20005THE AVANTPHASE IIE602ELECTRICALSCHEDULES CARMEL,INDEMAND FACTORS AND DIVERSITIES CALCULATED ACCORDING TO NEC 220.82
Notes:
Total Est. Demand: 127 A
HVAC NON-COINCIDENTAL 2496 VA 100.00% 2496 VA Total Conn.: 155 A
Dwelling Unit Load 19670 VA 70.50% 13868 VA Total Est. Demand: 26342 VA
LIGHTING 23 VA 125.00% 29 VA Total Conn. Load: 32138 VA
HVAC 4909 VA 100.00% 4909 VA
Load Classification Connected Load Demand Factor Estimated... Panel Totals
Total Amps: 166 A 139 A
Total Load: 17676 VA 14462 VA
29 SPARE 20 A 1 0 VA SPARE 30
27 SPARE 20 A 1 0 VA 0 VA SPARE 28
25 SPARE 20 A 1 0 VA 0 VA SPARE 26
23 SPARE 20 A 1 0 VA 0 VA SPARE 24
21 SPARE 20 A 1 0 VA 0 VA SPARE 22
19 RECEPT-LIVING ROOM 20 A 1 900 VA 20
17 RECEPT-KITCHEN 20 A 1 900 VA 0 VA Dwelling Unit Load 18
15 2454... 4000... 16
13 FCU-1 30 A 2 2454... 2454... RANGE 14
11 1500... 2250... 12
9 DRYER 30 A 2 1500... 1500... WH-1 10
7 REFRIGERATOR 20 A 1 1000... 1248... 8
5 WASHER 20 A 1 1500... 0 VA CU-1 6
3 BATHROOM LIGHTING 20 A 1 210 VA 900 VA RECEPT-BEDROOM 4
1 LIGHTING 20 A 1 23 VA 0 VA DISPOSAL 2
CKT Circuit Description Trip Poles A B Circuit Description CKT
Enclosure: NEMA 1 MCB Rating: 200 A
Mounting: RECESSED Wires: 3 Mains Rating: 200 A
Supply From: METER Phases: 1 Mains Type: MCB
Location: MULTIPLE Volts: 120/208 Single A.I.C. Rating: 18KA
Branch Panel:PNL-A1
DEMAND FACTORS AND DIVERSITIES CALCULATED ACCORDING TO NEC 220.82
Notes:
Total Est. Demand: 150 A
HVAC NON-COINCIDENTAL 3744 VA 100.00% 3744 VA Total Conn.: 180 A
Dwelling Unit Load 20640 VA 69.07% 14256 VA Total Est. Demand: 31126 VA
LIGHTING 323 VA 125.00% 404 VA Total Conn. Load: 37429 VA
HVAC 7322 VA 100.00% 7322 VA
Load Classification Connected Load Demand Factor Estimated... Panel Totals
Total Amps: 177 A 182 A
Total Load: 18446 VA 18983 VA
29 SPARE 20 A 1 0 VA 30
27 SPARE 20 A 1 0 VA 0 VA SPARE 28
25 SPARE 20 A 1 0 VA 0 VA SPARE 26
23 SPARE 20 A 1 0 VA 0 VA SPARE 24
21 DISHWASHER 20 A 1 1500... 0 VA SPARE 22
19 RECEPT-BEDROOM 20 A 1 900 VA 1000... REFRIGERATOR 20
17 MICROWAVE 20 A 1 1000... 0 VA RECEPT-DATA 18
15 3661... 4000... 16
13 FCU-2 50 A 2 3661... 3661... RANGE 14
11 1872... 2250... 12
9 CU-2 25 A 2 1872... 1872... WH-2 10
7 RECEPT-LIVING ROOM 20 A 1 1080... 1500... 8
5 RECEPT-BEDROOM 20 A 1 900 VA 0 VA DRYER 6
3 BATHROOM LIGHTING 20 A 1 420 VA 800 VA DISPOSAL 4
1 LIGHTING 20 A 1 323 VA 0 VA RECEPT-HALLWAY/KITCHEN 2
