HomeMy WebLinkAboutCorrespondence8000 Avalon Blvd
Alpharetta, GA 30009
Phone: (678) 618 -8418
Email:
Tonya.Langley.Contractor@crowncas
tle.com
www.crowncastle.com
587999 - CROWN CASTLE TDC
August 24, 2022
VIA email CONSENT
Dale.Brooks@duke-energy.com
PSI ENERGY INC
526 S CHURCH ST MAILCODE: EC05DQ
ATTN: LEASE ADMIN
CHARLOTTE, NC 28202
Re: BU 873711 / “Carmel-Springmill” / 1531 W Main St, Carmel, IN 46032 (“Site”)
Master Land Lease And Development Rights Agreement , dated March 1, 1999, as it may have been amended and
assigned (“Lease”), Consent for modifications, Crown BU: 873711, Duke Site Name: Carmel Springmill Rd SubStation
Dear Mr. Brooks,
In order to better serve the public and minimize the amount of towers in an area where this property is located, CROWN CASTLE
TDC intends to modify its equipment at the wireless communication facility (the “Modification”).
Under the Lease, Landlord’s consent cannot be unreasonably withheld, conditioned or delayed. Please provide your consent
on or before August 24, 2022 by signing below and returning to Tonya.Langley.Contractor@crowncastle.com so that we
may install CROWN CASTLE TDC’s equipment as permitted under the Lease.
Crown SOW: Drop and Swap Project: Crown to remove existing 124’ monopole and replace it with a new 150’ monopole.
CROWN will not start CONSTRUCTION until an approved Construction Start Date is Received From Duke
Energy Indiana, LLC. CDS will also need to be signed and approved. A Notice to Proceed will be signed by
Duke Energy Indiana LLC and Crown Castle and the signing of this letter only confirms the acknowledgment
of Crown Castle TDC’s removing the existing 124’ monopole and installing a new 150’ monopole (as requested
by the jurisdiction’s Technical Advisory Committee).
Please see the enclosed supplemental materials, as may be required by the Lease. If you have any questions concerning
this request, please contact Tonya Langley at (678) 618-8418 or Tonya.Langley.Contractor@crowncastle.com
Sincerely,
Tonya Langley
Tonya Langley
Real Estate Specialist
Agreed and accepted aate]_________ ___________
(Date)
(Lessor’s signature)
(Lessor’s name and title)
[Enclosures]
Dale Brooks, Transaction Manager
A
08/24/2022
Latitude:
Longitude:
Ground Elevation:
Respectfully,
GPD Group, Inc.
Steven L. Mullaney, LS21100013
T:\Crown\873711\05 A&E\4_AE\09_Other Services\Carmel-Springhill_873711_1A Letter.pdf
NAD 1983
Crown Castle
873711
Carmel-Springhill
Hamilton County
We have determined the following information regarding new tower location for
the above referenced cell site:
NAVD 1988
We represent that the coordinates provided are accurate within FAA Horizontal
Accuracy Code 1, +/- 20 feet and the elevations provided are accurate within
FAA Vertical Accuracy Code A, +/- 3 feet.
39° 58' 37.12" N
86° 10' 10.81" W
862.6'
520 South Main Street, Suite 2531 | Akron, OH 44311 | 330.572.2100 | gpdgroup.com
03/11/22
520 South Main Street, Suite 2531 | Akron, OH 44311 | 330.572.2100 | gpdgroup.com
March 11, 2022
PLACE GOOGLE EARTH SNIP IT HERE
Architects Engineers'Planners
www.gpdgroup.com
G P D GROUP' 1-800-955-4731
LETTER OF TRANSMITTAL
Attention Lisa Motz Date 03/24/22 Job No 873711
To City of Carmel Re Crown Castle: 873711 Carmel-Springmill
One Civic Square 1531 W. Main St.
