HomeMy WebLinkAboutE402 - ENLARGED ELECTRICAL PLANS63 1154
SS S
S
S
S
S
S
S
S
S
S
SS FCU-2
17,19
WH-2
14,16
CU-2
13,15
A5
4
A1
4
A1
3
A1
5
A1
3
A5
4
8
8
8
23
23
23
21
21
21
3
3
5
6
11
11 24
PNL-B111
13
8
9
9
10
10
5
1512
73
4
21
16
14 14
6
8
14
14
8
22
18,20
9
C
C
H
A
A
B
B
21
21
11
11
11 11
2
11
11
23
8
8
5
A1
3
A4
3
A1
5
A4
5
A4
5
A3
4
A5
4
A1
4
A1
4
A1
4
A1
4
A1
4 A1
4
7
7
K
I
17
F
A6WP
23 4
10,12
11
A1
5
FCU-2
13,15
WH-2
10,12
CU-2
9,11
A5
1
A1
3
A1
1
A1
1 A1
1
A1
1
A1
3
A5
1
19
19
19
33 20
17
2
2
7
7
7
5 5
5
33
2
14,16
6,8
4PNL-B21 2
37
4
9
11
16
9
10
8
8
5
13
15
8
10
14
14
14
14
4
19
A
A
B
C
11
19
12
7
7
2
2
2
5 5
A4
3
A1
1
A1
1A1
1
A1
1
A3
1
A4
3
B
A1
1
K
L
I
H
C
A5
1
6
WP
7
A6
1 J
A1
3
11
18
21
2
FCU-2
14,16WH-2
13,15
CU-2
10,12
A5
3
9
9
14
14 14PNL-B33
17,19
1
6
7
21
4
4
5
20
3
18
18
8
3
7
6
A1
A5
A1
A1
3
A1
9,11
20
7
3
10
11
1
2
5
8
8
13
12 15
A
A
B
B
C
C
20
20
20
20
18
18
18
6
18
7
7
7
16 A1
3
A1
3
A1
3
A1
4
A1
4
A4
4
4
A4
4
A1
23
A1
23
23
A4
2310
A3
3
2
G
E
I
Q
M
8
A1
3
A1
3
666
A5
3
WP
3A6
3
F
11
11
236
9
4
A1
3
O ARCHITECTCLIENT CONSULTANT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONSKBSO Consulting1344 S Rangeline Rd. Suite 202CARMEL, INDIANA 46032P: 317-344-8044PERMIT SET
APRIL 28TH, 2021
20005THE AVANTPHASE IIE402ENLARGEDELECTRICAL PLANSCARMEL,IN1/4" = 1'-0"
ENLARGED UNIT B1 ELECTRICAL PLAN 1
1/4" = 1'-0"
ENLARGED UNIT B2 ELECTRICAL PLAN2
1/4" = 1'-0"
ENLARGED UNIT B3 ELECTRICAL PLAN3
GENERAL NOTES
A REFER TO SHEET E-000 FOR GENERAL ELECTRICAL NOTES, SYMBOLS AND
ABBREVIATIONS.
B REFER TO SHEET E601 FOR LIGHT FIXTURE SCHEDULE.
C REFER TO E600 SERIES SHEETS FOR LOAD CENTER CIRCUIT SCHEDULES FOR
EACH DWELLING UNIT TYPE.
D ELECTRICAL LAYOUTS SHOWN SHALL BE TYPICAL FOR EACH RESIDENTIAL
UNIT TYPE IDENTIFIED UNLESS NOTED OTHERWISE.
E LIGHT FIXTURE LOCATIONS SHOWN SHALL BE SUPERCEDED BY THE
ARCHITECTURAL REFLECTED CEILING PLANS.
F INSTALL MULTIPLE SWITCHES SHOWN IN SINGLE LOCATION BEHINE A SINGLE
MULTI-GANG SWITCH FACEPLATE. INSTALL A MAXIMUM OF FOUR (4)
SWITCHES BEHIND A SINGLE SWITCH FACEPLATE.
G CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF MECHANICAL
EQUIPMENT WITH THE MECHANICAL CONTRACTOR. EXACT ELECTRICAL
REQUIREMENTS SHALL BE FIELD VERIFIED AGAINST THE EQUIPMENT NAME
PLATE DATA. THE CONTRACTOR SHALL MAKE APPROPRIATE ADJUSTMENTS
OF FEEDER CIRCUIT CONDUCTORS AND OVERCURRENT PROTECTION PER
MANUFACTURER.
