HomeMy WebLinkAboutM500 - MECHANICAL DETAILSSQUARE CEILING DIFFUSER INSTALLATION DETAIL
SCALE: NOT TO SCALE
CEILING MOUNTED SUPPLY REGISTER INSTALLATION DETAIL
NOT TO SCALE
CEILING
INSULATED FLEXIBLE DUCT.
SIZE SAME AS SCHEDULED
DIFFUSER NECK SIZE
SUPPLY DUCT
CEILING DIFFUSER W/
MANUAL VOLUME DAMPER
INSULATED FLEX DUCT
CEILING
SUPPLY AIR REGISTER
WITH OPPOSED
BLADE
VOLUME DAMPER
SUPPLY DUCT
RADIATION DAMPER
AT RATED CEILINGS
CIRCULATING FAN MOUNTING DETAIL
NOT TO SCALE
NOTES:
1. ALL DRYER EXHAUST DUCT JOINTS SHALL OVER LAP IN THE DIRECTION OF AIR FLOW
2. NO SCREWS SHALL BE ALLOWED IN THE DRYER EXHAUST DUCT AND ALL
JOINTS SHALL BE SEALED WITH FOIL FACED TAPE.
3. DRYER EXHAUST SYSTEM IS DESIGNED BASED ON MANUFACTURER
RECOMMENDEDWASHER/DRYER UNITS. CONTRACTOR SHALL USE SHEET METAL ROUND DUCTWORK
AND MINIMIZE THE USE OF FLEXIBLE DUCTWORK.
MAXIMUM LENGTH OF 4 INCH DIAMETER RIGID METAL DUCT:
No. OF ELBOW FEET
0 90
1 60
2 45
3 35
STACKED DRYER EXHAUST DETAIL
SCALE: NOT TO SCALE
4 25
CEILING
EXTERIOR WALL
90°, 4"∅RADIUS
ELBOW, TYPICAL
WASHER
4"∅RIGID DUCT
DRYER
INSTALL AS PER
MANUFACTURER'S
INSTRUCTIONS.
PORTION OF EXTERIOR WALL
LOUVER WITH BACK-DRAFT
FLAPPER.
REFER TO ARCHITECTURAL
DRAWINGS.
FLEXIBLE CONNECTION
SIDEWALL PROPELLER FAN DETAIL
NOT TO SCALE
EXHAUST AIR FLOW
PROVIDE
NECESSARY
SUPPORT
FAN GUARD
PROPELLER FAN
GRAVITY OPERATED
BACKDRAFT DAMPER
WIRE MESH
SCREEN
WALL
FAN HOUSING
DIRECT OR
BELT DRIVEN
MOTOR
ANGLE IRON SUPPORT
FRAME ANCHORED TO
WALL
SUPPLY AIR FLOW
SLAB
DIRECT DRIVE CIRCULATING
FAN. SEE PARKING LEVEL
PLANS FOR LOCATION.
PREFABRICATED FAN
GUARD ON BOTH SIDES
SLAB
ALL THREADED ROD WITH
SPRING TYPE HANGERS
7'-0" MINMOORE ENGINEERING
SERVICES, INC.
6340 LaPas Trail
Indianapolis, IN 46268
Phone (317) 291-1052
FAX (317) 298-2729R
I
G EEIS
PE60860351
No.REENIGNELANOISSEFORPDOUGLAS.RMOO
RET R
NNDIA A
STATE OF DE ARCHITECT CLIENT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20010THE SIGNATURECARMELCARMEL, INENGINEERM500MECHANICAL DETAILSPERMIT SET
04.23.2021
10/12/21