HomeMy WebLinkAboutS002ABBREVIATION LEGEND
ABBR ABBR
AB ANCHOR BOLT
DEFINITION
ACI AMERICAN CONCRETE INSTITUTE
AFF ABOVE FINISHED FLOOR
AISC AMERICAN INSTITUTE OF STEEL CONSTR'N.
ARCH ARCHITECT(URAL)
BFF BELOW FINISHED FLOOR
B/'X' BOTTOM OF REFERENCED ITEM
BLW BELOW
CIP CAST IN PLACE
CJ CONTROL JOINT
CNJ CONSTRUCTION JOINT
CL CENTERLINE
CLR CLEAR(ANCE)
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONSTR CONSTRUCTION
CONT CONTINUOUS
DIA DIAMETER
DL DEAD LOAD
EA EACH
EIFS EXTERIOR INSULATION & FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
EQ EQUAL
EQUIV EQUIVALENT
EW EACH WAY
EX EXISTING
EXT EXTERIOR
FDN FOUNDATION
FF FINISHED FLOOR
FS FAR SIDE
FTG FOOTING
FV FIELD VERIFY
GA GAGE (GAUGE)
GALV GALVANIZED
GC GENERAL CONTRACTOR
GRAN GRANULAR
H HIGH (HEIGHT)
HK HOOK
HAS HEADED ANCHOR STUD
INFO INFORMATION
INT INTERIOR
INV INVERT
JBE JOIST BEARING ELEVATION
JST JOIST
JT JOINT
KO KNOCK OUT
KSI KIPS PER SQUARE INCH
L LONG (LENGTH)
Ld TENSION DEVELOPMENT LENGTH
LB 'L' BEAM
DBA DEFORMED BAR ANCHOR
LL LIVE LOAD
COLL COLLATERAL
LLH LONG-LEG HORIZONTAL
LLO LONG-LEG OUTSTANDING
LLV LONG-LEG VERTICAL
LONG LONGITUDINAL
LWC LIGHTWEIGHT CONCRETE
MAX MAXIMUM
MC MOMENT CONNECTION
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MTL METAL
NIC NOT IN CONTRACT
NO NUMBER
NS NEAR SIDE
NTS NOT TO SCALE
NWC NORMAL WEIGHT CONCRETE
OC ON CENTER
OD OUTSIDE DIAMETER
IBC INTERNATIONAL (INDIANA) BUILDING CODE
OF OUTSIDE FACE
PAF POWDER-ACTUATED FASTENER
PCF POUNDS PER CUBIC FOOT
PDF POWER-DRIVEN FASTENER
PL PLATE
PLF POUNDS PER LINEAL FOOT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PPT PRESSURE PRESERVATIVE TREATED
KSF KIPS PER SQUARE FOOT
QTY QUANTITY
REF REFER TO (REFERENCE)
REQD REQUIRED
RO ROUGH OPENING
RTU ROOF TOP UNIT
SCHED SCHEDULE
SDI STEEL DECK INSTITUTE
SHT SHEET
SIM SIMILAR
SJI STEEL JOIST INSTITUTE
SOG SLAB ON GRADE
SPECS SPECIFICATIONS
STRUCT STRUCTURAL
T&B TOP AND BOTTOM
THK THICK(NESS)
T/'X' TOP OF REFERENCED ITEM
TRANSV TRANSVERSE
TYP TYPICAL
UNEXC UNEXCAVATED
VERT VERTICAL
W WIDE (WIDTH)
WP WORKING POINT
WWF WELDED WIRE FABRIC
PCI PRECAST CONCRETE INSTITUTE
HC HOLLOW CORE
PC PRECAST CONCRETE
ABV ABOVE
ADDL ADDITIONAL
ADJ ADJUSTABLE
BRDG BRIDGING
BB BOND BEAM
BLDG BUILDING
AISI AMERICAN IRON & STEEL INSTITUTE
ALT ALTERNATE
ASTM AMERICAN SOCIETY FOR TESTING & MATLS.