CKT Circuit Description Trip Poles A B Circuit Description CKT
Enclosure: NEMA 1 MCB Rating: 200 A
Mounting: RECESSED Wires: 3 Mains Rating: 200 A
Supply From: METER Phases: 1 Mains Type: MCB
Location: MULTIPLE Volts: 120/208 Single A.I.C. Rating: 18KA
Branch Panel:PNL-B2
DEMAND FACTORS AND DIVERSITIES CALCULATED ACCORDING TO NEC 220.82
Notes:
Total Est. Demand: 149 A
HVAC NON-COINCIDENTAL 3744 VA 100.00% 3744 VA Total Conn.: 182 A
Dwelling Unit Load 21350 VA 68.10% 14540 VA Total Est. Demand: 31050 VA
LIGHTING 323 VA 125.00% 404 VA Total Conn. Load: 37779 VA
HVAC 7322 VA 100.00% 7322 VA
Load Classification Connected Load Demand Factor Estimated... Panel Totals
Total Amps: 179 A 184 A
Total Load: 18603 VA 19176 VA
29 SPARE 20 A 1 0 VA SPARE 30
27 SPARE 20 A 1 0 VA 0 VA SPARE 28
25 SPARE 20 A 1 0 VA 0 VA 26
23 RECEPT-LIVING ROOM 20 A 1 900 VA 1500... WASHER 24
21 RECEPT-BEDROOM 20 A 1 900 VA 0 VA MICROWAVE 22
19 3661... 4000... 20
17 FCU-2 50 A 2 3661... 3661... RANGE 18
15 1872... 2250... 16
13 CU-2 25 A 2 1872... 1872... WH-2 14
11 RECEPT-KITCHEN/HALLWAY 20 A 1 1260... 1500... 12
9 DISHWASHER 20 A 1 1500... 0 VA DRYER 10
7 DISPOSAL 20 A 1 800 VA 900 VA RECEPT-BEDROOM 8
5 BATHROOM LIGHTING 20 A 1 240 VA 0 VA REFRIGERATOR 6
3 BATHROOM LIGHTING 20 A 1 210 VA 323 VA LIGHTING 4
1 LIGHTING 20 A 1 0 VA 0 VA RECEPT-DATA 2
CKT Circuit Description Trip Poles A B Circuit Description CKT
Enclosure: NEMA 1 MCB Rating: 200 A
Mounting: RECESSED Wires: 3 Mains Rating: 200 A
Supply From: METER Phases: 1 Mains Type: MCB
Location: MULTIPLE Volts: 120/208 Single A.I.C. Rating: 18KA
Branch Panel:PNL-B1
DEMAND FACTORS AND DIVERSITIES CALCULATED ACCORDING TO NEC 220.82
Notes:
Total Est. Demand: 165 A
HVAC NON-COINCIDENTAL 3536 VA 100.00% 3536 VA Total Conn.: 201 A
Dwelling Unit Load 22460 VA 66.71% 14984 VA Total Est. Demand: 34418 VA
LIGHTING 323 VA 125.00% 404 VA Total Conn. Load: 41814 VA
HVAC 9734 VA 100.00% 9734 VA
Load Classification Connected Load Demand Factor Estimated... Panel Totals
Total Amps: 210 A 188 A
Total Load: 22225 VA 19588 VA
29 SPARE 20 A 1 0 VA SPARE 30
27 SPARE 20 A 1 0 VA 0 VA SPARE 28
25 SPARE 20 A 1 0 VA 0 VA SPARE 26
23 RECEPT-KITCHEN 20 A 1 1260... 24
21 0 VA MICROWAVE 22
19 4867... 900 VA RECEPT-LIVING ROOM 20
17 FCU-3 50 A 2 4867... 4867... RECEPT-BEDROOM 18
15 2250... 4000... 16
13 WH-3 30 A 2 2250... 2250... RANGE 14
11 1500... 1768... 12
