HomeMy WebLinkAbout_ElevationsELEVATIONSEXTERIOR BUILDINGA601N0. 2SERVICE BUILDING4810 NORTHWESTERN DRIVECARMEL, INDIANA2021 Vision II Design Studioc DO NOT USEFOR CONSTRUCTIONTHESE PLANS ARE CURRENTLY UNDERREVIEW AND ARE SUBJECT TO CHANGE"PRELIMINARY"BUILDING ELEVATION
SCALE : 3/16" = 1'-0"
WEST EXTERIOR
1
BUILDING ELEVATION
SCALE : 3/16" = 1'-0"
SOUTH EXTERIOR
2BUILDING ELEVATION
SCALE : 3/16" = 1'-0"
NORTH EXTERIOR
4
BUILDING ELEVATION
SCALE : 3/16" = 1'-0"
EAST EXTERIOR
3
SPLIT-FACE CMU
(TYP.)
WALL PACK LIGHT FIXTURE
(SEE ELECTRICAL)
PRE-FINISHED METAL
PARAPET CAP
INSULATED STEEL
DOOR & FRAME (TYP.)
INSULATED OVERHEAD
DOOR (TYP.)
6" CONCRETE-FILLED PIPE
BOLLARD (TYP.)
TOP OF SLAB
0'-0"
HIGH
EAVE HEIGHT
+22'-0" (VERIFY)
TOP OF PARAPET
+23'-8" (VERIFY)
TOP OF SLAB
0'-0"
HIGH
EAVE HEIGHT
+22'-0"
TOP OF PARAPET
+25'-6"
TOP OF SLAB
0'-0"
LOW EAVE HEIGHT
+19'-6" (VERIFY)
TOP OF PARAPET
+23'-8" (VERIFY)
TOP OF SLAB
0'-0"
HIGH
EAVE HEIGHT
+22'-0" (VERIFY)
TOP OF PARAPET
+23'-8" (VERIFY)
TOP OF PARAPET
+25'-6"
TOP OF SLAB
0'-0"
HIGH
EAVE HEIGHT
+22'-0" (VERIFY)
TOP OF PARAPET
+23'-8" (VERIFY)
TOP OF PARAPET
+25'-6"
TOP OF SLAB
0'-0"
TOP OF PARAPET
+23'-8" (VERIFY)
TOP OF SLAB
0'-0"
LOW EAVE HEIGHT
+19'-6" (VERIFY)
TOP OF PARAPET
+23'-8" (VERIFY)
EAVE HEIGHT
+19'-6" (VERIFY)
TOP OF SLAB
0'-0"
TOP OF PARAPET
+23'-8" (VERIFY)
LOW EAVE HEIGHT
+19'-6" (VERIFY)
TOP OF PARAPET
+25'-6"
WALL PACK LIGHT FIXTURE
(SEE ELECTRICAL)
SMOOTH-FACE
CMU BAND (TYP.)
METAL WALL PANEL SIDING
(TYP.)METAL WALL PANEL SIDING
(TYP.)
INSULATED STEEL
DOOR & FRAME (TYP.)
ALUMINUM WINDOW
(TYP.)
ARCHITECTURAL WALL PANEL FIBER
CEMENT RAINSCREEN SYSTEM (BY NICHIHA
FIBER CEMENT OR APPROVED EQUAL)
PRE-FINISHED METAL
PARAPET CAP
FABRIC AWNING W/
ALUMINUM FRAME
(TYP.)
WALL SCONCE LIGHT
FIXTURE (SEE
ELECTRICAL)
ALUMINUM
STOREFRONT
WALL PACK LIGHT FIXTURE
(SEE ELECTRICAL)
PRE-FINISHED METAL
PARAPET CAP (BEYOND)
METAL WALL PANEL SIDING
(TYP.)
SPLIT-FACE CMU
(TYP.)
SMOOTH-FACE
CMU BAND (TYP.)
FABRIC AWNING W/
ALUMINUM FRAME
(BEYOND)
WALL SCONCE LIGHT
FIXTURE (BEYOND, SEE
ELECTRICAL)
6" CONCRETE-FILLED
PIPE BOLLARD (TYP.)