Carmel, IN 46032 Carmel, IN 46032
(317) 571-2417
WE ARE SENDING YOU
® Attached ❑ Under separate cover via the following items:
❑ Shop drawings ❑ Prints ❑ Plans ❑ Samples ❑ Specifications
❑ Copy of letter ❑ Change order ❑ Sepias ❑
COPIES DATE NO. DESCRIPTION
1 03/24/22 1 Check #136230 for $389.00
THESE ARE TRANSMITTED as checked below:
❑ For compliance ❑ No Exception Noted ❑ Submit copies for distribution
Exceptions Noted (do
❑ For your use ❑ not resubmit) ❑ Return _corrected documents
Revise & resubmit (see
❑ As requested ❑ Notes) ❑ PRINTS RETURNED AFTER LOAN TO US
❑ For review and comment ❑ Rejected ❑
Not Required — Return
❑ without Action
❑ FOR BIDS DUE 20_
REMARKS:
Please see enclosed check for docket #PZ-2022-00047.
If you have any questions, please let us know. Contact # 234-231-7960, mbeddow@gpdgroup.com
Copy to File Signed Mike Beddow
If enclosures are not as noted,kindly notify us at once.
5/27/22
Carmel Zoning & Planning
City Hall
One Civic Square
Carmel, IN 46032
RE: PZ-2022-00047 TAC – BU#873711 – Carmel Springmill
To Whom It May Concern,
Crown Castle acknowledges and agrees to comply with the Carmel UDO – Section 5.78.G – Removal as stated
below.
“If a Wireless Support Structure is abandoned or remains unused for a period of six (6) months, the owner shall
remove the Wireless Support Structure and all associated facilities from the site. Such removal shall be completed
within twelve (12 months of the cessation of operations at the site. In the event that a Wireless Support Structure is
not removed within the required twelve (12 month period, the Director of Community Services may remove the
Wireless Support Structure and the associated facilities, and the costs of such removal shall be assessed against the
owner of the parcel.”
Sincerely,
Sarah Brown
Crown Castle
NTC PM
May 2022
Marion County IN Zoning Plots; Site Name: GN 131St And Sheffield
To Whom It May Concern:
This map is not a guarantee of coverage and may contain areas with no service.This map reflects a
depiction of predicted and approximate wireless coverage of the network and is intended to provide a
relative comparison of coverage.The depictions of coverage do not guarantee service availability as
there are many factors that can influence coverage and service availability.These factors vary from
location to location and change over time.The coverage areas may include locations with limited or
no coverage.Even within a coverage area shown,there are many factors,including but not limited to,
usage volumes,service,outage,customer's equipment,terrain,proximity to buildings,foliage,and
weather that may impact service.
The proposed site is needed to offload capacity from existing sites.The maps also reflect the
predicted coverage area that will be offloaded from existing sites and transferred to the proposed
site.
Sincerely,
Brian Robbins
RF Engineer, Verizon Wireless
GN 131St And Sheffield–123’
Each color
represents area
served
by a specific site
GN 131St And Sheffield–148’
Each color
represents area
served
by a specific site
From:Rick Helmbright
To:"kyle.miller1@charter.com"; "steve.creech@charter.com"
Subject:FW: TAC Project # PZ-2022-00047 Crown Castle Cell Tower replacement
Date:Sunday, March 27, 2022 10:57:13 AM
Attachments:City of Carmel-TAC Application - Crown Castle_3-21-22.PDF
image001.png
A010.0=Architectural Elevation_ 1531 W Main St Carmel IN.pdf
C010.0= Civil Engineering - Geotech report.pdf
S=Structural_Crown Tower swap - Pole & Foundation Designs.pdf
SPP010.0=Survey-Plot Plan_ Floodway Location Map.pdf
Mr. Creech, Mr. Miller
Attached please find the documents for the subject Crown Castle Cell Tower replacement project.
