15117_-_A023_-_Interior_Wall_Assemblies
NOMINAL 8" OR 10" CMU WALL.SEE STRUCTURAL DWGSFOR GROUT & REINFORCING.WB17 5/8"USE: CMU BLOCK WALLSUL DESIGNATION: U9052-HOUR RATEDWS4USE: MECHANICAL CHASES AND STAIR WALLS(2) LAYER 5/8" GYPSUM WALLBOARD TYPE 'X' ONE SIDE2 1/2" STEEL 'J' RUNNERFIRE SEALANT(1) LAYER 1" GYPSUM WALLBOARD LINER PANELFIRE SEALANT3 3/4"2 1/2" STEEL 'J' RUNNERNON-SHAFT SIDESHAFT SIDENON-SHAFT SIDESHAFT SIDE2 1/2" C-H STEEL STUD1'-4"1'-4"UL DESIGNATION: U4152-HOUR RATEDWS1USE: TYPICAL INTERIOR METAL STUDWALL, NON-RATED1'-4"(1) LAYER 5/8" GYPSUMWALL BOARD TYPE 'X'20 GAUGE METAL STUDS,16" O.C.1'-4"1'-4"1'-4""WS1A" - 3-5/8" METAL STUDS"WS1AI" - 3 58" METAL STUDS W/ INSUL"WS1B" - 6" METAL STUDS"WS1BI" - 6" METAL STUDS W/ INSULWS2"WS2A" - 3-5/8" METAL STUDS"WS2AI" - 3 58" METAL STUDS W/ INSUL"WS2B" - 6" METAL STUDS"WS2BI" - 6" METAL STUDS W/ INSULWS1BWS1AUL DESIGNATION: U4231-HOUR RATEDWS31'-4"1'-4"1'-4"1'-4"WS2BWS2AUSE: TYPICAL INTERIOR METAL STUDWALL, FIRE RATEDUSE: TYPICAL INTERIOR METAL STUD FURRING WALL"WS3A" - 2-1/2" METAL STUDS"WS3AI" - 2-1/2" METAL STUDS W/ KRAFT-FACED BATT INSULATION"WS3B" - 3-5/8" METAL STUDS"WS3BI" - 3-5/8" METAL STUDS W/ KRAFT-FACED BATT INSULATION"WS3C" - 6" METAL STUDS"WS3CI" - 6" METAL STUDS W/ KRAFT-FACED BATT INSULATION(1) LAYER 5/8" GYPSUMWALL BOARD TYPE 'X'20 GAUGE METAL STUDS,16" O.C.1'-4"1'-4"1'-4"1'-4"WS3CWS3B(1) LAYER 5/8" GYPSUMWALL BOARD TYPE 'X'20 GAUGE METAL STUDS,16" O.C.WS3BI"WB1A" - 7 5/8" CMU BLOCK"WB1B" - 9 5/8" CMU BLOCK9 5/8" 3 5/8"6" 6"3 5/8" 3 5/8"6"1'-4"1'-4"WS3AWS3AI2 1/2"WS2AIWS51'-4"1'-4"USE: BULLETPROOF WALL(1) LAYER 5/8" GYPSUMWALL BOARD TYPE 'X'12" BULLETPROOF SHEATHINGTO ACHIEVE NIJ LEVEL 3 RATING(4" ABOVE CEILING)6"1'-4"1'-4"(1) LAYER 5/8" GYPSUMWALL BOARD TYPE 'X'20 GAUGE METAL STUDS,16" O.C.3 5/8"20 GAUGE METAL STUDS,16" O.C.SOUND ATTENUATION INSULATIONTREATED FIRE RATEDWOOD SHEATHINGWS6USE: IDF ROOMSINTERIOR IDF ROOMINTERIOR IDF ROOMTOP OF WALLS TO DECKDEEP LEG DEFLECTIONTRACK AT TOP OF WALLNOMINAL 4" CMU WALL.SEE STRUCTURAL DWGSFOR GROUT & REINFORCING.WB23 5/8"USE: CMU BLOCK WALLSUL DESIGNATION: U9052-HOUR RATED4"ADDITIONAL WALL FINISH ON ONE ORBOTH SIDES WHERE OCCURS; REFERTO FLOOR PLANS AND ROOM FINISHSCHEDULE FOR OCCURENCE,LOCATION, AND EXTENT OF WALLCOVERAGE. TYPICALSEALANT AND BACKER ROD;BOTH SIDES, CONT.SEALANT AND BACKER ROD;BOTH SIDES, CONT.METAL TRACKMETAL DEFLECTION TRACKCEILING LINE58" CHIPBOARDWS1BIWS1AIWS2BIWS3CIA023Interior Wall Assemblies ARCHITECTPROJECTDRAWING TITLESEALSHEETPROJECT INFO REVISIONS15117 Carmel Police Station Addition CLIENT/CM#DESCRIPTIONDATEDecember 17, 2021Construction Documents3 Civic Square Carmel, IN 46032