H ALL RECEPTACLES LOCATED IN KITCHENS AND BATHROOMS SHALL BE GFCI
TYPE.
I LOAD CENTERS FOR EACH DWELLING UNIT SHALL BE RECESSED IN WALL AS
INDICATED. LOAD CENTER SHALL NOT BE INSTALLED IN DEMISING WALL.
J PROVIDE DUPLEX RECEPTACLE ON DEDICATED CIRCUIT IN
HOMENETWORKING CABINET.
K ALL SMOKE ALARM DEVICES WITHIN EACH DWELLING UNIT SHALL BE
INTERCONNECTED AND ONLY ALARM WITHIN THE DWELLING UNIT THEY
RESIDE.
L THE BUILDING FIRE ALARM CONTROL PANEL SHALL MONITOR THE STATUS OF
EACH SMOKE ALARM UNIT WITHIN EACH DWELLING UNIT.
M DWELLING UNIT SMOKE ALARM DEVICES SHALL BE POWERED BY THE
BUILDING FIRE ALARM SYSTEM.
N PROVIDE LOW FREQUENCY SOUNDER BASE WITHIN EACH SLEEPING AREA
AND LIVING AREA ON EACH DWELLING UNIT TYPE. AUDIBLE DEVICES SHALL
ALARM UPON ACTIVATION OF BUILDING FIRE ALARM SYSTEM AND DWELLING
UNIT SMOKE ALARM DEVICES.
O DWELLING UNITS NOTED AS ADA ACCESSIBLE SHALL BE EQUIPPED WITH FIRE
ALARM VISUAL DEVICES WITHIN BEDROOMS, BATHROOMS AND COMMON
LIVING AREA.
P DWELLING UNITS NOTED AS ADA ACCESSIBLE ELECTRICAL PANELS SHALL BE
MOUNTED SO AS THE HIGHEST BREAKER IS NO HIGHER THAN 48" ABOVE
FINISHED FLOOR.
SWITCHING SCHEDULE
TYPE 1ST SWITCH FUNCTION 1ST SWITCH TYPE 2ND SWITCH FUNCTION 2ND SWITCH TYPE 3RD SWITCH FUNCTION 3RD SWITCH TYPE 4TH SWITCH FUNCTION 4TH SWITCH TYPE
A BEDROOM "A5" FIXTURE DUAL SLIDE SWITCH FOR SEPERATE FAN
AND LIGHT CONTROL
BEDROOM SWITCHED RECEPTACLE SNAP
B BATHROOM FIXTURES SNAP BATHROOM EXHAUST SNAP
C CLOSET "A1" FIXTURE SNAP
D DINING ROOM "A3" FIXTURE SNAP HALLWAY "A1" FIXTURE SNAP
E KITCHEN "A1" FIXTURES SNAP KITCHEN ISLAND "A1" FIXTURES SNAP
F PORCH "A6" FIXTURE SNAP LIVING ROOM "A5" FIXTURE DUAL SLIDE SWITCH FOR SEPERATE FAN
AND LIGHT CONTROL
LIVING ROOM SWITCHED RECEPTACLE SNAP
G ENTRY "A1" FIXTURE(S) SNAP
H LAUNDRY/MECHANICAL ROOM "A1" FIXTURE SNAP
I DINING ROOM "A3" FIXTURE SNAP
J PORCH "A6" FIXTURE SNAP
K ENTRY "A1" FIXTURE(S) SNAP KITCHEN "A1" FIXTURES SNAP KITCHEN ISLAND "A1" FIXTURES SNAP
L LIVING ROOM "A5" FIXTURE DUAL SLIDE SWITCH FOR SEPERATE FAN
AND LIGHT CONTROL
LIVING ROOM SWITCHED RECEPTACLE SNAP
M HALLWAY "A1" FIXTURE(S) SNAP
N BATHROOM FIXTURES 3-WAY SNAP
O ENTRY "A1" FIXTURE(S) 3-WAY SNAP
P BEDROOM "A5" FIXTURE DUAL SLIDE SWITCH FOR SEPERATE FAN
AND LIGHT CONTROL
BEDROOM SWITCHED RECEPTACLE SNAP BEDROOM "A1" FIXTURE SNAP
Q HALLWAY "A1" FIXTURE(S) 3-WAY SNAP
SHEET KEYNOTES
1 WASHER CONNECTION.FURNISH AND INSTALL A NEMA 5-20R RECEPTACLE (2) #12
AND (1) #12GND. COORDINATE EXACT REQUIREMENTS WITH EQUIPMENT INSTALLED.