9 DRYER 30 A 2 1500... 1500... CU-3 10
7 DISPOSAL 20 A 1 800 VA 1080... RECEPT-BEDROOM 8
5 DISHWASHER 20 A 1 1500... 0 VA RECEPT-BEDROOM 6
3 BATHROOM 20 A 1 840 VA 323 VA LIGHTING 4
1 RECEPT-DATA 20 A 1 180 VA 0 VA WASHER 2
CKT Circuit Description Trip Poles A B Circuit Description CKT
Enclosure: NEMA 1 MCB Rating: 200 A
Mounting: RECESSED Wires: 3 Mains Rating: 200 A
Supply From: METER Phases: 1 Mains Type: MCB
Location: MULTIPLE Volts: 120/208 Single A.I.C. Rating: 18KA
Branch Panel:PNL-C1A
DEMAND FACTORS AND DIVERSITIES CALCULATED ACCORDING TO NEC 220.82
Notes:
Total Est. Demand: 165 A
HVAC NON-COINCIDENTAL 3536 VA 100.00% 3536 VA Total Conn.: 198 A
Dwelling Unit Load 21630 VA 67.74% 14652 VA Total Est. Demand: 34346 VA
LIGHTING 323 VA 125.00% 404 VA Total Conn. Load: 41244 VA
HVAC 9734 VA 100.00% 9734 VA
Load Classification Connected Load Demand Factor Estimated... Panel Totals
Total Amps: 205 A 190 A
Total Load: 21525 VA 19718 VA
29 SPARE 20 A 1 0 VA 30
27 SPARE 20 A 1 0 VA 0 VA SPARE 28
25 SPARE 20 A 1 0 VA 0 VA SPARE 26
23 RECEPT-BEDROOM 20 A 1 1080... 0 VA SPARE 24
21 SPARE 20 A 1 0 VA 0 VA MICROWAVE 22
19 4000... 4867... 20
17 RANGE 50 A 2 4000... 4000... FCU-3 18
15 2250... 900 VA RECEPT-KITCHEN 16
13 WH-3 30 A 2 2250... 2250... 14
11 1500... 1768... CU-3 12
9 DRYER 30 A 2 1500... 1500... RECEPT-BEDROOM 10
7 RECEPT-LIVING ROOM/HALLWAY 20 A 1 1080... 1500... DISHWASHER 8
5 REFRIGERATOR 20 A 1 1000... 0 VA RECEPT-BEDROOM 6
3 LIGHTING 20 A 1 323 VA 450 VA BATHROOM LIGHTING 4
1 RECEPT-DATA 20 A 1 180 VA 0 VA DISPOSAL 2
CKT Circuit Description Trip Poles A B Circuit Description CKT
Enclosure: NEMA 1 MCB Rating: 200 A
Mounting: RECESSED Wires: 3 Mains Rating: 200 A
Supply From: METER Phases: 1 Mains Type: MCB
Location: MULTIPLE Volts: 120/208 Single A.I.C. Rating: 18KA
Branch Panel:PNL-C1
DEMAND FACTORS AND DIVERSITIES CALCULATED ACCORDING TO NEC 220.82
Notes:
Total Est. Demand: 130 A
HVAC NON-COINCIDENTAL 2496 VA 100.00% 2496 VA Total Conn.: 160 A
Dwelling Unit Load 20530 VA 69.23% 14212 VA Total Est. Demand: 27061 VA
LIGHTING 323 VA 125.00% 404 VA Total Conn. Load: 33298 VA
HVAC 4909 VA 100.00% 4909 VA
Load Classification Connected Load Demand Factor Estimated... Panel Totals
Total Amps: 167 A 151 A
Total Load: 17592 VA 15706 VA
29 SPARE 20 A 1 0 VA SPARE 30
27 SPARE 20 A 1 0 VA 0 VA SPARE 28
25 SPARE 20 A 1 0 VA 0 VA SPARE 26
23 MICROWAVE 20 A 1 1500... 0 VA SPARE 24
