Loading...
HomeMy WebLinkAboutA041-FAIR HOUSING BLOCKING DETAILSMINIMUM REINFORCING BEHIND TOILETS LOCATED BESIDE A WALL MINIMUM REINFORCED AREA- AN ADDITIONAL 2" MIN EACH SIDE AND BOTTOM IS RECOMMENDED TO MOUNT 24" STANDARD GRAB BAR12" MIN. 12" MIN. 18"32" MAX30" MAX PREFERRED38" MIN.28"-32" REINFORCING AREA SHOULD BE PROVIDED TO ACCOMMODATE A 24" GRAB BAR12" MIN.24" MIN.42" PREFERREDWHEREVER POSSIBLE, SIDE REINFORCING SHOULD ACCOMMODATE A 42" GRAB BAR MINIMUM REINFORCING BEHIND TOILETS LOCATED BESIDE A PARTIAL WALL 18" 12" MIN. 12" MIN. 18" 18"32" MAX30" MAX PREFERRED38" MIN.32" MAX30" MAX PREFERRED3'-2" MIN. 6"MAX. MINIMUM REINFORCING @ BATHTUBS WITHOUT PERMANENT SEATS MINIMUM REINFORCING IN SHOWERS 32" MAX30" MAX PREFERRED38" MIN.ELONGATED REINFORCING FOR POSSIBLE ADDITION OF FOLDING GRAB BAR WHERE TOILETS DO NOT HAVE FULL SIDE BAR REINFORCING, REINFORCEMENT BEHIND THE TOILET MUST BE ENLARGED TO SUPPORT A FOLD-DOWN GRAB BAR ASSEMBLY 18" 2'-2" MIN. 2'-2" MIN.6" MIN.WALL TO WALL REINFORCING WALL TO WALL REINFORCING 6"MAX. 6"MAX. PROVIDE BLOCKING FOR FUTURE INSTALLATION OF GRAB BARS AND SEATING PER SEC. 607.4 ANSI 117.1-2009 6"MAX.6" MAX.2'-4" MIN.2'-2" MIN.PROVIDE BLOCKING FOR FUTURE INSTALLATION OF GRAB BARS AND SEATING PER SEC. 604.5 ANSI 117.1-2009 PROVIDE BLOCKING FOR FUTURE INSTALLATION OF GRAB BARS AND SEATING PER SEC(S). 608.3, 608.2.1.3, 608.2.2.3, & 608.2.3.2 ANSI 117.1-20096" MIN.2'-4" MIN.4'-0"MIN. A041FAIR HOUSINGBLOCKING DETAILSSCALE: 01 TYPICAL BLOCKING DIAGRAMS 1/2" = 1'-0"ARCHITECTCLIENT CONSTRUCTION MANAGER PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20011 APRIL 28, 2021AVANT PHASE IICARMEL, INEDWARD ROSEDEVELOPMENTCARMEL LLC.PERMIT SET No. AR12000062 STATE OF MDXELA ARS H T E C TCHI AR STGI R E E DER IANDI N A 10/11/21