Regards,
Richard Helmbright
Kendall Communications LLC
Business Manager
2005 Sutter parkway
Dublin, OH 43016
Mobile; 614-928-1108
Rick@Kendallcommunications.net
CONFIDENTIALITY NOTICE: If you have received this email in error, please immediately notify the sender by e-
mail at the address shown. This email transmission may contain confidential information. This information is
intended only for the use of the individual(s) or entity to whom it is intended even if addressed incorrectly. Please
delete it from your files if you are not the intended recipient. Thank you for your compliance.
From:Rick Helmbright
To:Ryan.Daugherty@duke-energy.com
Subject:FW: TAC Project # PZ-2022-00047 Crown Castle Cell Tower replacement
Date:Sunday, March 27, 2022 11:01:38 AM
Attachments:City of Carmel-TAC Application - Crown Castle_3-21-22.PDF
image001.png
A010.0=Architectural Elevation_ 1531 W Main St Carmel IN.pdf
C010.0= Civil Engineering - Geotech report.pdf
S=Structural_Crown Tower swap - Pole & Foundation Designs.pdf
SPP010.0=Survey-Plot Plan_ Floodway Location Map.pdf
Mr. Daugherty,
Attached please find the documents for the subject Crown Castle Cell Tower replacement project.
Project address 1531 West Main St, Carmel, IN 46032
Regards,
Richard Helmbright
Kendall Communications LLC
Business Manager
2005 Sutter parkway
Dublin, OH 43016
Mobile; 614-928-1108
Rick@Kendallcommunications.net
CONFIDENTIALITY NOTICE: If you have received this email in error, please immediately notify the sender by e-
mail at the address shown. This email transmission may contain confidential information. This information is
intended only for the use of the individual(s) or entity to whom it is intended even if addressed incorrectly. Please
delete it from your files if you are not the intended recipient. Thank you for your compliance.
From:Rick Helmbright
To:"travis.krick@duke-energy.com"; "reece.heilers@duke-energy.com"; "jessi.herrington@duke-energy.com"
Subject:FW: TAC Project # PZ-2022-00047 Crown Castle Cell Tower replacement
Date:Sunday, March 27, 2022 10:58:55 AM
Attachments:City of Carmel-TAC Application - Crown Castle_3-21-22.PDF
image001.png
A010.0=Architectural Elevation_ 1531 W Main St Carmel IN.pdf
C010.0= Civil Engineering - Geotech report.pdf
S=Structural_Crown Tower swap - Pole & Foundation Designs.pdf
SPP010.0=Survey-Plot Plan_ Floodway Location Map.pdf
To TAC Members,
Attached please find the documents for the subject Crown Castle Cell Tower replacement project.
Regards,
Richard Helmbright
Kendall Communications LLC
Business Manager
2005 Sutter parkway
Dublin, OH 43016
Mobile; 614-928-1108
Rick@Kendallcommunications.net
CONFIDENTIALITY NOTICE: If you have received this email in error, please immediately notify the sender by e-
mail at the address shown. This email transmission may contain confidential information. This information is
intended only for the use of the individual(s) or entity to whom it is intended even if addressed incorrectly. Please
delete it from your files if you are not the intended recipient. Thank you for your compliance.
From:Rick Helmbright
To:dan.davenport@aes.com; rodney.johnson@aes.com; tom.wroblewski@aes.com
Subject:FW: TAC Project # PZ-2022-00047 Crown Castle Cell Tower replacement
Date:Sunday, March 27, 2022 11:03:32 AM
Attachments:City of Carmel-TAC Application - Crown Castle_3-21-22.PDF
image001.png
A010.0=Architectural Elevation_ 1531 W Main St Carmel IN.pdf
C010.0= Civil Engineering - Geotech report.pdf
S=Structural_Crown Tower swap - Pole & Foundation Designs.pdf
SPP010.0=Survey-Plot Plan_ Floodway Location Map.pdf
TAC Members,
Attached please find the documents for the subject Crown Castle Cell Tower replacement project.
