HomeMy WebLinkAboutE403 - ENLARGED ELECTRICAL PLANSS S SS SS C1 BALCONY 54 SQ FT S S S SS SCFB LF4 CFB LF5 LF1LF1 LF4 LF4 LF5 LF5 LF1 LF1 LF1 LF1 LF1 LF1 LF1 LF1 LF1 LF1 LF1 LF1 LF1 LF1 S S S S S SFCU-3 18,20 WH-3 13,15 CU-3 12,14 10 10 10 A5 3 A5 3 A5 3 23 6 6 6 9,1114 A1 3 A1 3 A5 3 7 7 7 4 4 A1 4 A1 4 A1 3 A1 3 A1 3 22 17,19 16 16 16 5 4 PNL-C123 10 9 9 9 10 10 12 15 3 7 13 2 1 14 14 14 14 14 11 5 8 8 B C C 8 A 11 11 10 10 23 23 23 23 16 6 6 7 7 7 1 8 16 16 A1 3 A1 3 A1 3 A4 4 A4 4 A4 4 A1 4 A3 3 B I 8 E G O P WP 63 A6 2 17 F 6 A1 3 M A1 3 4 C A1 3 A1 3 P FCU-3 17,19 WH-3 13,15 CU-3 10,12 8 8 8 A5 4 A5 4 A5 4 6 6 6 9,11 A5 4 20 20 20 7 14,16 22 23 23 23 2 3 3 A1 3 A1 3 A1 4 A1 4 PNL-C1A23 2 18 3 18 18 8 9 9 9 10 1012 15 3 7 2 1 14 14 14 14 11 5 8 8 16 P A B B C C 11 8 8 11 18 18 3 A 6 6 14 6 20 20 5 23 23 23 11 A1 3 A4 3 A4 33 A1 3 A4 3 A4 3 8 A3 4 A1 4 A1 4 A1 4 A1 4 A1 4 A1 4 A1 4 A1 4 G M Q I 13 6 WP 6 A6 4 F E N 1 3 4 A1 4 A1 4 FCU-3 18,20 WH-3 14,16 CU-3 13,15 11 11 A5 3 A5 3 A5 3 5 5 5 10,12 A5 3 8 8 8 4 17,19 22 66 7 2 24 A1 24 A1 2 A1 3 A1 3 PNL-C26 20 21 11 9 9 9 10 10 12 15 3 7 13 2 1 14 14 1414 14 11 5 8 8 8 16 8 P A B C 11 11 11 11 21 21 21 21 11 B 1 2 5 C 6 6 9 8 A3 3 A1 3 A1 3 A1 3 A1 3A1 3 A1 3 A1 3 A1 3 A1 3 A1 2 A1 3 A1 3 5 8 8 5 A1 3 A4 24 A4 2 A4 2 G E M Q 6 6 11 8 WP A4 3 17 I F 21 24 P C ARCHITECTCLIENT CONSULTANT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONSKBSO Consulting1344 S Rangeline Rd. Suite 202CARMEL, INDIANA 46032P: 317-344-8044PERMIT SET APRIL 28TH, 2021 20005THE AVANTPHASE IIE403ENLARGEDELECTRICAL PLANSCARMEL,IN1/4" = 1'-0" ENLARGED UNIT C1 ELECTRICAL PLAN 1 1/4" = 1'-0" ENLARGED UNIT C1a ELECTRICAL PLAN2 1/4" = 1'-0" ENLARGED UNIT C2 ELECTRICAL PLAN3 GENERAL NOTES A REFER TO SHEET E-000 FOR GENERAL ELECTRICAL NOTES, SYMBOLS AND ABBREVIATIONS. B REFER TO SHEET E601 FOR LIGHT FIXTURE SCHEDULE. C REFER TO E600 SERIES SHEETS FOR LOAD CENTER CIRCUIT SCHEDULES FOR EACH DWELLING UNIT TYPE. D ELECTRICAL LAYOUTS SHOWN SHALL BE TYPICAL FOR EACH RESIDENTIAL UNIT TYPE IDENTIFIED UNLESS NOTED OTHERWISE. E LIGHT FIXTURE LOCATIONS SHOWN SHALL BE SUPERCEDED BY THE ARCHITECTURAL REFLECTED CEILING PLANS. F INSTALL MULTIPLE SWITCHES SHOWN IN SINGLE LOCATION BEHINE A SINGLE MULTI-GANG SWITCH FACEPLATE. INSTALL A MAXIMUM OF FOUR (4) SWITCHES BEHIND A SINGLE SWITCH FACEPLATE. G CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF MECHANICAL EQUIPMENT WITH THE MECHANICAL CONTRACTOR. EXACT ELECTRICAL REQUIREMENTS SHALL BE FIELD VERIFIED AGAINST THE EQUIPMENT