HomeMy WebLinkAboutG001_LIFE SAFETY PLAN-Layout1G001
CODE AND LIFE
SAFETY PLAN
ALL IDEAS, DESIGNS AND PLANS INDICATED OR
REPRESENTED BY THESE DRAWINGS ARE OWNED
BY, AND THE PROPERTY OF STUART R SHADE, RA.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE
FOR ALL DIMENSIONS ON THE JOB SITE. ALL RIGHTS
RESERVED, EXCEPT FOR USES EXPRESSLY
PERMITTED IN WRITING.
SHEET NUMBER:
CERTIFICATION:PROJECT :PROPOSED PROFESSIONAL BUILDINGBUILDING 812750 MEETING HOUSE RDREV 1: CARMEL, INDIANA 46032LOT 8 PERMIT SET 12_20_21SRS ARCHITECTS
200 S RANGELINE RD , #226
INC
CARMEL, INDIANA 46032
PHONE: 317-989-6248
E-MAIL : sshade@mitschdesign.com
TANNIARATUSAERIGTSRTR.HSSTATE OFEED
DE
R EAIDITCHCAR0003418416 APRIL ' 21VILAGE CENTER SHOPPESSCALE:
2
3/16" = 1' - 0"
LIFE SAFETY PLAN
SCALE:
1
3/16" = 1' - 0"
LIFE SAFETY PLAN
CODE ANALYSIS
PROPOSED AREA OF NEW CONSTRUCTION TOTAL LEVEL 1 - 1574 SQ FT
CONSTRUCTION TYPE VB
ALLOWABLE AREA
FIRE PROTECTION - FULL
MOP SINK
WATER COOLER - BOTTLED WATER PROVIDED
OCCUPANCY CLASSIFICATION LEVEL 1 - B - BUSINESS
OCCUPANCY LEVEL 1 OFFICE - 12 PER TABLE 1004.1.2
EXITS REQUIRED LEVEL ONE 1 PER TABLE 1021.2 LESS THAN 49 PER PROPOSED SUITES
EXITS REQUIRED LEVEL TWO 1 PER APARTMENT TABLE 1021.2 LESS THAN 29
DEAD END CORRIDORS NONE - BUILDINGS REQUIRING ONLY ONE EXIT
EGRESS DOOR HARDWARE REQUIREMENTS
EGRESS DOOR SWING
NO REQUIREMENT PER 1008.1.10
NO REQUIREMENT PER 1008.1.2
MAX TRAVEL DISTANCE MEASURED 40' - ALLOWABLE 75' - B OCCUPANCY
STAIRS NON-ENCLOSED PER 1009.3 EX 1
LEVEL 2 - R2 - APARTMENT
LEVEL 1 - U - PRIVATE GARAGE
B - 9000 SQ FT - 2 STORIES
R2 - 7000 SQ FT - 2 STORIES
U - 5500 SQ FT - 1 STORY
LEVEL 1 GARAGE - 3 PER TABLE 1004.1.2
LEVEL 2 RESIDENTIAL - 8 PER TABLE 1004.1.2
(1) HR AREA SEPARATION
AT LEVEL ONE CEILING
EXIT
LEVEL 1 - B (OFFICE) U (GARAGE) FULLY SPRINKLED
LEVEL 2 - R2 - SPRINKLED
REQUIRED SEPARATION (1) HR REQUIRED BETWEEN B AND U - U305
(1) HR REQUIRED BETWEEN R AND B, U TABLE 508.4
US GYP - RC-2601 / GA-FC 5406
PROPOSED (2) HR AREA SEPARATION
PROPOSED (1) HR AREA SEPARATION
EXIT
B
OCCUPANCY
BUSINESS
EXIT
RESTROOMS PER INDIANA CODE
1 PROVIDED PER EACH COMMERCIAL SPACE
DRINKING FOUNTAIN
BUSINESS OFFICE - 1200 SQ FT
GARAGE - 374 SQ FT
TOTAL LEVEL 2 - 1396 SQ FT
APPLICABLE CODES
CODE DESCRIPTION COMPRISED OF
GENERAL ADMINISTRATION
RULES
GENERAL ADMINISTRATION
RULES (GAR) (UPDATED 8.1.2014)
(AMENDED 12.1.2014)
675 IAC 12
BUILDING CODE
(INDIANA AMENDMENTS)
2014 INDIANA BUILDING CODE (675
IAC 13-2.6)
EFFECTIVE DECEMBER 1, 2014
2012 INTERNATIONAL
BUILDING CODE 675 IAC 13-2.6
2014 INDIANA FIRE CODE (IFC)
EFFECTIVE DECEMBER 1, 2014
2012 INDIANA PLUMBING CODE
(IPC)
EFFECTIVE DECEMBER 24, 2012
2009 INDIANA ELECTRICAL CODE (IEC)
EFFECTIVE AUGUST 26, 2009
2014 INDIANA MECHANICAL CODE (675
IAC 18-1.6) EFFECTIVE DECEMBER 1,
2014
2014 INDIANA BUILDING CODE
CHAPTER 11 - ACCESSIBILITY
2010 INDIANA ENERGY CONSERVATION
CODE (IECC)
EFFECTIVE MAY 6, 2010
INDIANA BUILDING REHABILITATION
STANDARD (GAR)
(UPDATED 12.22.06)
(REPEALED 3.18.08 READOPTED 7.3.18
2012 INTERNATIONAL FIRE CODE
675 IAC 22-2.5
2006 INTERNATIONAL PLUMBING
CODE
675 IAC 16-1.4
2008 NFPA 70
675 IAC 17-1.8
2012 INTERNATIONAL MECHANICAL
CODE
675 IAC 18-1.6
675 IAC 13-2.6-12 CHAPTER 11
ASHRAE STANDARD 90.1, 2010
675 IAC 19-4
675 IAC 12-8
FIRE CODE
(INDIANA AMENDMENTS)
PLUMBING CODE
(INDIANA AMENDMENTS)
ELECTRICAL CODE
(INDIANA AMENDMENTS)
MECHANICAL CODE
(INDIANA AMENDMENTS)
HANDICAPPED ACCESSIBILITY
CODE (INDIANA AMENDMENTS)
ENERGY CODE
(INDIANA AMENDMENTS)
BUILDING REHABILITATION
STANDARD
(INDIANA AMENDMENTS)
ELEVATOR SAFETY CODE 2011 INDIANA ELEVATOR SAFETY CODE
(IESC)
(UPDATED 9-28-11)
675 IAC 21 - ANSI / ASMEA17.1, 2007
ANSI / ASME A90.1, 2003
ANSI / A10.4, 2004
ASME / A18.1, 2005
2014 INDIANA FUEL GAS CODE
IFGC - EFFECTIVE 12.1.14
A117.1 ACCESSABLE AND USABLE
BUILDINGS AND FACILITIES, 2009
EDITION
FUEL GAS CODE
(INDIANA AMENDMENTS)
2012 INTERNATIONAL FUEL GAS
CODE
675 IAC 25.3
BUILDING TOTAL AREA - 2970 SQ FT
BUILDING DEMISING WALLS SHALL BE (2) HR WALLS
R2
OCCUPANCY
APARTMENT
R2
OCCUPANCY
APARTMENT
U
OCCUPANCY
GARAGE
(1) HR AREA SEPARATION
AT LEVEL ONE CEILING
PROPOSED DECK
(2) HR
SEPARATION WALL
(2) HR
SEPARATION WALL
(2) HR
SEPARATION WALL
(2) HR
SEPARATION WALL
(1) HR
SEPARATION WALL
01/11/22