Regards,
Richard Helmbright
Kendall Communications LLC
Business Manager
2005 Sutter parkway
Dublin, OH 43016
Mobile; 614-928-1108
Rick@Kendallcommunications.net
CONFIDENTIALITY NOTICE: If you have received this email in error, please immediately notify the sender by e-
mail at the address shown. This email transmission may contain confidential information. This information is
intended only for the use of the individual(s) or entity to whom it is intended even if addressed incorrectly. Please
delete it from your files if you are not the intended recipient. Thank you for your compliance.
From:Rick Helmbright
To:ckehl@citizensenergygroup.com
Subject:FW: TAC Project # PZ-2022-00047 Crown Castle Cell Tower replacement
Date:Sunday, March 27, 2022 11:04:12 AM
Attachments:City of Carmel-TAC Application - Crown Castle_3-21-22.PDF
image001.png
A010.0=Architectural Elevation_ 1531 W Main St Carmel IN.pdf
C010.0= Civil Engineering - Geotech report.pdf
S=Structural_Crown Tower swap - Pole & Foundation Designs.pdf
SPP010.0=Survey-Plot Plan_ Floodway Location Map.pdf
TAC Member,
Attached please find the documents for the subject Crown Castle Cell Tower replacement project.
Regards,
Richard Helmbright
Kendall Communications LLC
Business Manager
2005 Sutter parkway
Dublin, OH 43016
Mobile; 614-928-1108
Rick@Kendallcommunications.net
CONFIDENTIALITY NOTICE: If you have received this email in error, please immediately notify the sender by e-
mail at the address shown. This email transmission may contain confidential information. This information is
intended only for the use of the individual(s) or entity to whom it is intended even if addressed incorrectly. Please
delete it from your files if you are not the intended recipient. Thank you for your compliance.
For the best experience, open this PDF portfolio in
Acrobat X or Adobe Reader X, or later.
Get Adobe Reader Now!
March 27,2022
Mr. Chris Ellison– TAC Member
Office of Fire Chief, Fire Station #1
10701 N College Ave
Indianapolis, IN 46280
Re; TAC – Project # PZ-2022-00047
Crown Castle Cell Tower replacement
Mr. Ellison,
Attached for your review, please find copies of the proposed Crown Castle Cell tower replacement project.
All copies of the documents have been uploaded in City of Carmel -ProjectDox.
Regards,
Richard Helmbright
Business Manager
Kendall Communications
On behalf of Crown Castle
614-928-1108
Rick@Kendallcommunications.net
From:Rick Helmbright
To:david.lucas@hamiltoncounty.in.gov
Subject:Project # PZ-2022-00047- Crown Castle Cell Tower replacement
Date:Sunday, March 27, 2022 10:24:52 AM
Attachments:A010.0=Architectural Elevation_ 1531 W Main St Carmel IN.pdf
image001.png
C010.0= Civil Engineering - Geotech report.pdf
S=Structural_Crown Tower swap - Pole & Foundation Designs.pdf
SPP010.0=Survey-Plot Plan_ Floodway Location Map.pdf
City of Carmel-TAC Application - Crown Castle_3-21-22.PDF
Mr. Lucas,
Attached please find the documents for the subject Crown Castle Cell Tower replacement.
Regards,
Richard Helmbright
Kendall Communications LLC
Business Manager
2005 sutter Parkway
Dublin, OH 43016
Mobile; 614-928-1108
Rick@Kendallcommunications.net
CONFIDENTIALITY NOTICE: If you have received this email in error, please immediately notify the sender by e-
mail at the address shown. This email transmission may contain confidential information. This information is
intended only for the use of the individual(s) or entity to whom it is intended even if addressed incorrectly. Please
delete it from your files if you are not the intended recipient. Thank you for your compliance.
