HomeMy WebLinkAbout15117_-_A202A_-_ENLARGED_SECOND_FLOOR_PLAN_-_AREA_AA302 3
Electrical
251
Corridor
250
Mechanical
252
Office
248
Mechanical
249
Storage
247
IT Storage
246
Elevator
EL
IDF
235
Storage
236
Evidence
237
Secured Evidence
238
Storage
240
Office
241
Storage
242
Mechanical
244
Mech./Elec.
243
Stair
ST-3
Stair
ST-4
252 250
249
245
235
238
244
242
241
ST-3
248246236237239A2402438
G
EF
D
C
B
A
H
J
K
L
9 10 11 127654321
142400-1
Corridor
234
Corridor
245
A302
2
A302
1
WS1AWS1A
10' - 1 7/8"13' - 3" 2' - 0 3/4"21' - 8 7/8"15' - 4 7/8"11' - 3 5/8"WS1A3' - 0"13' - 9 1/8"WS6
WS6
5' - 7 1/4"2' - 0 3/8"WS66' - 0" 8' - 11 3/8"8' - 0 3/8"WS1AST-4WS6See
A202B
14 2392
2
2
Evidence Storage
239
17' - 5 5/8"
SLOPE SLOPE
22
22
22
26
6" metal bollard
TV. See Electrical and Technology drawings
for power and data requirements. Provide
blocking as required.
Existing fire panel
Mechanical louvers. See MEP drawings for
additional information.
Motorcycle dual port EV chargers
Fingerprint station
Security checkpoint
Electronic forms
36" x 48" automatic wheelchair lift. See
Electrical drawings for power requirements.
Limestone panel. See elevations.
Recessed green screen. Coordinate with
electrical.
Interior metal window grill
Built-in holding cell bench
Provide Binder KBF-S Solid Line Series
Humidity Test Chamber (102L, Stainless
Steel), evidence refrigerator, existing
safes, and stainless steel table.
Painted parking stripes
Align finish face
Mop sink
Existing walls to recieve FRTW sheathing on
top of existing finish layer
Floor drain
Turnstile
New concrete slab on grade infill. Extents
as required in coordination with demolition
and repair of underslab plumbing
Wall infill to match adjacent wall
construction; Align finish faces
Warp concrete to achieve drainage around
column
Decorative exterior railing
Apply privacy film to existing window glazing
See Structural Sheets for structural
reinforcement needed to support
mobile shelving above.
PLAN NOTES
1
2
3
4
5
6
7
8
9
10
11
12
13
* Reference ID300 Reflected Ceiling Plan
Sheets for walls to deck
14
15
16
17
18
19
20
21
22
23
24
25
26
PLAN SPEC KEYNOTES
1. THE GENERAL CONTRACTOR SHALL VERIFY
ALL CONDITIONS AT THE JOBSITE. NOTIFY
ARCHITECT OF ANY DEVIATIONS FROM THOSE
CONDITIONS AS THEY ARE NOTED ON THE
DRAWINGS.
2. THE GENERAL CONTRACTOR SHALL
COORDINATE AND SCHEDULE ALL WORK WITH
THE OWNER.
3. THE GENERAL CONTRACTOR IS
RESPONSIBLE FOR COMPLIANCE WITH ALL
STATE AND LOCAL BUILDING CODES AND
GOVERNMENT REGULATORY AGENCIES.
4. THE GENERAL CONTRACTOR IS TO SUBMIT
SHOP DRAWINGS-PROJECT DATA AND
SAMPLES TO OWNER/ARCHITECT FOR
APPROVAL PRIOR TO FABRICATION OF ALL
MILLWORK AND WALL FINISHES.
5. DO NOT SCALE ANY DRAWING. ANY
DIMENSIONS ARE TO BE OBTAINED FROM THE
ARCHITECT IF NOT NOTED ON THE DRAWINGS.
REFER ALL QUESTIONS TO THE ARCHITECT OR
ENGINEER ON RECORD.
6. ALL DIMENSIONS ARE TO FACE OF FRAMING
U.N.O.
7. THE GENERAL CONTRACTOR SHALL KEEP
ONE SET OF PLANS AT THE JOBSITE FOR THE
SPECIFIC PURPOSE OF RECORDING ACTUAL
CONSTRUCTION CONDITIONS. SUCH PROJECT
RECORD-DOCUMENTS SHALL BE PROVIDED TO
THE OWNER UPON COMPLETION OF THE
PROJECT.
8. THE GENERAL CONTRACTOR SHALL VERIFY
SIZE, LOCATION, AND CHARACTERISTICS OF
ALL WORKS AND EQUIPMENT SUPPLIED BY THE
OWNER OR OTHERS WITH THE MANUFACTURER
OR SUPPLIER PRIOR TO THE START OF THE
WORK.
9. THE GENERAL CONTRACTOR SHALL SEE
THAT ALL SUBCONTRACTORS RECEIVE
COMPLETE WORKING DRAWINGS AND ASSUME
FULL RESPONSIBILITY FOR COORDINATION OF
WORK.
10. SEE ID SHEETS FOR CABINETRY AND
CASEWORK INFORMATION.
GENERAL NOTES
ARCHITECTCLIENT/CMPROJECTDRAWING TITLESEALSHEETPROJECT INFOREVISIONS15117
December 17, 2021
Construction Documents
A202AENLARGED SECONDFLOOR PLAN - AREA ACARMEL POLICE STATIONADDITIONSCALE: 1/8" = 1'-0"1 Enlarged Second Floor Plan - Area A
#DESCRIPTION DATE
Area A
Area B
Key Plan