HomeMy WebLinkAbout15117_-_A201A_-_ENLARGED_FIRST_FLOOR_PLAN_-_AREA_AA302 3
Men's
RR
180
Women's
RR
179
Stair
ST-4
Operations
Lieutenant
176
Operations
Major
175
Lieutenant
174
Major
173
Chief's Office
171
RR
170
Assistant Chief
169
Chief's Secretary
172
Conference
168
Elec.
178
Personnel Storage
167
Storage
160
Coffee
177
Reception
166
Elevator
EL
Drug Task Force
157
Mech.
161
Storage
156
DTF Entry
154
Mech.
155
DTF Lieutenant
159
DTF Sergeants
158
Intel Sergeant
143
Intel Unit
141
IDF
144 Intel Storage
142
Investigations
Sergeant
147
Investigations
Sergeant
148
Investigations
Lieutenant
149
Storage
150
Mech./Elec.
151
Investigations
Conference
146
Investigations
152
Stair
ST-5
Stair
ST-3
175176ST-4168B169168A172167160157161144146141158159143146AST-3.B178
174
173
171
171A 169A170 156
155154 142
147
148
149
150
151 152
Deputy Chief
of Operations
165
Chaplain
164
Investigations
Prosecutor
163
Investigations
Divisions Commander
162
164163162139A
8
G
EF
D
C
B
A
H
J
K
L
9 10 11 127654321
136' - 0"
142400-1
Investigations
Sergeant
153
Corridor
145
153
A302
2
A302
1
8' - 4 5/8"WS1A
WS1AI
WS1AIWS1AIWS1AIWS6
WS1A
WS1AWS1AWS1A
WS1AI
WS1AIWS1AIWS1AIWS1AIWS1AWS1AWS1A WS1AIWS1A46' - 7 1/4"
12' - 2 5/16" 11' - 3 1/16" 11' - 6 1/2"11' - 7 3/8"
5' - 7 5/8" 6' - 6 11/16" 8' - 1 5/16" 3' - 1 3/4" 2' - 10 1/4" 8' - 8 1/4" 5' - 11 3/4" 5' - 7 5/8"165WS3B WS3BWS3BWS3BWM2 3' - 8 1/2" 3' - 0" 16' - 1 3/4"22' - 4 7/8"2' - 10 1/2" 3' - 0" 16' - 1 3/4"
1' - 0" 4' - 4" R.O. 10' - 1 3/8"
0' - 10 7/16"
4' - 4" R.O. 10' - 5 1/2"
0' - 8"7' - 10 3/4" 4' - 4" R.O.
0' - 6"
44' - 6"
15' - 5 3/8"15' - 7 7/8"13' - 4 3/4"
22' - 10 3/16"
3' - 0"
2' - 9 3/4"
9' - 0 1/8" 6' - 2 1/2"10' - 8 1/2"17' - 11"WS6 WS6WS6See
A201B
2
WX WX WX WX
WS1B
2 2 2
2
2
2
2
2
2
2
2
22 2 2
2
22
2
2
2
2
WS3AI
W7
W7
4' - 3 1/8"13' - 2 1/4"0' - 8 1/2"
2' - 2 3/4"
1616
25
3
ID203
WS3CI16
16
052400-1WS3CIWS3CI WS3CI16
16
141A
0' - 7 3/8"
WS3A
WS3A
22
16
22
16
5' - 7 1/2"WS1A10' - 0"16
22
16
WS3B
1' - 3 5/8"
22
15' - 0 1/4" 1' - 6"2' - 2 1/4"3' - 1 3/4"4' - 0"WS3BWS3B
WS3A
WS3A2' - 1 3/8"3' - 5" 4' - 5"
22
22
22
WS3AWS3A3' - 5 1/2"3' - 5 1/2"179 180
2' - 8 1/8"2' - 8"2' - 8 1/8"1' - 1 1/8"
WS3A WS3A
16
6" metal bollard
TV. See Electrical and Technology drawings
for power and data requirements. Provide
blocking as required.
Existing fire panel
Mechanical louvers. See MEP drawings for
additional information.