21 SPARE 20 A 1 0 VA 0 VA DISHWASHER 22
19 RECEPT-LIVING ROOM 20 A 1 720 VA 1500... WASHER 20
17 RECEPT-KITCHEN 20 A 1 1080... 0 VA REFRIGERATOR 18
15 2454... 4000... 16
13 FCU-1 30 A 2 2454... 2454... RANGE 14
11 1500... 2250... 12
9 DRYER 30 A 2 1500... 1500... WH-1 10
7 1248... 8
5 RECEPT-BEDROOM 20 A 1 1080... CU-1 6
3 LIGHTING 20 A 1 210 VA 323 VA LIGHTING 4
1 RECEPT-DATA 20 A 1 180 VA 0 VA DISPOSAL 2
CKT Circuit Description Trip Poles A B Circuit Description CKT
Enclosure: NEMA 1 MCB Rating: 200 A
Mounting: RECESSED Wires: 3 Mains Rating: 200 A
Supply From: METER Phases: 1 Mains Type: MCB
Location: MULTIPLE Volts: 120/208 Single A.I.C. Rating: 18KA
Branch Panel:PNL-A2
DEMAND FACTORS AND DIVERSITIES CALCULATED ACCORDING TO NEC 220.82
Notes:
Total Est. Demand: 148 A
HVAC NON-COINCIDENTAL 3744 VA 100.00% 3744 VA Total Conn.: 182 A
Dwelling Unit Load 22070 VA 67.19% 14828 VA Total Est. Demand: 30798 VA
LIGHTING 323 VA 125.00% 404 VA Total Conn. Load: 37959 VA
HVAC 7322 VA 100.00% 7322 VA
Load Classification Connected Load Demand Factor Estimated... Panel Totals
Total Amps: 182 A 183 A
Total Load: 18923 VA 19036 VA
29 SPARE 20 A 1 0 VA 30
27 SPARE 20 A 1 0 VA 0 VA SPARE 28
25 SPARE 20 A 1 0 VA 0 VA SPARE 26
23 BATHROOM-LIGHTING 20 A 1 210 VA 0 VA SPARE 24
21 MICROWAVE 20 A 1 1500... 0 VA SPARE 22
19 4000... 900 VA RECEPT-BEDROOM 20
17 RANGE 50 A 2 4000... 4000... RECEPT-BEDROOM 18
15 2250... 3661... 16
13 WH-2 20 A 2 2250... 2250... FCU-2 14
11 1500... 1872... 12
9 DRYER 30 A 2 1500... 1500... CU-2 10
7 RECEPT-LIVING ROOM 20 A 1 900 VA 1500... DISHWASHER 8
5 REFRIGERATOR 20 A 1 1000... 0 VA RECEPT-HALLWAY/KITCHEN 6
3 LIGHTING 20 A 1 503 VA 240 VA BATHROOM LIGHTING 4
1 RECEPT-DATA 20 A 1 180 VA 0 VA DISPOSAL 2
CKT Circuit Description Trip Poles A B Circuit Description CKT
Enclosure: NEMA 1 MCB Rating: 200 A
Mounting: RECESSED Wires: 3 Mains Rating: 200 A
Supply From: METER Phases: 1 Mains Type: MCB
Location: MULTIPLE Volts: 120/208 Single A.I.C. Rating: 18KA
Branch Panel:PNL-B3
DEMAND FACTORS AND DIVERSITIES CALCULATED ACCORDING TO NEC 220.82
Notes:
Total Est. Demand: 164 A
HVAC NON-COINCIDENTAL 3536 VA 100.00% 3536 VA Total Conn.: 200 A
Dwelling Unit Load 22790 VA 66.33% 15116 VA Total Est. Demand: 34010 VA
LIGHTING 323 VA 125.00% 404 VA Total Conn. Load: 41604 VA
HVAC 9734 VA 100.00% 9734 VA
Load Classification Connected Load Demand Factor Estimated... Panel Totals