AWS AMERICAN WELDING SOCIETY
BRG BEARING
BS BOTH SIDES
AGG AGGREGATE
BM BEAM
BOT BOTTOM
BP BASE PLATE
BTWN BETWEEN
CANT CANTILEVER
C/C CENTER TO CENTER
CB CONCRETE BEAM
CC CONCRETE COLUMN
CFS COLD-FORMED STEEL
CTR CENTER
CTRD CENTERED
DIAG DIAGONAL
DIM DIMENSION
DN DOWN
DTL DETAIL
DWG DRAWING
DWL DOWEL
EF EACH FACE
ENG ENGINEER
ES EACH SIDE
EQ SPA EQUALLY SPACED (EQUAL SPACING)
FD FLOOR DRAIN
FIN FINISH
FLG FLANGE
ABBR
FT FOOT (FEET)
GB GRADE BEAM
HD HOLD DOWN
HORIZ HORIZONTAL
ID INSIDE DIAMETER
ISO ISOLATION
KIP 1,000 POUNDS
LP LOW POINT
SW SHORT WAY
LGSF LIGHT GAUGE STEEL FRAMING
HP HIGH POINT
LW LONG WAY
LVL LAMINATED VENEER LUMBER
MOM MOMENT
OA OVERALL
OH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OSB ORIENTED STRAND BOARD
PLYWD PLYWOOD
PSL PARALLEL STRAND LUMBER
PNL PANEL
PROJ PROJECTION
PTD PAINTED
PRTN PARTITION
R RADIUS
REV REVISION (REVISED)
CW CONCRETE WALL
RTN RETURN
RF ROOF
RW RETAINING WALL
SE SLAB EDGE
SECT SECTION
SL SLOPE
SPA SPACE (S)(D)(ING)
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STL STEEL
STR STRENGTH
SW SHEAR WALL (OCCASSIONAL)
PT POST TENSIONED
SYMM SYMMETRICAL
TEMP TEMPERATURE
TOPG TOPPING
WF WALL FOOTING
W/ WITH
WD WOOD
SSE SPECIALTY STRUCTURAL ENGINEER
D DEEP (DEPTH)
ACIP AUGERED CAST IN PLACE PILE
DP DRILLED PIER
IF INSIDE FACE
INDOT INDIANA DEPARTMENT OF TRANSPORTATION
CRSI CONCRETE REINFORCING STEEL INSTITUTE
SER STRUCTURAL ENGINEER OF RECORD
NDS NATIONAL DESIGN SPEC'N. FOR WOOD
ADDM ADDENDUM
ANCH ANCHORAGE
APPROX APPROXIMATE
ASSY ASSEMBLY
AVG AVERAGE
BLKG BLOCKING
CAIS CAISSON
CAPY CAPACITY
DEG DEGREE
ECC ECCENTRIC
EXC EXCAVATE (EXCAVATION)
FABR FABRICATE (FABRICATOR)
GWB GYPSUM WALL BOARD
INCR INCREASE
INSUL INSULATE (INSULATION)
LNTL LINTEL
MATL MATERIAL
MEZZ MEZZANINE
NOM NOMINAL
NRC NOISE REDUCTION COEFFICIENT
PARTN PARTITION
PERIM PERIMETER
PLBG PLUMBING
PREFAB PREFABRICATED
PSC PRESTRESSED CONCRETE
PVMT PAVEMENT
QTR QUARTER
SCT STRUCTURAL CLAY TILE
STIFF STIFFENER
T&G TONGUE & GROOVE
TD TRENCH DRAIN
UNO UNLESS NOTED OTHERWISE
TF TRENCH FOOTING
GLULAM GLUE LAMINATED WOOD
TB TIE BEAM
DT DOUBLE TEE
LBS POUNDS
IT INVERTED TEE BEAM
RB RECTANGULAR BEAM (PRECAST)
APA AMERICAN PLYWOOD ASSOCIATION
O/O OUT TO OUT
SBCA STRUCTURAL BUILDING COMPONENTS ASSN.
TPI TRUSS PLATE INSTITUTE
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
WTCA WOOD TRUSS COUNCIL OF AMERICA
DEFINITION DEFINITION
WRDA WATER REDUCING ADMIXTURE
AESS ARCHITECTURALLY EXPOSED STRUCT. STL.
WPS WELD PROCEDURE SPECIFICATION
COLUMN FOOTING SCHEDULE
FOOTING
MARK
FOOTING SIZE
WIDTH x LENGTH x DEPTH
REINFORCING
(EACH WAY)
F4.0 4'-0" 4'-0" 1'-4" (5) #5 x 3'-6"
F5.0 5'-0" 5'-0" 1'-6" (5) #6 x 4'-6"
F6.0 6'-0" 6'-0" 1'-10" (7) #6 x 5'-6"
F7.0 7'-0" 7'-0" 2'-2" (7) #7 x 6'-6"
F8.0 8'-0" 8'-0" 2'-4" (8) #7 x 7'-6"
F9.0 9'-0" 9'-0" 2'-8" (8) #9 x 8'-6"
F10.0 10'-0" 10'-0" 2'-10" (8) #9 x 9'-6"
F11.0 11'-0" 11'-0" 3'-0" (9) #9 x 10'-6"
F12.0 12'-0" 12'-0" 3'-4" (11) #9 x 11'-6"
F13.0 13'-0" 13'-0" 3'-6" (13) #9 x 12'-6"
NOTES:
1. CENTER FOOTINGS BENEATH COLUMNS, U.N.O.
2. ALL FOOTINGS MUST BE BOARD-FORMED, UNLESS APPROVED.
3. INCREASE FOOTING DEPTH WHERE REQ'D TO ENCASE COLUMN ANCHOR RODS.
4. FOOTINGS DESIGNED FOR AN ALLOWABLE BEARING CAPACITY OF 7,000 PSF ON GROUND
IMPROVED BY THE USE OF AGGREGATE PIERS, REF. SPECS.