Motorcycle dual port EV chargers
Fingerprint station
Security checkpoint
Electronic forms
36" x 48" automatic wheelchair lift. See
Electrical drawings for power requirements.
Limestone panel. See elevations.
Recessed green screen. Coordinate with
electrical.
Interior metal window grill
Built-in holding cell bench
Provide Binder KBF-S Solid Line Series
Humidity Test Chamber (102L, Stainless
Steel), evidence refrigerator, existing
safes, and stainless steel table.
Painted parking stripes
Align finish face
Mop sink
Existing walls to recieve FRTW sheathing on
top of existing finish layer
Floor drain
Turnstile
New concrete slab on grade infill. Extents
as required in coordination with demolition
and repair of underslab plumbing
Wall infill to match adjacent wall
construction; Align finish faces
Warp concrete to achieve drainage around
column
Decorative exterior railing
Apply privacy film to existing window glazing
See Structural Sheets for structural
reinforcement needed to support
mobile shelving above.
PLAN NOTES
1
2
3
4
5
6
7
8
9
10
11
12
13
* Reference ID300 Reflected Ceiling Plan
Sheets for walls to deck
14
15
16
17
18
19
20
21
22
23
24
25
26
PLAN SPEC KEYNOTES
1. THE GENERAL CONTRACTOR SHALL VERIFY
ALL CONDITIONS AT THE JOBSITE. NOTIFY
ARCHITECT OF ANY DEVIATIONS FROM THOSE
CONDITIONS AS THEY ARE NOTED ON THE
DRAWINGS.
2. THE GENERAL CONTRACTOR SHALL
COORDINATE AND SCHEDULE ALL WORK WITH
THE OWNER.
3. THE GENERAL CONTRACTOR IS
RESPONSIBLE FOR COMPLIANCE WITH ALL
STATE AND LOCAL BUILDING CODES AND
GOVERNMENT REGULATORY AGENCIES.
4. THE GENERAL CONTRACTOR IS TO SUBMIT
SHOP DRAWINGS-PROJECT DATA AND
SAMPLES TO OWNER/ARCHITECT FOR
APPROVAL PRIOR TO FABRICATION OF ALL
MILLWORK AND WALL FINISHES.
5. DO NOT SCALE ANY DRAWING. ANY
DIMENSIONS ARE TO BE OBTAINED FROM THE
ARCHITECT IF NOT NOTED ON THE DRAWINGS.
REFER ALL QUESTIONS TO THE ARCHITECT OR
ENGINEER ON RECORD.
6. ALL DIMENSIONS ARE TO FACE OF FRAMING
U.N.O.
7. THE GENERAL CONTRACTOR SHALL KEEP
ONE SET OF PLANS AT THE JOBSITE FOR THE
SPECIFIC PURPOSE OF RECORDING ACTUAL
CONSTRUCTION CONDITIONS. SUCH PROJECT
RECORD-DOCUMENTS SHALL BE PROVIDED TO
THE OWNER UPON COMPLETION OF THE
PROJECT.
8. THE GENERAL CONTRACTOR SHALL VERIFY
SIZE, LOCATION, AND CHARACTERISTICS OF
ALL WORKS AND EQUIPMENT SUPPLIED BY THE
OWNER OR OTHERS WITH THE MANUFACTURER
OR SUPPLIER PRIOR TO THE START OF THE
WORK.
9. THE GENERAL CONTRACTOR SHALL SEE
THAT ALL SUBCONTRACTORS RECEIVE
COMPLETE WORKING DRAWINGS AND ASSUME
FULL RESPONSIBILITY FOR COORDINATION OF
WORK.
10. SEE ID SHEETS FOR CABINETRY AND
CASEWORK INFORMATION.
GENERAL NOTES
ARCHITECTCLIENT/CMPROJECTDRAWING TITLESEALSHEETPROJECT INFOREVISIONS15117
December 17, 2021
Construction Documents
A201AENLARGED FIRSTFLOOR PLAN - AREA ACARMEL POLICE STATIONADDITIONSCALE: 1/8" = 1'-0"1 Enlarged First Floor - Area A
#DESCRIPTION DATE
Area A
Area B
Key Plan