET MIN. ABOVE FINISHED GRADE UNLESS APPROVED BY THE CITY. CASTING MUST NOT BE WITHIN 1'-0" HORIZONTAL DISTANCE OF ANY PAVED OR CONCRETE SURFACE. OUTSIDE DIAMETER + 1'-0" FOR PRE-CAST 12" MIN. CRUSHED #8 STONE MAT FOR LEVELING AND SUPPORT #2 STONE AS REQUIRED BY CTRWD FOR UNSTABLE SOIL CONDITIONS - DEPTH TO STABLE GROUND PER CITY 6" REINFORCED CONCRETE NO CORE WILL BE PERMITTED WITHIN 6" OD INTERNAL OR EXTERNAL JOINTS CORE DRILLED OPENING WITH RESILIENT CONNECTOR OR CAST-IN-PLACE A-LOCK OR CITY APPROVED EQUAL (TYP. ALL PIPE PENETRATIONS). EFFLUENT 6" 10" MIN. 12" MAX. 1' TYP. 1'-0" MIN. 2'-0" DIA. (TYP.) 6" OPENING 8" (SEE NOTE A) LIQUID DEPTH 30" MINS. TO 78" MAX (SEE NOTE B) 14" STAINLESS STEEL SUPPORT LOCATION 18" OR MORE ABOVE THE 100-YEAR FLOOD ELEVATION OF ALL WATERWAYS LESS THAN 18" ABOVE THE 100-YEAR FLOOD ELEVATION OF ALL WATERWAYS OWNERSHIP PRIVATE LID LETTERING "SANITARY SEWER" EAST JORDAN 1Ø22ZIGS OR NEENAH R-1772 MANHOLE CASTING TABLE COVERMODEL EAST JORDAN 1Ø221ZIPT HEAVY DUTY SOLID HEAVY DUTY SOLID 20" 6" (SEE NOTE A) L OIL/ SAND SEPARATOR DETAIL 1,000 GALLON COMPRESSED AIR MAIN SEE PLANS FOR SIZE. INSTALL 3/4" FULL PORT SHUT-OFF BALL VALVES ON ALL COMPRESSED AIR CONNECTIONS. J COMPRESSED AIR LIFT CONNECTION DETAIL NOTE: 1. AIR DROP LOCATIONS SHALL BE COORDINATED WITH OWNER PRIOR TO ROUGH-IN. 2. ALL QUICK CONNECT FITTINGS BY OWNER. 3. COORDINATE HEIGHT OF ALL AIR MAINS WITH OWNER. GENERALLY MOUNT PIPING AS HIGH AS ALLOWABLE. 3/4" CONNECTION TO HOSE REEL AT ROOF FRAMING ELEVATION WHERE REQUIRED. CONNECT TO LIFT FITTING. COORDINATE CONNECTION WITH LIFT MANUFACTURER 1" TOP TAKE OFF WITH VALVE AT MAIN ON ALL DROPS. E WATER SERVICE DIAGRAM ELBOW ELBOW UNION APPLIANCE 6" DIRT LEG WITH CAP FIELD VERIFY LENGTH AGA RATED GAS STOP MAXITROL 2 PSIG - 8" W.C. GAS REGULATOR, VENT LINE, PETES PLUG, DIRT LEG AND UNION. SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE ROOF GAS PIPING HANGER DETAILH MIRO #1.5 PIPE SUPPORT W/ ACCESSORIES ACCESSORIES - 1.5 pipe guide - 1.5 spacer - Support pad - Eternabond } 2-sided tape 2" 2" 2" 1-1/2" METER 18" AFF MIN. TO 42" MAX. 1/2" CW 1/2" HW 1-1/2" VENT AUTOMATIC CLOTHES WASHER BOX - RECESSED WALL BOX W/ FACE PLATE (PROVIDE FIRE RATED BOX FOR ALL BOXES LOCATED ON FIRE RATED WALLS) SHUT-OFF VALVE WITH THREADED HOSE CONNECTION 2" P-TRAP 3" DRAIN RISER FLOOR LINE CLOTHES WASHER BOX DETAILF 3" SANITARY SEWER BRANCH 2" STANDPIPE 3" SCALE: NONE 3/4" TOP TAKE OFF WITH VALVE AT MAIN ON ALL DROPS. COMPRESSED AIR MAIN SEE PLANS FOR SIZE. INSTALL 3/4" FULL PORT SHUT-OFF BALL VALVE ON ALL COMPRESSED AIR CONNECTIONS. ALL DROPS SHALL INCLUDE DIRT LEG AND SHUT-OFF. QUICK CONNECT FITTINGS BY OWNERS SUPPLIER. VERIFY FITTING TYPE WITH OWNER PRIOR TO ROUGH-IN. K COMPRESSED AIR CONNECTION DETAIL NOTE: 1. AIR DROP LOCATIONS SHALL BE COORDINATED WITH OWNER PRIOR TO ROUGH-IN. 2. ALL QUICK CONNECT FITTINGS BY OWNER. 3. COORDINATE HEIGHT OF ALL AIR MAINS WITH OWNER. GENERALLY MOUNT PIPING AS HIGH AS ALLOWABLE. SCALE: NONE SCALE: NONE 12/28/21