5. 'D' FOOTINGS HAVE INCREASED DEPTH TO RECEIVE 1-1/4" DIAMETER ANCHOR RODS W/ 21"
EMBEDMENT OR TO MAINTAIN MINIMUM FROST PROTECTION.
NOTE: WF STEEL COLUMN SHOWN,
TUBES, PIPES, C.I.P. CONCRETE,
PRECAST & MASONRY COLUMNS SIM.
EQ EQ
LENGTH PER SCHED.EQ EQWIDTH PER SCHED.SEE NOTE #2
SEE NOTE #3
F.F.DEPTHPERSCHED.F3.0 3'-0" 3'-0" 1'-4" (4) #5 x 2'-6"
F4.0 -D 4'-0" 4'-0" 1'-9" (7) #5 x 3'-6"
F5.0 -D 5'-0" 5'-0" 1'-9" (7) #6 x 4'-6"
F6.0 -D 6'-0" 6'-0" 1'-9" (8) #6 x 5'-6"
WALL FOOTING SCHEDULE
FTG.
MARK
FOOTING SIZE FOOTING REINFORCING
WIDTH DEPTH LONGITUDINAL TRANSVERSE
WF24 2'-0" 1'-2" (2) #5 x CONTINUOUS #4 x 1'-6" @ 96" O.C.
WF30 2'-6" 1'-2" (3) #5 x CONTINUOUS #4 x 2'-0" @ 96" O.C.
WF36 3'-0" 1'-4" (3) #5 x CONTINUOUS #4 x 2'-6" @ 96" O.C.
WF42 3'-6" 1'-6" (4) #5 x CONTINUOUS #5 x 3'-0" @ 12" O.C.
WF48 4'-0" 1'-9" (5) #5 x CONTINUOUS #7 x 3'-6" @ 12" O.C.
WF60 5'-0" 1'-9" (5) #6 x CONTINUOUS #7 x 4'-6" @ 12" O.C.
WF72 6'-0" 1'-9" (6) #6 x CONTINUOUS #7 x 5'-6" @ 12" O.C.
WF84 7'-0" 2'-0" (7) #6 x CONTINUOUS #8 x 6'-6" @ 12" O.C.
WF96 8'-0" 2'-0" (9) #6 x CONTINUOUS #8 X 7'-6" @ 12" O.C.
1. CENTER FOOTINGS BENEATH WALLS, U.N.O.
2. REF. SPECIFIC FOUNDATION SECTIONS FOR RETAINING WALL FOOTINGS
(RWF).
3. LAP FOOTING REINFORCING A MINIMUM OF 36 BAR DIAMETERS
4. 'D' FOOTINGS HAVE INCREASE DEPTH TO RECEIVE DEFORMED BAR
ANCHORS (DBA's) W/ 18" EMBEDMENT OR TO MAINTAIN MINIMUM FROST
PROTECTION.
5. 'T' DENOTES ADDITIONAL TOP REINFORCEMENT TO MATCH SCHEDULED
BOTTOM BARS.
WF24-D 2'-0" 1'-9" (3) #5 x CONTINUOUS #4 X 1'-6" @ 96" O.C.
WF30-D 2'-6" 1'-9" (4) #5 x CONTINUOUS #4 X 2'-0" @ 96" O.C.
WF36-D 3'-0" 1'-9" (5) #5 x CONTINUOUS #4 X 2'-6" @ 96" O.C.
WF42-D 3'-6" 1'-9" (6) #5 x CONTINUOUS #4 X 3'-0" @ 96" O.C.
WF48-T 4'-0" 2'-0" (5) #7 x CONTINUOUS #7 X 3'-6" @ 9" O.C.
WF72-T 6'-0" 2'-0" (6) #7 x CONTINUOUS #7 X 5'-6" @ 9" O.C.
WF96-T 8'-0" 2'-0" (9) #7 x CONTINUOUS #7 X 7'-6" @ 9" O.C.
WF84-T 7'-0" 2'-0" (8) #7 x CONTINUOUS #7 X 6'-6" @ 9" O.C.
CAST-IN-PLACE SLAB SCHEDULE
SLAB
MARK
SLAB
"t"
REINFORCING
SUBSTITUTION OF
FIBER FOR W.W.F.
PERMITTED?
SUB-BASE/SUPPORT
CONDITION
4" 6x6-W1.4xW1.4 W.W.F. YES, MICRO 6" MIN. GRANULAR DRAINAGE FILL
& VAPOR BARRIER/RETARDER
5" 6x6-W2.1xW2.1 W.W.F. NO 1 1/2", 18 GA. INVERTED GALV.