2 DRYER CONNECTION .FURNISH AND INSTALL RECEPTACLE.(3) #10 AND (1)
#10GND.VERIFY FINAL RECEPTACLE TYPE AND EXACT REQUIREMENTS WITH
EQUIPMENT INSTALLLER PRIOR TO INSTALLATION.
3 RANGE/OVEN CONNECTION.FURNISH AND INSTALL RECEPTACLE (3) #6 AND 1 #10
GND.VERIFY FINAL RECEPTACLE TYPE AND EXACT REQUIREMENTS WITH EQUIPMENT
INSTALLER PRIOR TO INSTALLATION.
4 MOUNT RECEPTACLE 48" AFF FOR REFRIGERATOR
5 PROVIDE DEDICATED GFI RECEPTACLE AND WALL SWITCH FOR DISPOSAL
6 PROVIDE DEDICATED DUPLEX GFI RECEPTACE FOR DISHWASHER
7 MICROWAVE/HOOD CONNECTION.FURNISH AND INSTALL A NEMA 5-20R RECEPTACLE
IN AND (2) #12 AND (1) #12 GND. COORDINATE EXACT REQUIREMENTS WITH
EQUIPMENT INSTALLER FOR ANSI UNITS,PROVIDE JUNCTION BOX FOR AND AN ABOVE
COUNTER RECEPTACLE FOR COUNTER TOP MICR
8 SPLIT WIRED RECEPTACLE .WIRE TOP OUTLET TO WALL SWITCH AT ROOM ENTRY.
9 PROVIDE FAN RATED JUNCTION BOX FLUSH MOUNTED IN THE CEILING FOR CEILING
FAN
10 PROVIDE 120V CONNECTION TO BATHROOM EXHAUST FAN .PROVIDE WALL SWITCH
FOR CONTROL AND CONNECT LIGHTING TO CIRCUIT.
11 MOUNT TV RECEPTACLE AND DATA OUTLET IN LINE WITH EACH OTHER. EACH DATA
OUTLET TO CONSIST OF (1) RJ45 DATA JACK AND (1) COAX JACK BEHIND COMMON
WALLPLATE .PROVIDE COAX HOMERUN TO DATA ROOM ON ASSOCIATED FLOOR.
PROVIDE CAT-6 FROM DATA JACK TO 5 -PORT SWITCH IN UNIT LAUNDRY ROOM.
12 PROVIDE NON FUSED DISCONNECT AND 208 V .1-PH.30 a CIRCJIT FOR ELECTRICAL
WATER HEATER,USE (2) AND (1) #GND.
13 PROVIDE NON FUSED DISCONNECT AND 208 V,1 PH POWER CIRCUIT FOR CU UNIT
LOCATED ON ROOF.USE (2) #10 AND (1) #10 GND.
14 FURNISH AND INSTALL SMOKE DETECTIONB DEVICES AS SHOWN ON PLAN .SMOKE
DETECTOR WITH SOUNDER BASE CONNECTED TO UNSWITCHED HOT CONDUCTOR IN
CIRCUIT. BUILT IN STROBES IN HANDI-CAP UNITS THAT ARE FOR VISUALLY/hEARING
IMPAIRED . TYPICAL
15 PROVIDE NON FUSED DISCONNECT AND 208 V,1 PH ,35 A CIRCUIT FOR FCU-1. USE (2)
#10 AND (1) #10 GND.
16 PROVIDE DUPLEX RECEPTACLE AND DATA OUTLET MOUNTED AT +90". PROVIDE (5)
PORT DATA SWITCH MOUNTED ABOVE RECEPTACLE AND DATA OUTLET.USE MIKROTIK
RB260GS SWITCH OR OWNER APPROVED EQUAL.DATA OUTLET TO HAVE (6) RJ45
PORTS BEHIND SINGLE WALL PLATE.PROVIDE CAT-6 HOME RUN TO DATA ROOM ON
ASSOCIATED FLOOR. PROVIDE CAT-6 CABLE TO EACH DATA OUTLET LOCATION
SHOWN WITHIN UNIT. SEE DETAIL #6 ON SHEET E-501.
17 PORCH LIGHT AND ASSOCIATED SWITCH TO BE INCLUDED ON GROUND FLOOR UNITS
ONLY.
# DESCRIPTION DATE
1 ASI-01 12/14/2020
10/11/21