From:Rick Helmbright
To:"erussell@carmel.in.gov"
Subject:Project# PZ-2022-00047 - TAC Crown Castle Cell Tower Replacement
Date:Sunday, March 27, 2022 10:20:02 AM
Attachments:A010.0=Architectural Elevation_ 1531 W Main St Carmel IN.pdf
image001.png
C010.0= Civil Engineering - Geotech report.pdf
SPP010.0=Survey-Plot Plan_ Floodway Location Map.pdf
S=Structural_Crown Tower swap - Pole & Foundation Designs.pdf
Mr. Russell,
Attached Pleas find the PDF copy of the documents for the Crown Castle Cell Tower replacement.
A paper copy is mailed to your attention.
Regards,
Richard Helmbright
Kendall Communications LLC
Business Manager
2005 Sutter Parkway
Dublin, OH 43016
Mobile; 614-928-1108
Rick@Kendallcommunications.net
CONFIDENTIALITY NOTICE: If you have received this email in error, please immediately notify the sender by e-
mail at the address shown. This email transmission may contain confidential information. This information is
intended only for the use of the individual(s) or entity to whom it is intended even if addressed incorrectly. Please
delete it from your files if you are not the intended recipient. Thank you for your compliance.
From:Rick Helmbright
To:Keesling, Rachel M; Conn, Angelina V; Lopez, Alexia K; dmindham@carmel.in.gov; dlittlejohn@carmel.in.gov;
dmccoy@carmel.in.gov; Samuel.Clark@hamiltoncounty.in.gov; whall@crossroadengineers.com;
ajordan@carmel.in.gov; jthomas@carmel.in.gov; msheeks@carmel.in.gov; whohlt@carmel.in.gov;
drutti@carmel.in.gov; jduffy@carmel.in.gov; jjstewart@carmel.in.gov; mhendricks@carmel.in.gov;
jbarlow@carmel.in.gov; dstrong@carmel.in.gov; cellison@carmel.in.gov; tkrueskamp@carmel.in.gov;
mklitzing@carmelclayparks.com; Chad.R.Miller@centerpointenergy.com; ryan.hartman@trico.eco
Subject:Project# PZ-2022-00047 Crown Castle Cell Tower replacement
Date:Sunday, March 27, 2022 10:38:56 AM
Attachments:image001.png
To TAC Members,
Regarding the subject Project, PZ-2022-00047 Crown Castle Cell Tower Replacement, the plans and documents
are uploaded in Project DOX
Regards,
Richard Helmbright
Kendall Communications LLC
Business Manager
2005 Sutter Parkway
Dublin, OH 43016
Mobile; 614-928-1108
Rick@Kendallcommunications.net
CONFIDENTIALITY NOTICE: If you have received this email in error, please immediately notify the sender by e-
mail at the address shown. This email transmission may contain confidential information. This information is
intended only for the use of the individual(s) or entity to whom it is intended even if addressed incorrectly. Please
delete it from your files if you are not the intended recipient. Thank you for your compliance.
CAUTION: This email originated from outside of the organization. Do not click links or open
attachments unless you recognize the sender and know the content is safe.
From:David E. Lucas
To:Rick Helmbright
Subject:RE: Project # PZ-2022-00047- Crown Castle Cell Tower replacement
Date:Monday, March 28, 2022 7:51:29 AM
Attachments:image002.png
image003.png
image004.png
image005.png
image006.png
image007.png
image008.png
image009.png
This project is outside of County jurisdiction. Highway has no comments or concerns.
David Lucas | Project Coordinator
Hamilton County Highway Department
1700 S. 10th St. | Noblesville, IN 46060
david.lucas@hamiltoncounty.in.gov
317.773.7770 - office
From: Rick Helmbright <rick@kendallcommunications.net>
Sent: Sunday, March 27, 2022 10:25 AM
To: David E. Lucas <David.Lucas@hamiltoncounty.in.gov>
Subject: Project # PZ-2022-00047- Crown Castle Cell Tower replacement
Mr. Lucas,
Attached please find the documents for the subject Crown Castle Cell Tower replacement.