STEEL FLOOR DECK
5" 6x6-W2.1xW2.1 W.W.F. YES, MACRO
1. REFER TO CONCRETE SPECIFICATION FOR CONCRETE MATERIALS, PERFORMANCE REQUIREMENTS,
EXECUTION, TESTING, ETC.
3. GRANULAR DRAINAGE FILL TO BE INDOT No. 53 UNLESS APPROVED IN WRITING BY THE STRUCTURAL AND
GEOTECHNICAL TESTING AGENCY.
4. ALL WELDED WIRE FABRIC MUST BE FURNISHED IN SHEETS AND SUPPORTED BY CHAIRS OR CONCRETE
BRICKS TO MAINTAIN SPECIFIED COVERAGES/DEPTHS.
5. LAYOUT CONTROL/CONTRACTION JOINTS AT MAX. SPACING OF 36 x THE SLAB THICKNESS IN FEET (15'-0" FOR 5"
SLAB). LAYOUT TO CONFORM WITH MAJOR COLUMN LINES, HALF-COLUMN LINES, RE-ENTRANT CORNERS
FORMED BY WALLS, ETC. FOR SLABS SCHEDULED TO RECEIVE THIN-SET TERRAZZO, VINYL TILE, SHEET GOODS,
ETC. COORDINATE JOINT LAYOUT WITH THE FINISH FLOOR CONTRACTOR, SUBMIT PROPOSED JOINTING PLAN
FOR REVIEW PRIOR TO CASTING SLAB.
7. DOSAGE RATE OF MICRO-FIBER IS TO BE 1.5 LBS/CU YD.
8. DOSAGE RATE OF MACRO-FIBER IS TO BE 4 LBS/CU YD.
S-A
S-B
S-C
6" MIN. GRANULAR DRAINAGE FILL
5" 6x6-W2.1xW2.1 W.W.F. NO HOLLOW CORE PLANKSS-D
AIR-ENTRAINED
OR INTERIOR
INTERIOR
INTERIOR
AIR-ENTRAINED
INTERIOR
4" YES, MICRO S-E 6" MIN. GRANULAR DRAINAGE FILLAIR-ENTRAINED 6x6-W1.4xW1.4 W.W.F.
CONCRETE PIER SCHEDULE
PIER REINFORCINGPIER
MARK PIER SIZE
VERTICALS TIES-SIZE & SPA. DETAIL CRITICAL HEIGHT
P16 1' -4" 1' -4" (4) #6 #4 @ 10" O.C. A N.A.
P24 2' -0" 2' -0"(8) #6 #4 @ 12" O.C. B ≤2' -8"
(4) #8 #4 @ 12" O.C. A > 2' -8"
P32 2' -8" 2' -8"(12) #6 #4 @ 12" O.C. C ≤2' -8"
(8) #8 #4 @ 12" O.C. B > 2' -8"
P36 3' -0" 3' -0"(12) #7 #4 @ 12" O.C. C ≤3' -0"
(8) #9 #4 @ 12" O.C. B > 3' -0"
1. PROVIDE MIN. 1 ½" CLEAR TO PIER TIES.
2. 'CRITICAL HEIGHT' DENOTES THE HEIGHT ABOVE WHICH LARGER DIAMETER VERTICALS
WITH FEWER TIES MAY BE USED. REF. FOUNDATION PLAN(S) FOR TOP OF PIER & FOOTING
ELEV'S.
3. REF. 'TYPICAL CONCRETE PIER REINFORCING' ON FOUNDATION DETAIL SHEET FOR
FURTHER INFORMATION ON TIE SPACING.
4. VERTICAL DOWELS ARE TO FUNCTION AS PIER VERTICALS FOR PIERS LESS THAN OR EQUAL
TO 5' -0" HIGH. PROVIDE SEPARATE DOWELS & VERTICALS FOR PIERS GREATER THAN OR
EQUAL TO 5' -0" HIGH, UNLESS APPROVED.
5. CONTACT THE STRUCTURAL ENGINEER FOR DIRECTION IF COLUMN ANCHOR RODS FOUL
WITH PIER TIES OR VERTICALS.
6. MIN. HEIGHT OF PIERS: #6 VERTICALS = 2' -0", #7 VERTICALS = 2' -8".
DETAIL "A"
(1) SET
3
(2) SETS
DETAIL "B" DETAIL "C"
(3) SETS(3) SETS
ALT. DETAIL "B"ARCHITECTCLIENT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS ENGINEERTHE SIGNATURECARMELCARMEL, INSTRUCTURAL NOTES& SCHEDULES20010
4/23/2021
PERMIT SET
S002
10/12/21