HomeMy WebLinkAbout42230025 - GR2 79 - Floor LayoutLayout Name 79 Gramercy Description 9801-C Created June 24, 2019 Revised October 22, 2021 Builder David Weekley Homes Sales Rep Jeremiah Maeda Designer Juan Varela Contract Lumber 200 Schofield Drive Columbus , OH 43213 614.751.1109 2nd Flr. I Joist Label Description Width Depth Qty Plies Pcs Length F1 LPI 20Plus 2.5 14 1 3-9-12 F8 LPI 20Plus 2.5 14 1 2 2 24-5-4 F12 LPI 20Plus 2.5 14 1 2 2 18-11-0 J1 LPI 20Plus 2.5 14 1 9-5-2 J3 LPI 20Plus 2.5 14 2 18-7-4 J4 LPI 20Plus 2.5 14 6 21-11-4 J5 LPI 20Plus 2.5 14 7 24-5-4 J6 LPI 20Plus 2.5 14 3 3-9-12 J8 LPI 20Plus 2.5 14 2 22-0-6 J14 LPI 20Plus 2.5 14 6 9-5-2 J15 LPI 20Plus 2.5 14 3 4-8-4 J15 LPI 20Plus 2.5 14 5 4-8-2 J15 LPI 20Plus 2.5 14 1 4-8-0 J16 LPI 20Plus 2.5 14 1 18-11-0 J17 LPI 20Plus 2.5 14 4 18-8-14 J18 LPI 20Plus 2.5 14 1 22-8-8 J19 LPI 20Plus 2.5 14 1 24-6-6 LVL/LSL Label Description Width Depth Qty Plies Pcs Length D3 LP-LSL 1.75E 1.75 9.25 1 4-0-0 F2 LP-LSL 1.75E 1.75 14 1 2 2 12-0-0 F3 LP-LSL 1.75E 1.75 14 1 10-0-0 F4 LP-LSL 1.75E 1.75 14 1 5-0-0 F5 LP-LSL 1.75E 1.75 14 1 3 3 15-0-0 F11 LP-LSL 1.75E 1.75 14 1 8-0-0 D2 LP-LVL 2900Fb-2.0E 1.75 16 1 2 2 22-0-0 Rim Board Label Description Width Depth Qty Plies Pcs Length R1 LP APA Rated OSB 1.125 X 14 1.125 14 14 12-0-0 Lumber Label Description Width Depth Qty Plies Pcs Length D1 SP #2 1.5 5.5 8 4-0-0 D5 SP #2 1.5 7.25 2 4-0-0 F9 SP #2 1.5 7.25 1 2 2 8-0-0 F10 SP #2 1.5 7.25 1 2 2 10-0-0 J2 SP #2 1.5 7.25 5 8-0-0 Hanger Beam/Girder Supported Member Label Pcs Description Skew Slope fasteners fasteners H2 21 IHFL2514 (Min) 12 10d H4 2 THF25112-2 16 10dx1 1/2 6 10d H5 9 IHF2514 (Min) 12 10d 2 10dx1 1/2 2nd Flr. Design Method ASD (USA) Building Code IBC 2018 Floor Loads Live 40 Dead 10 Deflection Joist LL Span L/ 480 TL Span L/ 240 LL Cant 2L/ 480 TL Cant 2L/ 240 Deflection Girder LL Span L/ 480 TL Span L/ 240 LL Cant 2L/ 480 TL Cant 2L/ 240 Decking Decking OSB 23/32 APA Rated Sturd- I-Floor Fastener Nailed & Glued 24" O.C. START LAYOUT SE EMPIEZA AQUI HOLD OFF 12" 10" HOLE CHASE 16" O.C. CHANGE LAYOUT SE EMPIEZA AQUI 10" HOLE CHASE 10" HOLE CHASE 10" HOLE CHASE 10" HOLE CHASE 3 3 E1N E1N 3 JACKS REQ. THIS END A3 A3 A7 A7 2 X J6 J17 - @ 24" 2 X J3 J14 - @ 24" J4 - @ 16" 2 X J8 J5 - @ 16" F2 ( 2 ply ) F9 ( 2 ply ) F5 ( 3 ply ) D2 ( 2 ply ) D1 ( 1 ply ) D1 ( 1 ply ) D1 ( 1 ply ) D1 ( 1 ply ) D5 ( 1 ply ) D5 ( 1 ply ) H2 H4 H2 H2 H2 General Notes - It is the sole responsibility of the builder/installer to follow this layout exactly. Notify Contract Lumber of any discrepancies between this layout and field conditions. Contract Lumber is not liable for any field changes without prior approval. - Refer to details in the installation guide prior to construction GIRDER TRUSS DB1 ( 2 ply ) D4 ( 2 ply ) D1 ( 1 ply ) D1 ( 1 ply ) D1 ( 1 ply ) D1 ( 1 ply ) D1 ( 1 ply ) D1 ( 1 ply ) Roof Lumber Label Description Width Depth Qty Plies Pcs Length D1 SP #2 1.5 5.5 14 4-0-0 D4 SP #2 1.5 5.5 1 2 2 4-0-0 DB2 SP #2 1.5 9.25 1 2 2 10-0-0 DB1 SP #2 1.5 9.25 1 2 2 8-0-0 Version 20.60.158 Powered by iStruct This layout is to be used as an installation guide only. It is meant to be used in conjunction with the architectural and structural drawings, not to replace them