NAME PLATE DATA. THE CONTRACTOR SHALL MAKE APPROPRIATE ADJUSTMENTS OF FEEDER CIRCUIT CONDUCTORS AND OVERCURRENT PROTECTION PER MANUFACTURER. H ALL RECEPTACLES LOCATED IN KITCHENS AND BATHROOMS SHALL BE GFCI TYPE. I LOAD CENTERS FOR EACH DWELLING UNIT SHALL BE RECESSED IN WALL AS INDICATED. LOAD CENTER SHALL NOT BE INSTALLED IN DEMISING WALL. J PROVIDE DUPLEX RECEPTACLE ON DEDICATED CIRCUIT IN HOMENETWORKING CABINET. K ALL SMOKE ALARM DEVICES WITHIN EACH DWELLING UNIT SHALL BE INTERCONNECTED AND ONLY ALARM WITHIN THE DWELLING UNIT THEY RESIDE. L THE BUILDING FIRE ALARM CONTROL PANEL SHALL MONITOR THE STATUS OF EACH SMOKE ALARM UNIT WITHIN EACH DWELLING UNIT. M DWELLING UNIT SMOKE ALARM DEVICES SHALL BE POWERED BY THE BUILDING FIRE ALARM SYSTEM. N PROVIDE LOW FREQUENCY SOUNDER BASE WITHIN EACH SLEEPING AREA AND LIVING AREA ON EACH DWELLING UNIT TYPE. AUDIBLE DEVICES SHALL ALARM UPON ACTIVATION OF BUILDING FIRE ALARM SYSTEM AND DWELLING UNIT SMOKE ALARM DEVICES. O DWELLING UNITS NOTED AS ADA ACCESSIBLE SHALL BE EQUIPPED WITH FIRE ALARM VISUAL DEVICES WITHIN BEDROOMS, BATHROOMS AND COMMON LIVING AREA. P DWELLING UNITS NOTED AS ADA ACCESSIBLE ELECTRICAL PANELS SHALL BE MOUNTED SO AS THE HIGHEST BREAKER IS NO HIGHER THAN 48" ABOVE FINISHED FLOOR. SHEET KEYNOTES 1 WASHER CONNECTION.FURNISH AND INSTALL A NEMA 5-20R RECEPTACLE (2) #12 AND (1) #12GND. COORDINATE EXACT REQUIREMENTS WITH EQUIPMENT INSTALLED. 2 DRYER CONNECTION .FURNISH AND INSTALL RECEPTACLE.(3) #10 AND (1) #10GND.VERIFY FINAL RECEPTACLE TYPE AND EXACT REQUIREMENTS WITH EQUIPMENT INSTALLLER PRIOR TO INSTALLATION. 3 RANGE/OVEN CONNECTION.FURNISH AND INSTALL RECEPTACLE (3) #6 AND 1 #10 GND.VERIFY FINAL RECEPTACLE TYPE AND EXACT REQUIREMENTS WITH EQUIPMENT INSTALLER PRIOR TO INSTALLATION. 4 MOUNT RECEPTACLE 48" AFF FOR REFRIGERATOR 5 PROVIDE DEDICATED GFI RECEPTACLE AND WALL SWITCH FOR DISPOSAL 6 PROVIDE DEDICATED DUPLEX GFI RECEPTACE FOR DISHWASHER 7 MICROWAVE/HOOD CONNECTION.FURNISH AND INSTALL A NEMA 5-20R RECEPTACLE IN AND (2) #12 AND (1) #12 GND. COORDINATE EXACT REQUIREMENTS WITH EQUIPMENT INSTALLER FOR ANSI UNITS,PROVIDE JUNCTION BOX FOR AND AN ABOVE COUNTER RECEPTACLE FOR COUNTER TOP MICR 8 SPLIT WIRED RECEPTACLE .WIRE TOP OUTLET TO WALL SWITCH AT ROOM ENTRY. 9 PROVIDE FAN RATED JUNCTION BOX FLUSH MOUNTED IN THE CEILING FOR CEILING FAN 10 PROVIDE 120V CONNECTION TO BATHROOM EXHAUST FAN .PROVIDE WALL SWITCH FOR CONTROL AND CONNECT LIGHTING TO CIRCUIT. 