Loading...
HomeMy WebLinkAboutA152_SECOND THROUGH FOURTH FLOOR OVERALL REFLECTED CEILING PLANDNUPDNUPLF12LF12LF12 LF12 LF12 LF12LF12LF12LF12LF11LF11LF11 LF11 LF11LF11LF11 LF11 LF13LF13LF13LF13LF13LF13LF13LF13 LF13LF13LF13LF13LF13LF11LF11LF11LF11LF11LF11LF11 LF11 LF11LF11 LF11LF13LF11LF11LF11LF11LF11LF11LF11LF11LF11LF11LF11 LF11 LF11 LF11LF11 LF11LF11LF11LF11LF11LF11LF11LF11LF11LF11LF11LF11LF11 LF11 LF11LF11 LF11 LF12 LF13LF13ARCHITECTCLIENT CONSTRUCTION MANAGER PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20011 APRIL 28, 2021AVANT PHASE IICARMEL, INEDWARD ROSEDEVELOPMENTCARMEL LLC.PERMIT SET No. AR12000062 STATE OF MDXELA ARS H T E C TCHI AR STGI R E E DER IANDI N A A152SECOND THROUGHFOURTH FLOOROVERALL REFLECTEDCEILING PLANGENERAL NOTES 1. THE GENERAL CONTRACTOR SHALL VERIFY ALL CONDITIONS AT THE JOBSITE. NOTIFY ARCHITECT OF ANY DEVIATIONS FROM THOSE CONDITIONS AS THEY ARE NOTED ON THE DRAWINGS. 2. 0'-0" CORRELATES TO 862.35' ON CIVIL DRAWINGS. 3. THE GENERAL CONTRACTOR SHALL COORDINATE AND SCHEDULE ALL WORK WITH THE OWNER. 4. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL STATE AND LOCAL BUILDING CODES AND GOVERNMENT REGULATORY AGENCIES. 5. THE GENERAL CONTRACTOR IS TO SUBMIT SHOP DRAWINGS, PROJECT DATA, AND SAMPLES TO OWNER/ARCHITECT FOR APPROVAL PRIOR TO FABRICATION OF ALL MILLWORK AND WALL FINISHES. 6. DO NOT SCALE ANY DRAWING. ANY DIMENSIONS ARE TO BE OBTAINED FROM THE ARCHITECT IF NOT NOTED ON THE DRAWINGS. REFER ALL QUESTIONS TO THE ARCHITECT OR E.O.R. 7. ALL DIMENSIONS ARE TO C.L. OF DEMISING WALL OF UNITS AND FACE OF FRAMING. 8. THE GENERAL CONTRACTOR SHALL KEEP ONE SET OF PLANS AT THE JOBSITE FOR THE SPECIFIC PURPOSE OF RECORDING ACTUAL CONSTRUCTION CONDITIONS. SUCH PROJECT RECORD-DOCUMENTS SHALL BE PROVIDED TO THE OWNER UPON COMPLETION OF THE PROJECT. 9. THE GENERAL CONTRACTOR SHALL VERIFY SIZE, LOCATION, AND CHARACTERISTICS OF ALL WORKS AND EQUIPMENT SUPPLIED BY THE OWNER OR OTHERS WITH THE MANUFACTURER OR SUPPLIER PRIOR TO THE START OF THE WORK. 10. THE GENERAL CONTRACTOR SHALL SEE THAT ALL SUBCONTRACTORS RECEIVE COMPLETE WORKING DRAWINGS AND ASSUME FULL RESPONSIBILITY FOR COORDINATION OF WORK. 11. PRIMARY ENTRANCE DOOR NUMBERS CORRESPOND TO ROOM NUMBERS OR UNIT NUMBERS. SCALE: 01 SECOND THROUGH FOURTH FLOOR OVERALL REFLECTED CEILING PLAN 3/32" = 1'-0" DATA D201 MECH M2O1 MECH M202 N. COORNC101 E. COOR EC101 S. COORSC101W. COOR WC101 8'-0" 10'-0" TYP.EQ. EQ.10'-0" 10'-0"10'-0" TYP. EQ.EQ. 10'-0" 10'-0"EQ. EQ. NOTE: SEE A400 SERIES FOR UNIT REFLECTED CEILING PLANS. NOTE: ALL CEILING MATERIAL SHOULD BE GYPSUM BOARD UNLESS NOTED OTHERWISE. REFER TO A031 FOR ADDITIONAL INFORMATION LIGHT SCHEDULE LF11 - SURFACE MOUNT DOWNLIGHT LF12 - SURFACE MOUNT UTILITY LIGHT LF13 - WALL MOUNTED SCONCE & UNIT I.D. SIGNAGE CEILING PLAN NOTES PROVIDE WOOD TRIM STAINED (S1). DRYWALL CEILING BETWEEN TRIM TO BE PAINTED (P10). 1 E.J.E.J.7'-91516" 17'-218"E.J. E.J.E.J. E.J. E.J. 10/11/21