Regards,
Richard Helmbright
Kendall Communications LLC
Business Manager
2005 sutter Parkway
Dublin, OH 43016
Mobile; 614-928-1108
Rick@Kendallcommunications.net
CONFIDENTIALITY NOTICE: If you have received this email in error, please immediately notify the sender by e-
mail at the address shown. This email transmission may contain confidential information. This information is
intended only for the use of the individual(s) or entity to whom it is intended even if addressed incorrectly. Please
delete it from your files if you are not the intended recipient. Thank you for your compliance.
The information in this email may contain confidential information and is intended solely for the attention
and use of the named addressee(s). It must not be disclosed to any person(s) without authorization. If you are
not the intended recipient, or a person responsible for delivering it to the intended recipient, you are not
authorized to, and must not disclose, copy, distribute, or retain this message or any part of it. If you have
received this communication in error, please notify the sender immediately.
From:Dan Davenport
To:Rick Helmbright; Rodney E. Johnson (MS)
Subject:RE: TAC Project # PZ-2022-00047 Crown Castle Cell Tower replacement
Date:Sunday, March 27, 2022 1:35:33 PM
Attachments:image002.png
image003.png
image004.png
Project is located outside of AES Indiana’s service area. No comments.
Dan Davenport
Team Leader
Customer Projects Engineering
Office: 317-261-5497
From: Rick Helmbright <rick@kendallcommunications.net>
Sent: Sunday, March 27, 2022 11:04 AM
To: Dan Davenport <dan.davenport@aes.com>; Rodney E. Johnson (MS)
<rodney.johnson@aes.com>; tom.wroblewski@aes.com
Subject: FW: TAC Project # PZ-2022-00047 Crown Castle Cell Tower replacement
USE CAUTION: External Sender
TAC Members,
Attached please find the documents for the subject Crown Castle Cell Tower replacement project.
Regards,
Richard Helmbright
Kendall Communications LLC
Business Manager
2005 Sutter parkway
Dublin, OH 43016
Mobile; 614-928-1108
Rick@Kendallcommunications.net
CONFIDENTIALITY NOTICE: If you have received this email in error, please immediately notify the sender by e-
mail at the address shown. This email transmission may contain confidential information. This information is
intended only for the use of the individual(s) or entity to whom it is intended even if addressed incorrectly. Please
delete it from your files if you are not the intended recipient. Thank you for your compliance.
From:Carlson, Nathaniel
To:Rick Helmbright
Cc:Wood, Mark A.; Yackle, Troy
Subject:RE: TAC Project # PZ-2022-00047 Crown Castle Cell Tower replacement
Date:Monday, March 28, 2022 8:05:31 AM
Attachments:image011.png
image001.png
image002.png
image003.png
image012.png
image013.png
image014.png
image015.png
City of Carmel-TAC Application - Crown Castle_3-21-22.PDF
A010.0=Architectural Elevation_ 1531 W Main St Carmel IN.pdf
C010.0= Civil Engineering - Geotech report.pdf
S=Structural_Crown Tower swap - Pole & Foundation Designs.pdf
SPP010.0=Survey-Plot Plan_ Floodway Location Map.pdf
Rick,
Panhandle Eastern does not have facilities within the proposed project area.
Thank you,
Nate CarlsonAssociate ROW RepresentativeEastern Division–Zionsville, INPanhandle Eastern Pipe LineCompany, LPTrunkline Gas Company, LLC O: 317.733.3266C: 585.943.0459
From: Rick Helmbright <rick@kendallcommunications.net>
Sent: Sunday, March 27, 2022 11:07 AM
To: tfenogli@ccs.k12.in.us; Yackle, Troy <Troy.Yackle@energytransfer.com>;
Lisa.V.Dalton@usps.gov; wl807s@att.com; Marc.Hill@metronetinc.com
Subject: FW: TAC Project # PZ-2022-00047 Crown Castle Cell Tower replacement
TAC Members,
Attached please find the documents for the subject Crown Castle Cell Tower replacement project.