11 MOUNT TV RECEPTACLE AND DATA OUTLET IN LINE WITH EACH OTHER. EACH DATA OUTLET TO CONSIST OF (1) RJ45 DATA JACK AND (1) COAX JACK BEHIND COMMON WALLPLATE .PROVIDE COAX HOMERUN TO DATA ROOM ON ASSOCIATED FLOOR. PROVIDE CAT-6 FROM DATA JACK TO 5 -PORT SWITCH IN UNIT LAUNDRY ROOM. 12 PROVIDE NON FUSED DISCONNECT AND 208 V .1-PH.30 a CIRCJIT FOR ELECTRICAL WATER HEATER,USE (2) AND (1) #GND. 13 PROVIDE NON FUSED DISCONNECT AND 208 V,1 PH POWER CIRCUIT FOR CU UNIT LOCATED ON ROOF.USE (2) #10 AND (1) #10 GND. 14 FURNISH AND INSTALL SMOKE DETECTIONB DEVICES AS SHOWN ON PLAN .SMOKE DETECTOR WITH SOUNDER BASE CONNECTED TO UNSWITCHED HOT CONDUCTOR IN CIRCUIT. BUILT IN STROBES IN HANDI-CAP UNITS THAT ARE FOR VISUALLY/hEARING IMPAIRED . TYPICAL 15 PROVIDE NON FUSED DISCONNECT AND 208 V,1 PH ,35 A CIRCUIT FOR FCU-1. USE (2) #10 AND (1) #10 GND. 16 PROVIDE DUPLEX RECEPTACLE AND DATA OUTLET MOUNTED AT +90". PROVIDE (5) PORT DATA SWITCH MOUNTED ABOVE RECEPTACLE AND DATA OUTLET.USE MIKROTIK RB260GS SWITCH OR OWNER APPROVED EQUAL.DATA OUTLET TO HAVE (6) RJ45 PORTS BEHIND SINGLE WALL PLATE.PROVIDE CAT-6 HOME RUN TO DATA ROOM ON ASSOCIATED FLOOR. PROVIDE CAT-6 CABLE TO EACH DATA OUTLET LOCATION SHOWN WITHIN UNIT. SEE DETAIL #6 ON SHEET E-501. 17 PORCH LIGHT AND ASSOCIATED SWITCH TO BE INCLUDED ON GROUND FLOOR UNITS ONLY. SWITCHING SCHEDULE TYPE 1ST SWITCH FUNCTION 1ST SWITCH TYPE 2ND SWITCH FUNCTION 2ND SWITCH TYPE 3RD SWITCH FUNCTION 3RD SWITCH TYPE 4TH SWITCH FUNCTION 4TH SWITCH TYPE A BEDROOM "A5" FIXTURE DUAL SLIDE SWITCH FOR SEPERATE FAN AND LIGHT CONTROL BEDROOM SWITCHED RECEPTACLE SNAP B BATHROOM FIXTURES SNAP BATHROOM EXHAUST SNAP C CLOSET "A1" FIXTURE SNAP D DINING ROOM "A3" FIXTURE SNAP HALLWAY "A1" FIXTURE SNAP E KITCHEN "A1" FIXTURES SNAP KITCHEN ISLAND "A1" FIXTURES SNAP F PORCH "A6" FIXTURE SNAP LIVING ROOM "A5" FIXTURE DUAL SLIDE SWITCH FOR SEPERATE FAN AND LIGHT CONTROL LIVING ROOM SWITCHED RECEPTACLE SNAP G ENTRY "A1" FIXTURE(S) SNAP H LAUNDRY/MECHANICAL ROOM "A1" FIXTURE SNAP I DINING ROOM "A3" FIXTURE SNAP J PORCH "A6" FIXTURE SNAP K ENTRY "A1" FIXTURE(S) SNAP KITCHEN "A1" FIXTURES SNAP KITCHEN ISLAND "A1" FIXTURES SNAP L LIVING ROOM "A5" FIXTURE DUAL SLIDE SWITCH FOR SEPERATE FAN AND LIGHT CONTROL LIVING ROOM SWITCHED RECEPTACLE SNAP M HALLWAY "A1" FIXTURE(S) SNAP N BATHROOM FIXTURES 3-WAY SNAP O ENTRY "A1" FIXTURE(S) 3-WAY SNAP P BEDROOM "A5" FIXTURE DUAL SLIDE SWITCH FOR SEPERATE FAN AND LIGHT CONTROL BEDROOM SWITCHED RECEPTACLE SNAP BEDROOM "A1" FIXTURE SNAP Q HALLWAY "A1" FIXTURE(S) 3-WAY SNAP # DESCRIPTION DATE 1 ASI-01 12/14/2020 10/11/21