Total Amps: 202 A 198 A
Total Load: 21045 VA 20558 VA
29 30
27 28
25 26
23 SPARE 20 A 1 0 VA 210 VA BATHROOM 24
21 RECEPT-BEDROOM 20 A 1 1080... 0 VA MICROWAVE 22
19 4000... 4867... 20
17 RANGE 50 A 2 4000... 4000... FCU-3 18
15 1768... 2250... 16
13 CU-3 25 A 2 1768... 1768... WH-3 14
11 RECEPT-BEDROOM 20 A 1 1080... 1500... 12
9 DISHWASHER 20 A 1 1500... 0 VA DRYER 10
7 REFRIGERATOR 20 A 1 1000... 1260... RECEPT-LIVING ROOM 8
5 RECEPT-BEDROOM 20 A 1 1080... 0 VA RECEPT-KITCHEN 6
3 LIGHTING 20 A 1 323 VA 800 VA DISPOSAL 4
1 RECEPT-DATA 20 A 1 180 VA 0 VA BATHROOM 2
CKT Circuit Description Trip Poles A B Circuit Description CKT
Enclosure: NEMA 1 MCB Rating: 200 A
Mounting: RECESSED Wires: 3 Mains Rating: 200 A
Supply From: METER Phases: 1 Mains Type: MCB
Location: MULTIPLE Volts: 120/208 Single A.I.C. Rating: 18KA
Branch Panel:PNL-C2
# DESCRIPTION DATE
DEMAND FACTORS AND DIVERSITIES CALCULATED ACCORDING TO NEC 220.82
Notes:
Total Est. Demand: 127 A
HVAC NON-COINCIDENTAL 2496 VA 100.00% 2496 VA Total Conn.: 155 A
Dwelling Unit Load 19850 VA 70.23% 13940 VA Total Est. Demand: 26414 VA
LIGHTING 23 VA 125.00% 29 VA Total Conn. Load: 32318 VA
HVAC 4909 VA 100.00% 4909 VA
Load Classification Connected Load Demand Factor Estimated... Panel Totals
Total Amps: 138 A 168 A
Total Load: 14328 VA 17990 VA
29 SPARE 20 A 1 0 VA 30
27 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 28
25 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 26
23 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 24
21 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 22
19 CU-1 30 A 1 2496... 2454... 20
17 2250... 2454... 2 30 A FCU-1 18
15 WH-1 30 A 2 2250... 1500... 16
13 WASHER 20 A 1 1500... 1500... 2 30 A DRYER 14
11 REFRIGERATOR 20 A 1 1000... 1500... 1 20 A DISHWASHER 12
9 4000... 800... 1 20 A DISPOSAL 10
7 RANGE 50 A 2 4000... 1500... 1 20 A MICROWAVE 8
5 RECEPT-KITCHEN 20 A 1 360... 360... 1 20 A RECEPT-KITCHEN 6
3 BATHROOM LIGHTING 20 A 1 210... 1080... 1 20 A RECEPT-LIVING ROOM/HALLWAY 4
1 RECEPT-BEDROOM 20 A 1 900... 203... 1 20 A LIGHTING 2
CKT Circuit Description Trip Poles A B Poles Trip Circuit Description CKT
Enclosure: NEMA 1 MCB Rating: 200 A
Mounting: RECESSED Wires: 3 Mains Rating: 200 A
Supply From: METER Phases: 1 Mains Type: MCB
Location: MULTIPLE Volts: 120/208 Single A.I.C. Rating: 18KA
Branch Panel:PNL-A1a
10/11/21