Regards,
Richard Helmbright
Kendall Communications LLC
Business Manager
2005 Sutter parkway
Dublin, OH 43016
Mobile; 614-928-1108
Rick@Kendallcommunications.net
CONFIDENTIALITY NOTICE: If you have received this email in error, please immediately notify the sender by e-
mail at the address shown. This email transmission may contain confidential information. This information is
intended only for the use of the individual(s) or entity to whom it is intended even if addressed incorrectly. Please
delete it from your files if you are not the intended recipient. Thank you for your compliance.
Private and confidential as detailed here. If you cannot access hyperlink, please e-mail sender.
From:Daugherty, Ryan
To:Rick Helmbright
Subject:RE: [EXTERNAL] FW: TAC Project # PZ-2022-00047 Crown Castle Cell Tower replacement
Date:Monday, March 28, 2022 8:24:27 AM
Attachments:image001.png
Rick- does this project require coordination with Duke Energy Telecom or Substation?
From: Rick Helmbright <rick@kendallcommunications.net>
Sent: Sunday, March 27, 2022 11:02 AM
To: Daugherty, Ryan <Ryan.Daugherty@duke-energy.com>
Subject: [EXTERNAL] FW: TAC Project # PZ-2022-00047 Crown Castle Cell Tower replacement
*** CAUTION! EXTERNAL SENDER *** STOP. ASSESS. VERIFY!! Were you expecting this
email? Are grammar and spelling correct? Does the content make sense? Can you verify the
sender? If suspicious report it, then do not click links, open attachments or enter your ID or
password.
Mr. Daugherty,
Attached please find the documents for the subject Crown Castle Cell Tower replacement project.
Project address 1531 West Main St, Carmel, IN 46032
Regards,
Richard Helmbright
Kendall Communications LLC
Business Manager
2005 Sutter parkway
Dublin, OH 43016
Mobile; 614-928-1108
Rick@Kendallcommunications.net
CONFIDENTIALITY NOTICE: If you have received this email in error, please immediately notify the sender by e-
mail at the address shown. This email transmission may contain confidential information. This information is
intended only for the use of the individual(s) or entity to whom it is intended even if addressed incorrectly. Please
delete it from your files if you are not the intended recipient. Thank you for your compliance.
From:Rick Helmbright
To:"jason.lemaster@hamiltoncounty.in.gov"; "health@hamiltoncounty.in.gov"
Subject:TAC Project # PZ-2022-00047 Crown Castle Cell Tower replacement
Date:Sunday, March 27, 2022 10:53:45 AM
Attachments:City of Carmel-TAC Application - Crown Castle_3-21-22.PDF
image001.png
A010.0=Architectural Elevation_ 1531 W Main St Carmel IN.pdf
C010.0= Civil Engineering - Geotech report.pdf
S=Structural_Crown Tower swap - Pole & Foundation Designs.pdf
SPP010.0=Survey-Plot Plan_ Floodway Location Map.pdf
Mr. Lemaster,
Attached please find the documents for the subject Crown Castle Cell Tower replacement project.
Regards,
Richard Helmbright
Kendall Communications LLC
Business Manager
2005 Sutter parkway
Dublin, OH 43016
Mobile; 614-928-1108
Rick@Kendallcommunications.net
CONFIDENTIALITY NOTICE: If you have received this email in error, please immediately notify the sender by e-
mail at the address shown. This email transmission may contain confidential information. This information is
intended only for the use of the individual(s) or entity to whom it is intended even if addressed incorrectly. Please
delete it from your files if you are not the intended recipient. Thank you for your compliance.