Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A382_SECTION DETAILS
ARCHITECTCLIENT CONSTRUCTION MANAGER PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20011 APRIL 28, 2021AVANT PHASE IICARMEL, INEDWARD ROSEDEVELOPMENTCARMEL LLC.PERMIT SET No. AR12000062 STATE OF MDXELA ARS H T E C TCHI AR STGI R E E DER IANDI N A A382SECTION DETAILSB1SCALE: 01 DETAILS SECTION 3" = 1'-0" SCALE: 02 DETAILS SECTION 3" = 1'-0" SCALE: 03 DETAILS SECTION 3" = 1'-0" SCALE: 04 DETAILS SECTION 3" = 1'-0"F2F2F2 SCALE: 05 DETAILS SECTION 3" = 1'-0" SCALE: 06 DETAILS SECTION 3" = 1'-0" SCALE: 07 DETAILS SECTION 3" = 1'-0" SCALE: 08 DETAILS SECTION 3" = 1'-0" SCALE: 09 DETAILS SECTION 3" = 1'-0" SCALE: 10 DETAILS SECTION 3" = 1'-0"F1SCALE: 11 DETAILS SECTION 3" = 1'-0" SCALE: 12 DETAILS SECTION 3" = 1'-0" FASCIA BOARD, FINISH TO MATCH EW2b 2x10 BALCONY FRAMING, REFER TO STRUCTURAL DRAWINGS 12" DROP BEAM- REFER TO STRUCTURAL DRAWING. PAINTED TO MATCH FASCIA KICK-OUT FLASHING- EXTEND MEMBRANE UP AND OVER TOP OF FRAMING914"ALUMINUM BALCONY RAILINGS W/ MESH INSERT, TYP. 2x10 LEDGER BOARDS & HANGER- REFER TO STRUCTURAL DRAWINGS EW4a612"BASE REVEAL TRIM, FRY REGLET OR EQUAL. INCLUDE KICK-OUT FLASHING 34" BASE TRIM, PER SCHEDULE BASE TRIM, PER SCHEDULE 2x10 LEDGER BOARDS & HANGER- REFER TO STRUCTURAL DRAWINGS BASE REVEAL TRIM, FRY REGLET OR EQUAL. INCLUDE KICK-OUT FLASHING 34"METAL FLASHING W/ DRIP EDGE- SET ON MORTAR BED TO ENSURE POSITIVE DRAINAGE CELL VENT & WEEP INSTALLED @ 24" O.C. HORIZONTALLY 14" SOLDIER COURSE FIBER CEMENT SOFFIT PANEL INTERIOR CORNER TRIM REVEAL, FRY REGLET OR EQUAL CELL VENT & WEEP INSTALLED @ 24" O.C. HORIZONTALLY MORTAR NET THRU-WALL FLASHING ACM PANEL 7/16" SHEATHING & BUILDING WRAP LOW ROOF FRAMING -REFER TO STRUCTURAL BASE TRIM, PER SCHEDULE LAYER TPO ROOFING FOR REINFORCEMENT @ CORNERS 2x_ TREATED BLOCKING FOR SLOPE BASE FLASHING PRE-FINISHED COPING GRAVEL STOP W/ DRIP & CONTINUOUS CLEAT714"2x_ TREATED NAILERS CANT STRIP BASE FLASHING PRE-FINISHED COPING GRAVEL STOP W/ DRIP & CONTINUOUS CLEAT714"CANT STRIP 2x_ TREATED NAILER LAYER TPO ROOFING FOR REINFORCEMENT @ CORNERS 12" CONTROL JOINT & SEALANT 2" RIGID INSULATION W/ VAPOR BARRIER BELOW GRADE- EXTEND TO BOTTOM OF FOOTING 1'-534"2x_ TREATED NAILERS ROOF PARAPET FRAMING- REFER TO STRUCTURAL DRAWINGS PRE-FINISHED COPING FASCIA W/ CONTINUOUS FULL-LENGTH WIND CLEAT 3/4" EXTERIOR DECKING TPO ROOFING CELL VENT & WEEP INSTALLED @ 24" O.C. HORIZONTALLY DOUBLE SOLDIER COURSING CAST STONE STRING COURSING W/ DRIP 1'-2" 158"1"THRU-WALL FLASHING CELL VENT & WEEP INSTALLED @ 24" O.C. HORIZONTALLY MORTAR NET 138"14" EW4a EW4a EW1 EW1 EW1 EW1 CELL VENT & WEEP INSTALLED @ 24" O.C. HORIZONTALLY DOUBLE SOLDIER COURSING CAST STONE STRING COURSING W/ DRIP 1'-2" 158"1"THRU-WALL FLASHING138"14"38"EW4 BASE REVEAL TRIM, FRY REGLET OR EQUAL SOLDIER COURSE OVER OPENING MORTAR NET CELL VENT & WEEP INSTALLED @ 24" O.C. HORIZONTALLY THRU-WALL FLASHING TROWEL MORTAR TO CREATE POSITIVE DRAINAGE 14" FIBER CEMENT SOFFIT PANEL @ OPENING HEADER BEAM @ OPENING- REFER TO STRUCTURAL DRAWINGS 4"14" PER 12" 14" PER 12" MIN. 14" PER 12" MIN. 10/11/21