HomeMy WebLinkAbout15117_-_A203_-_ENLARGED_MEZZANINE_FLOOR_PLANUP
UP
A3001
13 14 15 16 17 18 19
M
N
P
Q
R
S
T
U
G
F
D
C
B
A
H
J
K
L
12
Q7
Q.1
Q.3
Q.5
Q.9
P.2
R.3
18.7
M.1
15.2 15.4 15.6 15.8
T.8
M.3
T.6
A301
1
A300
2
4
A453
4
A454ST-1.4ST-2.4WS3CIWS3CIWS3CIWS3CIWS3CI WS3CI
WS3CIWS3CIWS3CIWS3CI
Stair
ST-2
Stair
ST-1
6" metal bollard
TV. See Electrical and Technology drawings
for power and data requirements. Provide
blocking as required.
Existing fire panel
Mechanical louvers. See MEP drawings for
additional information.
Motorcycle dual port EV chargers
Fingerprint station
Security checkpoint
Electronic forms
36" x 48" automatic wheelchair lift. See
Electrical drawings for power requirements.
Limestone panel. See elevations.
Recessed green screen. Coordinate with
electrical.
Interior metal window grill
Built-in holding cell bench
Provide Binder KBF-S Solid Line Series
Humidity Test Chamber (102L, Stainless
Steel), evidence refrigerator, existing
safes, and stainless steel table.
Painted parking stripes
Align finish face
Mop sink
Existing walls to recieve FRTW sheathing on
top of existing finish layer
Floor drain
Turnstile
New concrete slab on grade infill. Extents
as required in coordination with demolition
and repair of underslab plumbing
Wall infill to match adjacent wall
construction; Align finish faces
Warp concrete to achieve drainage around
column
Decorative exterior railing
Apply privacy film to existing window glazing
See Structural Sheets for structural
reinforcement needed to support
mobile shelving above.
PLAN NOTES
1
2
3
4
5
6
7
8
9
10
11
12
13
* Reference ID300 Reflected Ceiling Plan
Sheets for walls to deck
14
15
16
17
18
19
20
21
22
23
24
25
26
1. THE GENERAL CONTRACTOR SHALL VERIFY
ALL CONDITIONS AT THE JOBSITE. NOTIFY
ARCHITECT OF ANY DEVIATIONS FROM THOSE
CONDITIONS AS THEY ARE NOTED ON THE
DRAWINGS.
2. THE GENERAL CONTRACTOR SHALL
COORDINATE AND SCHEDULE ALL WORK WITH
THE OWNER.
3. THE GENERAL CONTRACTOR IS
RESPONSIBLE FOR COMPLIANCE WITH ALL
STATE AND LOCAL BUILDING CODES AND
GOVERNMENT REGULATORY AGENCIES.
4. THE GENERAL CONTRACTOR IS TO SUBMIT
SHOP DRAWINGS-PROJECT DATA AND
SAMPLES TO OWNER/ARCHITECT FOR
APPROVAL PRIOR TO FABRICATION OF ALL
MILLWORK AND WALL FINISHES.
5. DO NOT SCALE ANY DRAWING. ANY
DIMENSIONS ARE TO BE OBTAINED FROM THE
ARCHITECT IF NOT NOTED ON THE DRAWINGS.
REFER ALL QUESTIONS TO THE ARCHITECT OR
ENGINEER ON RECORD.
6. ALL DIMENSIONS ARE TO FACE OF FRAMING
U.N.O.
7. THE GENERAL CONTRACTOR SHALL KEEP
ONE SET OF PLANS AT THE JOBSITE FOR THE
SPECIFIC PURPOSE OF RECORDING ACTUAL
CONSTRUCTION CONDITIONS. SUCH PROJECT
RECORD-DOCUMENTS SHALL BE PROVIDED TO
THE OWNER UPON COMPLETION OF THE
PROJECT.
8. THE GENERAL CONTRACTOR SHALL VERIFY
SIZE, LOCATION, AND CHARACTERISTICS OF
ALL WORKS AND EQUIPMENT SUPPLIED BY THE
OWNER OR OTHERS WITH THE MANUFACTURER
OR SUPPLIER PRIOR TO THE START OF THE
WORK.
9. THE GENERAL CONTRACTOR SHALL SEE
THAT ALL SUBCONTRACTORS RECEIVE
COMPLETE WORKING DRAWINGS AND ASSUME
FULL RESPONSIBILITY FOR COORDINATION OF
WORK.
10. SEE ID SHEETS FOR CABINETRY AND
CASEWORK INFORMATION.
GENERAL NOTES
PLAN SPEC KEYNOTES ARCHITECTCLIENT/CMPROJECTDRAWING TITLESEALSHEETPROJECT INFOREVISIONS15117
December 17, 2021
Construction Documents
A203ENLARGED MEZZANINEFLOOR PLANCARMEL POLICE STATIONADDITIONSCALE: 1/8" = 1'-0"1 Enlarged Mechanical Mezzanine Plan
#DESCRIPTION DATE
Area A
Area B
Key Plan