PRE-FINISHED METAL
GUTTER AND DOWNSPOUTS,
CONTRACTOR SHALL VERIFY
SIZE REQUIREMENTS (TYP.)
PRE-MANUFACTURED
ROOF ACCESS
LADDER (BEYOND)
PRE-FINISHED METAL
PARAPET CAP
FABRIC AWNING W/
ALUMINUM FRAME
(TYP.)
WALL SCONCE LIGHT
FIXTURE (SEE
ELECTRICAL)
ALUMINUM WINDOW
ARCHITECTURAL WALL PANEL FIBER
CEMENT RAINSCREEN SYSTEM (BY NICHIHA
FIBER CEMENT OR APPROVED EQUAL)
WALL PACK LIGHT FIXTURE
(SEE ELECTRICAL)
METAL WALL PANEL SIDING
(TYP.)
6" CONCRETE-FILLED
PIPE BOLLARD (TYP.)
PRE-FINISHED METAL
GUTTER AND DOWNSPOUTS,
CONTRACTOR SHALL VERIFY
SIZE REQUIREMENTS (TYP.)
PRE-MANUFACTURED
ROOF ACCESS
LADDER (BEYOND)
ALUMINUM STOREFRONT
PRE-FINISHED METAL
PARAPET CAP
PRE-FINISHED METAL
PARAPET CAP
INSULATED OVERHEAD
DOOR (TYP.)9'-0"3'-0"9'-0"3'-0"3'-0" 3'-0"9'-0"3'-0"3'-0"6'-0"6'-0"6'-0"6'-0"4'-0"4'-0"WALL PACK LIGHT FIXTURE
(SEE ELECTRICAL)
METAL WALL PANEL SIDING
(TYP.)
PRE-FINISHED METAL
PARAPET CAP (BEYOND)
PRE-FINISHED METAL GUTTER AND
DOWNSPOUTS, CONTRACTOR
SHALL VERIFY SIZE REQUIREMENTS
(TYP.)
PRE-FINISHED METAL
PARAPET CAP
PRE-FINISHED METAL
PARAPET CAP (BEYOND)
SPLIT-FACE CMU
(TYP.)
SMOOTH-FACE
CMU BAND (TYP.)
SPLIT-FACE CMU
(TYP.)
SMOOTH-FACE
CMU BAND (TYP.)
FABRIC AWNING W/
ALUMINUM FRAME
(BEYOND)
WALL SCONCE
LIGHT FIXTURE (
BEYOND, SEE
ELECTRICAL)
3'-0"
PRE-MANUFACTURED
ROOF ACCESS
LADDER (BEYOND)
STANDING-SEAM METAL
ROOF SYSTEM
12
0.5 12
0.5
DASHED LINE REPRESENTS
PROFILE OF ROOF BEHIND
PARAPET
DASHED LINE REPRESENTS
PROFILE OF ROOF BEHIND
PARAPET
SPLIT-FACE CMU
(TYP.)
SMOOTH-FACE
CMU BAND (TYP.)
WALL PACK LIGHT FIXTURE
(SEE ELECTRICAL)
ROOFTOP EQUIPMENT SCREEN W/
CORRUGATED METAL PANELS
ATTACHED (RTU-MOUNTED)
ROOFTOP EQUIPMENT SCREEN W/
CORRUGATED METAL PANELS
ATTACHED (RTU-MOUNTED)
ROOFTOP EQUIPMENT SCREEN W/
CORRUGATED METAL PANELS
ATTACHED (RTU-MOUNTED)
ROOFTOP EQUIPMENT SCREEN W/
CORRUGATED METAL PANELS
ATTACHED (RTU-MOUNTED)
ROOFTOP EQUIPMENT SCREEN W/
CORRUGATED METAL PANELS
ATTACHED (RTU-MOUNTED)
ROOFTOP EQUIPMENT SCREEN W/
CORRUGATED METAL PANELS
ATTACHED (RTU-MOUNTED)
ROOFTOP EQUIPMENT SCREEN W/
CORRUGATED METAL PANELS
ATTACHED (RTU-MOUNTED)
WALL SCONCE LIGHT FIXTURE
(SEE ELECTRICAL)
03/16/22